![Teridian 71M6534H Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/teridian/71m6534h/71m6534h_user-manual_1088919029.webp)
71M6534H Demo Board User’s Manual
Page: 29 of 86
© 2005-2007 TERIDIAN Semiconductor Corporation
V2-0
1.9.5 AUTOMATIC CALIBRATION (AUTO-CAL)
The Demo Code is able to perform a single-point fast automatic calibration, as described in section 2.2.3. This
calibration is performed for channels A, B, and C only, not for the NEUTRAL channel. The steps required for the
calibration are:
1. Enter operating values for voltage and current in I/O RAM. The voltage is entered at MPU address
0x10 (e.g. with the command
)10=+2400
for 240V), the current is entered at 0x11 (e.g. with the
command
)11=+300
for 30A) and the duration measured in accumulation intervals is entered at 0x0F.
2. The operating voltage and current defined in step 1 must be applied at a zero degree phase angle to
the meter (Demo Board).
3. The CLB (Begin Calibration) command must be entered via the serial interface. The operating voltage
and current must be maintained accurately while the calibration is being performed.
4. The calibration procedure will automatically reset CE addresses used to store the calibration factors to
their default values prior to starting the calibration. Automatic calibration also reads the chip
temperature and enters it at the proper CE location temperature compensation.
5. CE addresses 0x10 to 0x15 and 0x18 to 0x1A will now show the new values determined by the auto-
calibration procedure. These values can be stored in EEPROM by issuing the CLS command.
Tip: Current transformers of a given type usually have very similar phase angle for identical operating
conditions. If the phase angle is accurately determined for one current transformer, the corresponding
phase adjustment coefficient
PHADJ_X
can be entered for all calibrated units.
1.9.6 LOADING THE 6534_DEMO.HEX FILE INTO THE DEMO BOARD
Hardware Interface for Programming:
The 71M6534/6534H IC provides an interface for loading code into the
internal flash memory. This interface consists of the following signals:
E_RXTX (data), E_TCLK (clock), E_RST (reset), ICE_E (ICE enable)
These signals, along with V3P3D and GND are available on the emulator header J14. Production meters may
be equipped with much simpler programming connectors, e.g. a 6x1 header.
Programming of the flash memory requires a specific in-circuit emulator, the ADM51 by Signum Systems
(http//www.signumsystems.com) or the Flash Programmer (TFP-2) provided by TERIDIAN Semiconductor.
Chips may also be programmed before they are soldered to the board. The TGP1 gang programmer suitable for
high-volume production is available from TERIDIAN. It must be equipped with LQFP-120 sockets.
In-Circuit Emulator:
If firmware exists in the 71M6534/6534H flash memory; it has to be erased before loading
a new file into memory. Figure 1-7 and Figure 1-8 show the emulator software active. In order to erase the flash
memory, the RESET button of the emulator software has to be clicked followed by the ERASE button ().
Once the flash memory is erased, the new file can be loaded using the commands File followed by Load. The
dialog box shown in Figure 1-8 will then appear making it possible to select the file to be loaded by clicking the
Browse button. Once the file is selected, pressing the OK button will load the file into the flash memory of the
71M6534/6534H IC.
At this point, the emulator probe (cable) can be removed. Once the 71M6534/6534H IC is reset using the reset
button on the Demo Board, the new code starts executing.
Flash Programmer Module (TFP-2):
Follow the instructions given in the User Manual for the TFP-2.
Содержание 71M6534H
Страница 2: ...71M6534H Demo Board User s Manual Page 2 of 86 2005 2007 TERIDIAN Semiconductor Corporation V2 0...
Страница 8: ...71M6534H Demo Board User s Manual Page 8 of 86 2005 2007 TERIDIAN Semiconductor Corporation V2 0...
Страница 40: ...71M6534H Demo Board User s Manual Page 40 of 86 2005 2007 TERIDIAN Semiconductor Corporation V2 0...