Service and Repair Manual
March 2021
Type "FXXX" Faults
174
GS
™
-30 • 32 • 46 • 47
Part No. 1272217GT
Type "FXXX" Faults
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
F001:
GS-3232
F001:SWITCHFAULT
UP LIMIT1:BAT+
Short circuit of the up limit #1 switch at
system startup.
• Short circuit of the up limit switch circuit.
• Up limit #1 switch short circuit.
• GCON ECM.
Platform up function
inhibited.
F003:
GS30,
GS32,
GS46 &
GS47
F003:SWITCHFAULT
DOWN LIMIT1:BAT+
Short circuit of the down limit #1 switch at
system startup.
• Short circuit of the down limit switch circuit.
• Down limit #1 switch short circuit.
• GCON ECM.
All functions inhibited
except platform down.
F005:
GS30,
GS32,
GS46 &
GS47
F005:SWITCHFAULT
POTHOLE:BAT+
Short circuit of the pothole limit #1 switch at
system startup.
• Short circuit of the pothole switch circuit.
• Pothole limit #1 switch short circuit.
• GCON ECM.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
F007:
GS30,
GS32,
GS46 &
GS47
F007:SWITCHFAULT
CHASSISTILT:BAT+
Short circuit of the chassis digital tilt switch
at system startup.
• Short circuit of the chassis digital tilt switch
circuit.
• Chassis digital tilt switch short circuit.
• GCON ECM.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
F008:
GS30,
GS32,
GS46 &
GS47
F008:SENSORFAULT
OVLD XDUCER:BAT+
Short circuit of the Platform Overload
Transducer circuit to battery positive.
• Short circuit in the transducer circuit.
• Faulty pressure transducer.
• GCON ECM.
All functions inhibited.
F009:
GS30,
GS32,
GS46 &
GS47
F009:SENSORFAULT
OVLD XDUCER:BAT-
Short circuit of the Platform Overload
Transducer circuit to battery negative.
• Short circuit in the transducer circuit.
• Faulty pressure transducer.
• GCON ECM.
All functions inhibited.
F010:
GS30,
GS32,
GS46 &
GS47
F010:SENSORFAULT
PLAT HEIGHT:BAT+
Short circuit of the Platform Height Sensor
circuit to battery positive.
• Short circuit in the platform height circuit.
• Faulty platform height sensor.
• GCON ECM.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
F011:
GS30,
GS32,
GS46 &
GS47
F011:SENSORFAULT
PLAT HEIGHT:BAT-
Short circuit of the Platform Height Sensor
circuit to battery negative.
• Short circuit in the platform height circuit.
• Faulty platform height sensor.
• GCON ECM.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
Содержание Genie GS-1530
Страница 205: ...March 2021 Service and Repair Manual Wiring Diagram Ground and Platform Controls Part No 1272217GT GS 30 32 46 47 189 ...
Страница 243: ...March 2021 Service and Repair Manual 227 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 246: ...Service and Repair Manual March 2021 230 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 297: ...March 2021 Service and Repair Manual 281 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 300: ...Service and Repair Manual March 2021 284 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 337: ...March 2021 Service and Repair Manual 321 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 339: ...March 2021 Service and Repair Manual 323 Electrical Schematic Foot Switch option All Models ...
Страница 341: ......