Terra MR908L Скачать руководство пользователя страница 1

Multiswitches MR908L, MR912L, MR916L

Vers. 1.06

1

EN PL

EN

PRODUCT DESCRIPTION

This series of multiswitches has 8 satellite TV IF inputs, two terrestrial TV inputs (active and passive) and up to 16 subscriber's 

outputs. They ensure an independent access of every subscriber to any SAT IF or terrestrial input. 

Multiswitches are designed for use in large and medium SAT and terrestrial TV distribution systems.
Active terrestrial TV inp

ut has LTE signal suppression filter 

.

The housing of multiswitches meets more stringent screening requirements according to EN50083-2, class A.

The multiswitches are intended for indoor use only.

SAFETY INSTRUCTIONS

Installation of the multiswitches must be done according IEC60728-11 and national safety standards.

The multiswitch is powered from mains 230 V~. This voltage is dangerous to life. 

Any repairs must be done by a skilled personnel. 

The multiswitch is double isolated from the mains 230 V~.

Do not remove the cover of the power supply section, without disconnecting the unit from the mains supply. 

Do not plug the multiswitch into the mains supply if the power cord or plug is damaged.

Do not plug the multiswitch into the mains supply until all cables have been connected correctly.

The mains socket must be easily accessible.

The multiswitch shall not be exposed to dripping or splashing water.

Avoid placing multiswitch next to central heating components, near highly combustible materials and in areas of high humidity.

If the multiswitch has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before 

plugging into the mains.

Do not insert any objects into ventilation openings.

The ventilation should not be impeded by covering the multiswitch with items, such as newspapers, table-cloths, curtains.

Mount the multiswitch on not flammable wall or in not flammable installation box in vertical position with power supply unit 

on the right side. Mount in locations where children not likely to be present.

From top, front and bottom of installed multiswitch must be at least 10 cm free space.

WARNING!

 

Before connecting cables to multiswitch, be sure that cables shield and multiswitch functional grounding clamp 

have common potential. Otherwise, floating voltage can damage product. 

Shields of cables must be connected to main potential 

equalization bus.

MONTAGE VIEW

Mount the multiswitch in vertical position with RF input connectors on the left side. The multiswitch

 must be fixed with steel 

screws Ø 4-5 mm. The screws are not included in a package.

Check position of switch "Active Terr. DC 12V" to prevent shortcut of power supply, it must be "off" when preamplifier is absent.

OPERATING

SAT IF signals must be connected as shown on the label of multiswitch to ensure correct access to SAT TV signals. It is 

important to equalize average signal level from satellites. Use gain controls for each satellite line to achieve this goal.

The purpose of the control near the terrestrial TV input is to adjust optimal level of terrestrial TV signal. Maximal level must 

not exceed the upper limit (see specifications), at the same time it must not be too low to avoid interference from SAT TV lines. 

The subscriber's access to terrestrial TV line is permanent. Subscriber access to SAT TV lines is controlled by either analogue 

control signals or DiSEqC signals, which comes from the receiver through RF cable.

up position

down position

Terr.TV 
attenuator switch

Terr.TV input

VHi input

HHi input 

18 V  output

HLo input 

  18 V output

VLo input

DC voltage 
indicator

Four positions SAT B IF attenuator switch.

Separate attenuator switch for each SAT IF input

Functional 

grounding clamp

Four positions SAT A IF attenuator switch.
Separate attenuator switch for each SAT IF input

SAT B

SAT A

SAT B

SAT A

SAT B

SAT A

SAT B

SAT A

A

B

A

B

A

B

A

B

Active Terr. DC 12V

Terr

.

Active

Passive

Off

On

OK

SAT A

Att. dB

Att. dB

DC 18V H,Lo/H,Hi

0 4 8 12

0 4 8 12

0 4 8 12

0 4 8 12

Att. dB

Att. dB

Att. dB

0 4 8 12

0 4 8 12

0 4 8 12

0 4 8 12

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

SAT B

0 4 8 12

0 1 2 3 

V,Hi

V,Lo

H,Hi

H,Lo

+

Switch for supply 12V 
through Terr.TV input

230V      50/60Hz  25W

Multiswitch MR916L

Multiswitch MR916L

Frequency range  SAT TV

950-2400 MHz
    47-790 MHz
 

Maximum output level SAT

93 dBµV

Terr. TV
                           

Maximum output level TERR (Rec.1-

8

)

DC output current  18V+14V+12V

88 dBµV

    

1 A

 

max

14V+12V

    0.5 A

 max

 

12V

    0.1 A

 max

 

Rec.1/3

Rec.9/11

Rec.5/7

Rec.13/15

Rec.2/4

Rec.6/8

Rec.10/12

Rec.14/16

A

B

A

B

A

B

A

B

Outputs

Outputs

passive

active

Mounting 

supports

Mounting 

supports

B

Mounting 

supports

Mounting 

supports

Содержание MR908L

Страница 1: ...ding clamp have common potential Otherwise floating voltage can damage product Shields of cables must be connected to main potential equalization bus MONTAGE VIEW Mount the multiswitch in vertical position with RF input connectors on the left side The multiswitch must be fixed with steel screws Ø 4 5 mm The screws are not included in a package Check position of switch Active Terr DC 12V to prevent...

Страница 2: ...V Output level for Terr TV outputs 1 8 85 dBµV IMD3 60 dB outputs 9 12 83 dBµV outputs 13 16 82 dBµV SAT inputs decoupling 30 dB Outputs decoupling 30 dB Supply voltage through RF inputs H Lo and H Hi 18 V V Lo and V Hi 14 V Terr TV 12 V DC supply current 18V 14V 12V 1 A through RF inputs 14V 12V 0 5 A 12V 0 1 A Current consumption from receiver 60 mA Control signals 14 18 V 0 22 kHz tone burst or...

Страница 3: ...ży w poziomie z wejściowymi złączmi F po lewej stronie Montuj w miejscach w których prawdopodobnie nie będzie dzieci Ekrany kabli muszą być podłączone do głównej szyny wyrównania potencjałów Należy zachować co najmniej 10 cm wolnej przestrzeni na górze z boku oraz z dołu multiswitcha Urządzenie wyprodukowane zostało zgodnie z obowiązującymi w Unii Europejskiej przepisami w tym zgodnie z dyrektywą ...

Страница 4: ...lanie na wejściach RF H Lo H Hi 18 V V Lo V Hi 14 V TV naziemna 12 V Natężenie prądu na 18V 14V 12V 1 wejściach RF A 14V 12V 0 5 12V 0 1 Pobór prądu z odbiornika mA 60 Sygnały sterujące 14 18 V 0 22 kHz tone burst lub DiSEqC 2 0 Pobór mocy 230V AC 50 60 Hz 4 W Zakres temperatur pracy ºC 20 50 Masa kg 1 44 PARAMETRY TECHNICZNE Tor SAT TV sterowany jest z odbiorników abonenckich Sygnały sterujące 14...

Отзывы: