1-2

 

 Warning

 

 

 

Be sure to keep the terminal box cover attached 
during the operation of the pump. 

Otherwise, it may lead to an electric shock. 

Do not forcibly bend, pull, or pinch the power cable 
or any lead wires of the product.   

Otherwise, it may lead to an electric shock or fire. 

 

After detaching the companion flange from the pump, 
screw a pipe into it. 

Otherwise, it may lead to damage or leakage. 

Before starting the maintenance or inspection work, 
be sure to stop the pump and turn off the main 
power of the panel board. 

Otherwise, it may lead to an electric shock, injury, damage, or 
leakage. 

 

 

Check the wiring sections and wires for any 
looseness. 

A loose connection may cause a fire or electric shock. 

Before rotating the pump shaft by hand to check its 
smooth rotation, be sure to turn off the main power.

Otherwise, it may lead to an injury or damage. 

 

Before starting the unit or carrying out 
maintenance/inspection work, ensure that all the 
relevant workers are informed of the operation and 
that there are no workers in the dangerous zone. 

Otherwise, it may lead to an unforeseen accident. 

[VKN-e] Do not perform zero-discharge operation.
[VKP-e] Do not perform long hours of 
zero-discharge operation continuously. 

Otherwise, the temperature and pressure may increase inside 
the pump, thus damaging the pump or causing steam to blow 
off. 

 

 

After turning on the power, do not touch any parts of 
the pump other than those required for operation. 

Otherwise, it may lead to an electric shock or injury. 

For overhaul, replacement of parts, or repairs, ask 
the vendor or the service center specified by Teral.

If unskilled personnel carry out work that requires special 
knowledge, it may lead to an accident or failure. 

 

 

Do not put your fingers or foreign objects into any 
openings or rotating part of the motor during 
operation. 

Otherwise, it may lead to an injury or damage. 

In the event of a power failure, be sure to turn off 
the power switch. 

Otherwise, the pump may suddenly start up on restoration of 
the power, thus leading to an injury. 

 

 

 

 

 Caution 

 

 

Do not use the unit outside the range of the product 
specifications. 

Otherwise, it may lead to an electric shock, fire, leakage, failure, 
or other problems. 

Do not use the unit at an incorrect power voltage. 

An incorrect voltage may damage the motor. 

 

Do not use a single pump unit as the only means of 
directly operating key facilities or sustaining life. 

In the event of a failure, the liquid supply may stop. Ensure to 
make a backup unit available for operation. 

Before unpacking the delivered container, check 
that the container is placed in the correct 
orientation (not upside down). Carefully unpack the 
container, while paying special attention to nails. 

Otherwise, it may lead to an injury or damage. 

 

Ensure that the floor at the unit’s installation place is 
waterproofed and fitted with drainage. 

Otherwise, it may lead to serious damage in the event of 
leakage. 

Do not install two or more different cables or control 
wires in one pipe or duct. 

Otherwise, it may lead to malfunction of the product or other 
equipment. 

 

Do not step on the pump or motor. 

Otherwise, it may lead to an injury, damage, or other problems.

Do not expose the motor to liquid. 

Otherwise, it may lead to an electric shock, electric leak, 
failure, or other problems. 

 

Operate the controls carefully. 

Otherwise, it may lead to an injury or damage. 

During test operation, never run the pump dry (i.e. 
never run the pump when the liquid level is below 
the Minimum liquid level). 

Otherwise, it may lead to damage or a fire.

 

 

Before operation, thoroughly clean (flush) the inside 
of the piping to remove foreign matter. 

Otherwise, the piping system may be contaminated with foreign 
matter, thus leading to an accident or a pump failure. 

During normal operation, do not run the pump dry 
for more than 30 seconds. 

Otherwise, it may lead to damage or a fire. 

 

Do not put a cloth or other covering on the motor. 
Otherwise, it may lead to overheating or ignition. 

Do not touch the motor body while the pump is 
running or immediately after the pump has stopped.
Otherwise, you may get burns from the hot surface.

 

In the event of an alarm or abnormal condition that 
cannot be resolved, immediately stop the operation, 
turn off the power, and then contact Teral or its 
service provider. 

Otherwise, it may lead to an accident. 

Do not run the pump with tools or other objects 
placed on the unit. 

Otherwise, it may lead to an injury or damage. 

Содержание VKN-e Series

Страница 1: ...Model VKN e VKP e Coolant Pump Coolant Pump Instruction Manual Original Instructions...

Страница 2: ...warranty period 3 Failures and breakage caused by disasters or force majeure such as fire acts of God or earthquakes 4 Failures and breakage resulting from repairs or modifications made without the co...

Страница 3: ...tion labels 1 3 2 Configuration and overview of the pump 2 1 2 1 Part names and functions 2 1 2 2 Naming rule of the model codes 2 1 2 3 Standard specifications 2 2 2 4 Information indicated on the na...

Страница 4: ...product in any explosive atmosphere Otherwise it may lead to an injury or fire Warning Properly move the unit according to hoisting instructions Otherwise the unit may fall thus leading to an injury o...

Страница 5: ...Otherwise it may lead to an electric shock fire leakage failure or other problems Do not use the unit at an incorrect power voltage An incorrect voltage may damage the motor Do not use a single pump...

