Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.com
Tesira
®
TEC-1s & TEC-1i
Operation/Installation
Manual
October 2012
Страница 1: ...Biamp Systems 9300 SW Gemini Drive Beaverton Oregon 97008 U S A 503 641 7287 www biamp com Tesira TEC 1s TEC 1i Operation Installation Manual October 2012 ...
Страница 2: ...vice Setup Mode 6 Edit Device ID 7 Edit Network Configuration 7 Edit Unlock Code 8 Edit Display Brightness 8 Edit Timeouts 8 View Device Information 9 Reset to Factory Defaults 9 Exit 9 INSTALLATION 10 13 TEC 1s Surface Mount Installation 10 TEC 1i Flush Mount Installation 11 Wiring 13 SPECIFICATIONS 14 WARRANTY 15 FCC COMPLIANCE 16 EC DECLARATION 17 EU RoHS COMPLIANCE 18 ...
Страница 3: ...combining etc Control functions are programmed in the Tesira system design software High contrast OLED Organic Light Emitting Diode display with a wide viewing angle The display brightness can be adjusted to fit the ambient light present in the application and can auto matically dim when not in use Capacitive touch technology eliminates protruding and moving parts to increase product reliability a...
Страница 4: ... background shows a list of all control items available from that panel as well as the last selected item If a control item includes a volume control assignment the bottom of the display will show a graphical representation of a volume bar with the current level indicated to the right percentage of maximum level Capacitive touch Scroll Wheel The capacitive touch sensor provides a sleek interface f...
Страница 5: ...a Tesira system This connection is made to the Ethernet port of a Tesira unit either directly single station or via a network switch and carries control data over Ethernet The TEC 1 is powered using IEEE 802 3 2008 Power over Ethernet protocol as Class 1 devices Either a PoE capable network switch or a PoE injector is required to power the device there are no other provisions for power inlet TEC 1...
Страница 6: ...ailable items in the list the gray box will highlight the current selection On fields that can be modified use the Select button to transition to and from modify mode In modify mode the cursor appears as an outline box Use the scroll wheel to adjust the setting up or down Some screens have additional buttons that are used to accept OK reset or cancel changed settings Use the scroll wheel to naviga...
Страница 7: ... configuration scroll to the Network icon and press the Select button The default setting Auto allows the device to receive its network configuration from a DHCP server This allows TEC 1 to be discovered by a Tesira device that also has default settings The default hostname is TEC 1 followed by its serial number Select the hostname to edit it in a similar way of editing the device ID The network s...
Страница 8: ...the Display Brightness icon and press the Select button Use the scroll wheel and Select button to make adjustments The first setting represents the normal opera tional display brightness and the second setting represents the dim display brightness Display brightness cannot be assigned via Device Maintenance in the Tesira software Edit Timeouts To change the lock dim and sleep timeouts scroll to th...
Страница 9: ...omatically to indicate what IP address it received Use the scroll wheel to navigate through the list of information Press the Select button to exit this screen Reset to Factory Defaults To reset to factory defaults scroll to the reset icon with the exclamation point and press the Select button To confirm scroll to the Yes button and press the Select button Otherwise selecting No will return back t...
Страница 10: ...the TEC 1s using the RJ45 connector guide the Ethernet cable through the rear opening before attaching the TEC 1s to the wall Connect the RJ45 and snap the front enclosure into the reten tion holes When installing the TEC 1s using the IDC use a drill bit to create a hole in the top side or rear of the back enclosure along the indentations Remove the Ethernet cable jacket and shielding 84mm 3 3 USA...
Страница 11: ...r a Raco 254 box purchased from an electrical distributor To install the TEC 1i a hole must be cut in the wall to accommodate the Raco 254 box or to use the retrofit plate See the figures below SECTION A A SECTION A A 11 75cm 12 07cm 4 5 8 4 3 4 Wall cut out dimensions Mounting using a Raco 254 box Mounting using the retrofit plate ...
Страница 12: ...f the front plate Once this has been done rotate the bottom of the front plate towards the bottom of the trim ring until it is seated in the trim ring via the bottom clip If the front plate needs to be removed use a screw driver or other suitable tool to engage the latch at the bottom of the TEC 1i to detach from the trim ring Refer to page 13 for instructions regarding the use of the insulation d...
Страница 13: ... tabs until the insulation is punctured with an audible click No wire stripping is necessary IDC wiring scheme Note the appropriate bend radius requirements for category cables as shown in the figure below Software support in Tesira configuration software Version 1 1 or later provides user programming of all remote functions network setup device naming and device maintenance Visit www biamp com to...
Страница 14: ...ard Ethernet network wiring Control programming Each control configured for specific operation by the system design software Compliance EU Directive 2002 95 EC RoHS Directive CE marked FCC TEC 1i SPECIFICATIONS Dimensions 6 22 H x 5 82 W x 0 5 D 158mm x 148mm x 12 7mm Power consumption PoE Class 1 3 2W full display utilization Control cable requirements Unshielded twisted pair UTP wiring 100BaseT ...
Страница 15: ...does not comply with Biamp Systems recommendations 4 Electro mechanical fans electrolytic capacitors gooseneck microphones cords connecting handheld microphones hard drives displays and normal wear and tear of items such as paint knobs handles keypads and covers are not covered under this warranty All server based devices are warranted for 3 years only 5 This warranty is in lieu of all other warra...
Страница 16: ...ructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to cor rect the interference by one or more of the following measures 1...
Страница 17: ...rds LVD Directive 2006 95 EC Safety EN 60065 2002 IEC 60065 2001 Amd 1 2005 EMC Directive 2004 108 EC Emissions EN 55103 1 1996 Environment E2 Immunity EN 55103 2 1996 Environment E2 RoHS Directive 2011 65 EU RoHS Recast Special Considerations for Product Environment or Compliance Use only PoE Insertion Devices that are CE Marked certified to local regulations and appropriately rated Type 1 PoE or...
Страница 18: ... 镉 Cr 6 六价铬 PBB PBDE 设备机箱 Equipment Chassis X O X O O O 手册和其他书面文档 Manual and Paper Documents O O O O O O 包装箱和所有包装材料 Box and Packing Materials O O O O O O 0 表示该部件所有均质材料中的这种有毒有害物质低于 SJ T11363 2006 的限制要求 X 表示该部件中至少有一种均质材料所含的这种有毒有害物质高于 SJ T11363 2006 的限制要求 在电触头和 或 镀镉所含的均质材料中 镉及其化合物的含量可以超过 0 01 但欧盟指令 91 338 EEC 根据欧盟指令 76 769 EEC 限制销售和使用某些危险物质和制剂部分中所禁止的用途除外 在以下一种或多种物质所含的均质材料中 铅及其化合物的含量可以超过 0 1 1 电子元器件中玻...