![Terex Genie Lift Guard S-40 Скачать руководство пользователя страница 164](http://html.mh-extra.com/html/terex/genie-lift-guard-s-40/genie-lift-guard-s-40_maintenance-manual_1088666164.webp)
Maintenance Manual
March 2022
Programmed Maintenance Procedures
148
S
®
Booms • Z
®
Booms
Part No. 1268489GT
P0-5
Cummins Engine Maintenance – Under 1000 Hours
Additional engine maintenance is required. Refer to the
Programmed Maintenance Inspection Report
for
the specific intervals that apply.
Required maintenance procedures and additional engine information are available in the manufacturer's
manuals. Refer to Specifications,
Engine Operator and Maintenance Manuals
.
Cummins B3.3T
Hour Intervals
Procedure
∅ =
Not required
Daily
250
500
Oil, fuel and coolant systems - check for leaks
∅
∅
Fuel-water separator - drain
∅
∅
Oil level - check
∅
∅
Coolant level - check
∅
∅
Drive belt - inspect
∅
∅
Cooling fan - inspect
∅
∅
Engine oil - replace
∅
∅
Oil filter - replace
∅
∅
Valve lash clearance - adjust (initial, one-time interval with oil change)
∅
∅
Air intake system - inspect
∅
∅
Air cleaner restriction - check
∅
∅
Fuel filter - replace
∅
∅
Fuel supply lines - vent
∅
∅
Injection pump - vent
∅
∅
Cooling system - check
∅
∅