December 2019
Service and Repair Manual
Control System Fault Codes
Part No. 1285305GT
S
®
-60 J
87
ID Component ID Name
Cause
Effect
Solution
74 Engine
Temperature
15 Sensor
value too
low
Engine
temperature sensor
is shorted to
ground
Engine will not
operate
* With a voltmeter, check that
C26TSR ( WH/RD, TCON J6P8) is
not shorted to ground and voltage is
between 0.1-11.5V
* Replace sensor if necessary
23 Too high The engine coolant
temperature is
measured as too
high, potentially
damaging the
engine.
Engine will not restart
until machine power
is cycled. Engine
may stop itself,
depending on the
engine option.
* Stop engine as soon as possible.
* Verify the engine coolant level.
* Verify the engine coolant/water
pump.
* Power on the machine and start the
engine. At the ground controls
display, view the engine temperature
gauge for proper operation.
* If engine uses an analog
temperature sensor, verify it is
sending an analog voltage on
C26TSR (WH/RD, TCON J6-10).
76 Platform
Load Sensor
13 Not
detected
TCON has not
detected the
DISCON on the
communications
bus.
Boom Up, Extend
and Turntable Rotate
functions will not
operate.
* Verify sensor power P26PWR (BK,
PCON J13-9) is at 12 V while the
system is running.
* Verify 12 V across pins on C27-2 (+)
and C27-3 (-) on the harness
connector.
* Measure resistance across C27 pins
4 and 5 on the harness connector. If
resistance is not between 55 and
65 ohms, check CAN wire harnesses.
* Replace sensor if necessary.
14 Cross
check
failed
TCON has not
detected the
DISCON on the
communications
bus.
Boom Up, Extend
and Turntable Rotate
functions will not
operate.
* Check that the load sensor is
mounted correctly and all fasteners
are tightened to spec.
* Calibrate load sensor.
* Replace sensor if issue persists.
15 Value to
low
Platform load
sensor out of
calibration
Machine limited to
recovery functions
* Make sure the platform is not
touching the ground or an overhead
obstruction. Cycle power and check
that fault is no longer reported.
* Perform the platform overload
calibration procedure.
* Replace sensor if necessary.
17 Not
calibrated
Platform load
sensor out of
calibration
* Calibrate load sensor.
* Replace sensor if issue persists.
21 Fault
Platform load
sensor out of
calibration
* Check that the load sensor is
mounted correctly and all fasteners
are tightened to spec.
* Calibrate load sensor.
* Replace sensor if issue persists.
Содержание S-60 J
Страница 65: ...December 2019 Service and Repair Manual Part No 1285305GT S 60 J 53 This page intentionally left blank ...
Страница 67: ...December 2019 Service and Repair Manual Manifolds Part No 1285305GT S 60 J 55 ...
Страница 69: ...December 2019 Service and Repair Manual Manifolds Part No 1285305GT S 60 J 57 ...
Страница 75: ...December 2019 Service and Repair Manual Part No 1285305GT S 60 J 63 This page intentionally left blank ...
Страница 77: ...December 2019 Service and Repair Manual Manifolds Part No 1285305GT S 60 J 65 ...
Страница 114: ...Service and Repair Manual December 2019 102 S 60 J Part No 1285305GT This page intentionally left blank ...
Страница 115: ...December 2019 Service and Repair Manual 103 Electrical Schematic Generator Options ...
Страница 116: ...Service and Repair Manual December 2019 104 S 60 J Part No 1285305GT Electrical Schematic Generator Options ...
Страница 117: ...December 2019 Service and Repair Manual Part No 1285305GT S 60 J 105 Electrical Schematic Positive Air Shutdown ...
Страница 118: ...Service and Repair Manual December 2019 106 Electrical Schematic Positive Air Shutdown ...
Страница 119: ...December 2019 Service and Repair Manual 107 Electrical Schematic Turntable Controller ...
Страница 120: ...Service and Repair Manual December 2019 108 S 60 J Part No 1285305GT Electrical Schematic Turntable Controller ...
Страница 121: ...December 2019 Service and Repair Manual Part No 1285305GT S 60 J 109 Electrical Schematic Platform Controller ...
Страница 122: ...Service and Repair Manual December 2019 110 Electrical Schematic Platform Controller ...
Страница 123: ...December 2019 Service and Repair Manual 111 Electrical Schematic Kubota D1803 ...
Страница 124: ...Service and Repair Manual December 2019 112 S 60 J Part No 1285305GT Electrical Schematic Kubota D1803 ...
Страница 125: ...December 2019 Service and Repair Manual Part No 1285305GT S 60 J 113 Electrical Schematic Kubota D1105 ...
Страница 126: ...Service and Repair Manual December 2019 114 Electrical Schematic Kubota D1105 ...
Страница 127: ...December 2019 Service and Repair Manual 115 Electrical Schematic Deutz D2011 ...
Страница 128: ...Service and Repair Manual December 2019 116 S 60 J Part No 1285305GT Electrical Schematic Deutz D2011 ...
Страница 129: ...December 2019 Service and Repair Manual Part No 1285305GT S 60 J 117 Hydraulic Schematic ...
Страница 131: ......