112
/
167
5.5.3.5
Attitude Calibration – Step 5
Now the calibration is completed.
Figure 150 Step 5 complete attitude calibration
5.5.3.6
After Calibration, Observe if the Calibrated Value is Correct
The calibration result is correct only if the value range of calibrated data is within ±5°.
If the calibration result is incorrect, eliminate the fault according to the following
procedures.
Perform attitude calibration again
Check if the self-checking status of equipment now is all green
Check if the vehicle now is on a flat ground and if the ground have excessive
inclination
Contact the distributor or the FAE department of the manufacturer.
When the attitude calibration is completed, enter “Calibration” menu again and the
attitude calibration icon now turns green.