Страница 6: ...the pump until it does Otherwise the main shaft may be subjected to an excessive load which makes the service life of the pump shorter When you hoist the product pay attention to its center of gravity...

Страница 7: ...t specifications in such a case Caution Do not use this product under any conditions other than those provided in the specifications Otherwise it may lead to an electric shock fire leakage or failure...

Страница 8: ...d the limit specified in the following table the service life of the motor may become shorter and the motor may burn out Be sure to use a liquid with a dynamic viscosity below the limit specified in t...

Страница 9: ...plate to verify that the delivered product is exactly what you ordered Be sure to confirm the model motor output frequency and voltage If there is anything different from what you ordered contact the...

Страница 10: ...le current value indicated on the pump nameplate is the recommended preset current value of the protective device Model VKP e Model Specifications VKP115A e Output W 750 Rated voltage V 200 200 220 Fr...

Страница 11: ...Rotation direction Mounting hole Suction Discharge View from P P Rotation direction plate Drain hole Ground terminal Discharge Suction Rotation direction Mounting hole View from P P Bottom of the tank...

Страница 12: ...ece Phosphor bronze 9 O ring NBR 10 Terminal box SPCC 11 Motor main shaft S45C 12 Motor VKP115A e No Part name Material 1 Spiral box FC150 2 Pump leg FC150 200 3 Impeller CAC407 4 Key S45C 5 Pressing...

Страница 13: ...tly incline depending on its center of gravity Warning Before transporting or moving the product confirm the weight of each unit by referring to the catalog dimensional outline drawing and other docum...

Страница 14: ...urface with sand paper or the like and then coat it which improves the adhesion properties of the coating film Be sure to check the overcoatability of the paint 7 Do not install the product in a place...

Страница 15: ...nk as possible with its suction height as low and its suction pipe length as short as possible In addition do not install the pump at a position lower than the liquid level at a slanted posture or wit...

Страница 16: ...ipes to rest on the pump Otherwise the main shaft may be displaced from the center thus leading to equipment damage vibration or noise 3 Do not forcibly screw a pipe into the pump Otherwise it may bre...

Страница 17: ...amount of liquid released from the relief pipe is too much the liquid temperature easily rises in the tank oil tank 11 On completion of the piping work be sure to clean the tank oil tank Pay attentio...

Страница 18: ...d preset current refer to the rated current shown in 2 5 Specification table page 2 4 9 Take adequate dust proofing and drip proofing measures using a connector gland or other means to prevent any cut...

Страница 19: ...selecting the inverter If the pump and motor produce resonance during normal operation do not run them in the range of the rotation speed Caution Do not run the pump at a frequency exceeding 60 Hz Ot...

Страница 20: ...the shaft sealing device Note that if the length H in the right figure from the feed port of priming liquid to the pump discharge port is shorter than the length L of the suction pipe below the liqui...

Страница 21: ...ure to attach the cover of the terminal box of the motor Otherwise it may lead to an electric shock Warning Do not operate the pump if any abnormal condition is observed or if there is anything wrong...

Страница 22: ...ease the liquid temperature in the pump Therefore allow a small amount of liquid to flow at least 3L min or if you no longer use the liquid stop the pump Too hot liquid may reduce the service life of...

Страница 23: ...Total amplitude m V Vibration velocity mm s n Equipment rotation speed min 1 13 Do not allow a large amount of cutting powder from entering the pump Otherwise it may clog the pump strainer damage the...

Страница 24: ...if the temperature difference between the motor surface and the atmosphere does not exceed 40 C Because prelubricated shielded bearings are used there is hardly any need for maintenance of the bearin...

Страница 25: ...mp shaft Carefully handle the seal to ensure the proper operation of the pump 2 The mechanical seals are consumables They wear at a different rate depending on the properties of circulating liquid the...

Страница 26: ...emble and inspect No abnormal condition When worn out Main shaft and its surrounding area Smooth rotation Rotate by hand Rotation is smooth and uniform 4 1 Bearing motor 2 Heat Touch Not unusually hot...

Страница 27: ...ct the power company User The stator winding is broken shorted or grounded Contact the vendor because disassembly and inspection are required Vendor The stator and rotor are in contact due to wear of...

Страница 28: ...matter thus leading to imbalanced load Disassemble and check Contact the vendor because disassembly and inspection are required Vendor Cavitation has occurred Contact the manufacturer and vendor User...

Страница 29: ...efer to Section 0 Troubleshooting page 6 1 For disassembly inspection or repair ask the vendor from which you purchased the product or ask Teral Refer to the end of this document Never repair the pump...

Страница 30: ...e wiring and piping For the layout in the terminal box refer to Section 3 5 Precautions for wiring work page 3 5 4 Remove the pump mounting bolts and then hoist the pump Refer to Section 3 3 Precautio...

Страница 31: ......

Страница 32: ...Moriwake Miyuyki cho Fukuyama city Hiroshima 720 0003 Japan Tel 084 955 1111 Fax 084 955 5777 Overseas Div TERAL Koraku Bldg 2 3 27 Koraku Bunkyo ku Tokyo 112 0004 Japan Tel 03 3819 6890 Fax 03 3818...