26
NSG 435 ESD simulator
The instrument is ready for use immediately after the execution of a self-test
and calibration procedure.
Press and hold the trigger button to activate the high voltage generation. The
active high voltage state is shown on the display by the “kV” indication blink-
ing.
The measured value of the breakdown voltage in air-discharge mode will be
displayed. Differentiation from the display of the set value is made by the frame
around the kV readings.
The effective discharge voltage depends on various factors such as the distance
to the discharge point, speed of approach, nature of the EUT, etc.
In the case of a contact-discharge this measurement is not carried out since
only a discharge current can occur.
The instrument switches itself off automatically after a period of 30 minutes
of non-use although the parameters that have been set will remain stored in
memory.