DPTR Rail Mount Differential Pressure Transmitter-Operation Manual                                        Edition: A/3

 

1

 

DPTR Rail Mount Differential Pressure Transmitter 

                     

                                               

 

 
 
 

 

 

Applications & Features 

 

Mount  on  standard  35mm  DIN  rail,  small  enough  for 
compact installation in equipments and instruments 

 

Apply high accuracy MEMS sensor and digital technologies, 
can  measure  differential  pressure  on  equipment  such  as 
isolators and clean benches for pharmaceutical production, 
biological  and  medicine  research,  microelectronics, 
hazardous chemicals operations, and general laboratories 

 

Multiple ranges, engineering units and outputs 

 

Good performance, accuracy 1.0% or 0.5%FS selectable 

 

Function  keys:  zero  reset,  unit  select,  response  time  set, 
etc 

Specifications 

Medium:

 non-combustible, non-corrosive air, insensitive to 

moisture, dust, condensation and oil 

Temp.: 

Working,-20~70°C; Medium, 0~60°C; Compensation, 0~50°C 

Storage: -30~70°C 

Working Pressure: 

overload 10xFS, burst 15xFS 

Performance:   

Accuracy %FS 

±1.0% 

±0.5% 

Thermal 
effect %FS/°C(Zero/FS) 

±0.05/0.08 

±0.03/0.04 

Stability %FS/Year 

±0.5 

±0.3 

Response Time: 

0.5/1/2/5s, can be set by keys

 

Process Connection: 

5mm ID tubing

 

Output: 

0~10V, 4~20mA (2 wires), RS485 selectable

   

 
 
 
Output Load: 

≤500Ω (current), ≥2kΩ (voltage)

 

Power: 

Current: 18.5~35VDC (R

L

=500Ω)8.5~35VDC (R

L

=0Ω)

 

Voltage: 16~28VAC/ 16~35VDC

 

Zero reset: 

outside key to operate easily 

Materials:

 Fire-proof ABS+PC

 

Protection: 

IP30 

Weight:

 110g

 

Approval: 

CE 

Models 

Model 

 

DPTR   

 

   

Rail Mount DP Transmitter   

Accuracy 

 

 

 

±1%FS 

±0.5%FS 

Range 

 

 

 

 

Range selection(See table) 

Output 

 

 

 

1  0~10V 
2  4~20mA(2 wires) 
8  RS485/Modbus 

Measuring ranges

   

Note: 

For  zero  center  models,  add  “Z”  at  the  end  of  the  model.  For  example, 

DPTR*1*Z, means the range is -30-0-30.Only 1~6 have this selection. 

Connection 

Different  models  have  different  electrical  terminals.  Please  wire  specific  model  according  to  the  wiring  diagram  on  the  front 
cover. 

 

 

 

 

 

Setting 

1. The zero-reset button is for resetting zero drift. Press and hold the button for 5 seconds to complete the operation. 
2. The RS485 terminating resistor (120Ω) is selected by the toggle switch. When “J8” is ON, the resistor (120Ω) is applied. 
3. Response Time select: switch the S2 to different positions for 0.5s,1s, 2s and 5s according to the diagram below. 

Note: since the time is not fully synchronized, the actual response time is 1~2 times set time.   

 

 

 

Code 

Pa 

Code 

Pa 

0

~

25 

0

~

1000 

0

~

60 

0

~

2500 

0

~

125 

0

~

5000 

0

~

250 

0

~

10000 

0

~

500 

 

 

RS485

9600,8,N,1

Slave Add.= 1

3     4

A

1     2

POWER   SUPPLY

B

24VDC/AC

V

3     4

POWER   SUPPLY

24VDC

A

3     4

POWER   SUPPLY

1     2

Current Output 4-20mA

Voltage Output 0-10V

RS485/Modbus RTU Output

24VDC/AC

ON

1

2

ON

1

2

ON

1

2

ON

1

2

0.5S

1S

2S

5S

S2

RS485 terminal
resistance
(inside product)

ON

1

J8

zero-reset

Отзывы: