![Terex Genie Lift Guard S-40 Скачать руководство пользователя страница 163](http://html.mh-extra.com/html/terex/genie-lift-guard-s-40/genie-lift-guard-s-40_maintenance-manual_1088666163.webp)
March 2022
Maintenance Manual
Programmed Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
147
P0-4
Continental Engine Maintenance – Under 1000 Hours
Additional engine maintenance is required. Refer to the
Programmed Maintenance Inspection Report
for
the specific intervals that apply.
Required maintenance procedures and additional engine information are available in the manufacturer's
manuals. Refer to Specifications,
Engine Operator and Maintenance Manuals
.
Continental TME27
Hour Intervals
Procedure
∅ =
Not required
Daily
50
100
250
500
Visual inspection of engine
∅
∅
∅
∅
Oil level - check
∅
∅
∅
∅
Air cleaner - check
∅
∅
∅
∅
PCV system - check
∅
∅
∅
∅
Coolant level - check
∅
∅
∅
∅
Oil, fuel and coolant systems - check for leaks
∅
∅
∅
∅
Air filter discharge valve - clean
∅
∅
∅
∅
Fan belt tension - check
∅
∅
∅
∅
Battery - check
∅
∅
∅
∅
Engine oil - replace
∅
∅
∅
∅
Oil filter - replace
∅
∅
∅
∅
Harness connections - check
∅
∅
∅
∅
Cooling system - check
∅
∅
∅
∅
Air filter - replace
∅
∅
∅
∅
PCV valve - check
∅
∅
∅
∅
Valve tappet clearance - adjust
∅
∅
∅
∅
Fuel system - check
∅
∅
∅
∅
Fuel pump - check
∅
∅
∅
∅
Fuel filter - replace
∅
∅
∅
∅