background image

T-SEAL

®

 III

Terumo Tube Sealing Device

Version  1.0 

Operator’s Manual

Содержание T-SEAL III

Страница 1: ...T SEAL III Terumo Tube Sealing Device Version 1 0 Operator s Manual...

Страница 2: ...UNLOCKING POTENTIAL TERUMOBCT COM Page 1 of 15 Version 1 0 Rev 02 2021 2021 Terumo BCT Inc T SEAL III Terumo Tube Sealing Device Operator s Manual...

Страница 3: ...on 10 Unpacking and Inspection 10 Environmental Requirements 10 3 1 Installation Procedure 10 Stand Alone Setup 10 Cascade Setup 10 4 Functional Description 11 4 1 Description of Sealing 11 5 Operatin...

Страница 4: ...be used Warning The device should not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary verify normal operation of the device in the configuration in which i...

Страница 5: ...ower switch off before disconnecting cables or cleaning Performance and Specifications The table below lists the physical specifications Specification type Value Terumo BCT catalog number T3828 Descri...

Страница 6: ...asic safety and essential performance EN 60601 1 2 2015 Collateral standards for Electromagnetic Compatibility Electrical safety Class I Waterproof IPX0 Not waterproof T SEAL III is used in the same e...

Страница 7: ...ctromagnetic Environment Guidance Electrostatic discharge ESD IEC 61000 4 2 8 kV contact 15 kV air 8 kV 15 kV Floors should be wood concrete or ceramic tile If floors are covered with synthetic materi...

Страница 8: ...the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromag...

Страница 9: ...ransmitters and T SEAL III For transmitters rated at a maximum output power the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the tra...

Страница 10: ...r FOLLOW INSTRUCTIONS Symbol for WARNING Symbol for SERIAL NUMBER Symbol for DATE OF MANUFACTURE Symbol for MANUFACTURER Storage conditions Symbol for TEMPERATURE Storage conditions Symbol for RELATIV...

Страница 11: ...5 C 32 F to 95 F and relative humidity 10 to 90 non condensing Handle the components with care in a clean environment 3 1 Installation Procedure Stand Alone Setup Preparing T SEAL III for use 1 Unfold...

Страница 12: ...by one 15 During the sealing process the LEDs will turn yellow on each device When the process is finished they will turn green again 16 Remove the tube when all the LEDs have turned green 4 Function...

Страница 13: ...se clean scissors to separate the tubing at the center of the seal Caution Do not make two or more seals within 1 cm 0 39 in of each other because the resulting pressure in the tube may cause microsco...

Страница 14: ...module Note The front cover can be cleaned separately Clean both electrodes with a soft lint free tissue moistened with a mild detergent Dry carefully and ensure that the electrodes are completely dry...

Страница 15: ...rkmanship when delivered to the original purchaser Terumo BCT s sole obligation shall be limited to repair or replacement at Terumo BCT s option and expense of the defective part or unit for the durat...

Страница 16: ...f written description of the problem should be attached to the instrument when it is returned for service Terumo BCT will not be responsible for unauthorized returns or for units damaged in shipment d...

Страница 17: ...Science Park Drive 04 25 Lobby B The Rutherford Singapore 118261 Phone 65 6715 3778 Fax 65 6774 1419 Terumo BCT Latin America S A La Pampa 1517 12t h Floor C1428DZE Buenos Aires Argentina Phone 54 11...