background image

 

TYPE - K.J.E.T. 

PRINTING  THERMOMETER

 

 

 

TES - 1304 

INSTRUCTION MANUAL 

 

 

TES ELECTRICAL ELECTRONIC CORP. 

 

Содержание TES-1304

Страница 1: ...TYPE K J E T PRINTING THERMOMETER TES 1304 INSTRUCTION MANUAL TES ELECTRICAL ELECTRONIC CORP...

Страница 2: ...NS 2 2 1 General Information 2 2 2 Electrical Specifications 4 III NAME OF PARTS AND POSITION 5 IV PRECAUTIONS AND PREPARATIONS FOR MEASUREMENT 10 V OPERATIONAL GUIDE 11 VI HOW TO SETUP INTERVAL PRINT...

Страница 3: ...nditions Altitude up to 2000 meters Indoor use only Relatively humidity 90 max Operation Temperature 0 50 32 122 Maintenance Clearing Repairs or servicing not covered in this manual should only be per...

Страница 4: ...KJET Type K J E T thermocouple HI ALARM Over high temp point LO ALARM Under Equal Low temp point Low battery symbol Negative polarity No symbol for positive polarity Celsius unit or Fahrenheit Printe...

Страница 5: ...e typ Approx 30 hours interval printing 60 minutes excluding beeper 70 hours without printing beeper Input protection 60Vdc 24Vrms Operating Temperature and Humidity 0 to 50 32 to 122 below 90 RH Stor...

Страница 6: ...below 80 RH Type K 0 01 rdg 0 5 0 982 0 05 rdg 0 5 982 1333 0 01 rdg 0 9 32 1800 0 05 rdg 0 9 1800 2431 Type J 0 01 rdg 0 5 0 760 0 01 rdg 0 9 32 1400 Type E 0 01 rdg 0 5 0 703 0 01 rdg 0 9 32 1297 Ty...

Страница 7: ...5 III NAME OF PARTS AND POSITION Fig 2 1 LCD Measured values unit symbols and decimal points are displayed 2 POWER Button for power on off 3 UNIT Button for exchanging temperature unit and...

Страница 8: ...rint current data Press this button for 2 seconds the printer will be set to interval printing status and won t stop unless this button is pressed again or FEED button is pressed 5 9V ADAPTOR SOCKET 3...

Страница 9: ...n5 will be in the low state Pin41 HiAlarm If the reading is higher than the high alarm point then pin 4 will be in high state otherwise in Low state Pin 51 LoAlarm If the reading is lower than equal t...

Страница 10: ...ding 1300 5 Result Hi Alarm output reading approx 5V Lo Alarm output reading approx 0V If LCD reading 50 5 Result Lo Alarm output reading approx 5V Hi Alarm output reading approx 0V Example Hi alarm 2...

Страница 11: ...meter Parameters in sequence K J E T type of thermocouple 00 01 interval printing enable or disable high low alarm temperature unit Hi Lo Alarm high low alarmpoint ranging frommeasure highest and meas...

Страница 12: ...rials until you are sure that this unit can normally operate 3 Be sure that batteries are correctly placed in the case or adaptive 9V Adaptor is in correct connection 4 An unsecured battery cover will...

Страница 13: ...r If appears it indicates no temperature probe or the probe is broken To enter test model before a version number After the power is on before entering measureing mode 16 will be shown on LCD C To sta...

Страница 14: ...399 LCD displays as Fig 8 Fig 8 5 LAST TWO DIGITS IN HI ALARM 00 99 LCD displays as Fig 9 Fig 9 6 FIRST THREE DIGITS IN LO ALARM 399 399 LCD displays as Fig 10 Fig 10 7 LAST TWO DIGITS IN LO ALARM 00...

Страница 15: ...LCD displays as Fig 13 Fig 13 10 SECOND OF INTERVAL PRINTING 00 59 LCD displays as Fig 14 Fig 14 11 HOUR OF START INTERVAL PRINTING TIME 00 23 LCD displays as Fig 15 Fig 15 12 MNUTE OF START INTERVAL...

Страница 16: ...UTEOFSTOPINTERVALPRINTINGTIME 00 59 LCD displays as Fig 18 Fig 18 15 FIRST TWO DIGITS OF CALENDAR YEAR 19 29 LCD displays as Fig 19 Fig 19 16 LAST TWO DIGITS OF CALENDAR YEAR 00 99 LCD displays as Fig...

Страница 17: ...lays as Fig 22 Fig 22 19 HOUR DIGITS OF CALENDAR HOUR MINUTE 00 23 LCD displays as Fig 23 Fig 23 20 MINUTE DIGITS OF CALENDAR HOUR MINUTE 00 59 LCD displays as Fig 24 Fig 24 21 SECOND DIGITS OF CALEND...

Страница 18: ...g time Line2 interval printing time hour minute second Following two lines Line1 hour minute second month day interval printing time Line2 measuring channel type value and unit Last two lines Line1 ho...

Страница 19: ...12 59 20 11 02 T1 K 0L First two lines Line1 hour minute second month day Line2 interval printing time hour minute second Following lines Line1 hour minute second month dat interval printing time Line...

Страница 20: ...gain to enter normal function The INTV symbol will be shown on LCD 2 Setup interval print without 24 hours limitation Entering Menu mode by pressing MENU button Disable Interval Print bit as described...

Страница 21: ...6 11 54 23 02 17 T2 K 0021 6 11 54 26 02 17 T12K 0000 0 VII BATTERY REPALCEMENT STEP 1 As battery power is not sufficient will be shown on LCD Replace with 6 pcs new of 1 5V size AAA batteries is req...

Страница 22: ...probe 50 to 1000 58 to 1832 2 2 or 0 75 3 6 or 0 75 3 2 150 Metal sheath 100 Compensating wire TP K03 Surface probe 50 to 750 58 to 1382 2 2 or 0 75 3 6 or 0 75 100 Compensating wire 12 5 94 handle TP...

Страница 23: ...ang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail Address tes ms9 hinet net Home page http www tes com tw Jan 2001 3 Import r Impex Produkter AS Gamle Drammensvei 107...