22
NSG 435 ESD simulator
The measurement adapter type MD 101 as per informative annex B of IEC/EN
61000-4-2 serves to verify pulse amplitudes and pulse shapes. It is designed for
mounting in the side wall of a Faraday cage in which an oscilloscope has been
installed. This measurement adapter, also known as a «Pellegrini-Target» has the
flat impedance curve to well over 1 GHz that is necessary for the purpose.
Use of this adapter is only worthwhile in conjunction with a test rig that is laid
out in strict conformity with the relevant standard (see section 7).
3.3.7 Measurement adapters
Coax connector
Contact surface
(target)
Mounting flange
MD 101
Designed as per
IEC/EN 61000-4-2:1995
MD 103 («Pommerenke» target) is a more advanced coaxial measuring target
with flat response characteristics up to the multi-GHz range. It may be used
instead of MD 101.