Troubleshooting 10
Operations Manual
Bison 120
20-07-2018
Page 10-9
Revision 2.0
(8) Electrical
Fault
Cause
Correct Measure
Control panel lights up
but engine does not
start
Faulty ignition switch
Replace ignition switch
Low engine oil level (warning
light should be on)
Top up oil level
Low engine coolant level
(warning light should be on)
Top up coolant level
Emergency stop buttons
depressed
Check all emergency stop
buttons
Faulty starter motor
Replace starter motor
Control panel does
not light up
Low battery voltage
Top up electrolyte level
Charge up battery
Isolator on
Turn off isolator
Faulty ignition switch terminals
Correct connections/replace
Damaged battery
Replace battery
Battery goes flat while
engine is running
Low battery voltage
Top up electrolyte level
Charge up battery
Faulty Alternator
Replace alternator
Loose fan belt
Adjust tension
Faulty starter motor
Replace starter motor
Track radio remote
control does not work
Remote control is out of range
Move remote control to within
100 m of the machine
Batteries are dead
Charge or replace batteries
Remote control not programmed
to receiver box
Program receiver box
Components do not
start
Faulty switch
Check for power
Replace switch
PVG solenoid
Check for power
Replace solenoid
Wiring connection (loose)
Carry out visual inspection
Содержание Evoquip Bison 120
Страница 2: ...EvoQuip 200 Coalisland Road Dungannon Co Tyrone BT71 4DR Telephone 44 0 28 8774 0701...
Страница 23: ...Operations Manual Bison 120 20 07 2018 Page 2 7 Revision 2 0 Safety 2 Figure 2 1 Location of Safety Signs...
Страница 36: ...2 Safety Operations Manual Bison 120 20 07 2018 Page 2 20 Revision 2 0 Intentionally Left Blank...
Страница 42: ...3 Technical Data Operations Manual Bison 120 20 07 2018 Page 3 6 Revision 2 0 Intentionally Left Blank...
Страница 102: ...7 Standard Operating Procedures Operations Manual Bison 120 20 07 2018 Page 7 20 Revision 2 0 Intentioanlly Left Blank...
Страница 116: ...9 Maintenance Operations Manual Bison 120 20 07 2018 Page 9 8 Revision 2 0 Figure 9 2 Grease Points Cont...
Страница 196: ...10 Troubleshooting Operations Manual Bison 120 20 07 2018 Page 10 22 Revision 2 0 Intentionally Left Blank...
Страница 197: ...Storage 11 Operations Manual Bison 120 20 07 2018 Page 11 1 Revision 2 0 Table of Content 11 Storage 11 2...
Страница 204: ...Operations Manual Bison 120 20 07 2018 Page 12 6 Revision 2 0 12 Glossary of Terms Intentionally Left Blank...
Страница 206: ...Appendix Operations Manual Bison 120 20 07 2018 Page 13 2 Revision 2 0 Intentionally Left Blank...
Страница 208: ...Appendix A Operations Manual Bison 120 20 07 2018 Page A 2 Revision 2 0...
Страница 214: ...Appendix B Operations Manual Bison 120 20 07 2018 Page B 6 Revision 2 0 Intentionally Left Blank...
Страница 216: ...Appendix C Operations Manual Bison 120 20 07 2018 Page C 2 Revision 2 0 Intentionally Left Blank...
Страница 218: ...Appendix C Operations Manual Bison 120 20 07 2018 Page C 4 Revision 2 0 b Front Panel CPU Connection Cont...
Страница 219: ...Appendix C Operations Manual Bison 120 20 07 2018 Page C 5 Revision 2 0 c Main Wiring...
Страница 220: ...Appendix C Operations Manual Bison 120 20 07 2018 Page C 6 Revision 2 0 d Relay Box...
Страница 223: ......