3.3  Precautions for installation 

[VKN-e/VKP-e] 

Warning

 

Before rotating the pump shaft by hand to check it, be sure to turn off the 
main power. An unexpected start of the pump may cause an accident. 

(1)  Install the product in a well-ventilated place with minimum exposure to dust and moisture. (Refer 

to the Installation location in “2.3. Standard specifications    [page 2-2]”). In particular, avoid 
installing the product in a place where the pumping liquid may be splashed on the motor section. 

Warning

 

Do not install the product in a hot or humid place. 
Otherwise, it may lead to heating, ignition or electric leak. 

(2)  Install the product so that the motor can take air in. 

(3)  Securely install the product on a flat place without 

any wobbles.   

(4)  The mounting surface must be strong enough to 

prevent the amplification of vibrations while the pump 
is running. 
(Restrict the total amplitudes in X, Y, and Z directions 
(see the right figure) to 33

μ

m at 50 Hz and to 29

μ

at 60 Hz during the operation of the pump.) 

(5)  Select a convenient place to conduct maintenance 

and inspection. Secure space for maintenance. 

(6)  The product is coated. If you need to overcoat it in a 

different color for a compelling reason, lightly 
roughen the product surface with sand paper or the 
like and then coat it, which improves the adhesion 
properties of the coating film. (Be sure to check the 
overcoatability of the paint.) 

(7)  Do not install the product in a place where a secondary hazard could occur in the event of any 

liquid leak. 

(8)  If the system could be exposed to the freezing temperature in winter, be sure to apply antifreeze 

measures such as heat insulation and heater installation to the pump, valves, piping, etc. 

(9)  Securely install the pump. 

Recommended size of pump mounting bolt:  M10 

The pump is provided with four mounting bolt-holes, but they are intended to extend the range of 

use. You can install the pump using only two diagonally-located mounting holes without any 
problems. 

Note

 

Securely fix the pump in place with the bolts. Otherwise, it may lead to 
abnormal vibration or other problems. 

(10) Do not hoist the equipment with the pump attached. Otherwise, it may damage the hoisting 

equipment/devices and the pump may fall. 

(11) When you hoist or move the pump, be sure to handle the pump carefully so that the pump section 

would not be subjected to an impact or imbalanced load. The container may greatly tilt depending 
on its center of gravity. 

Y: Measurement direction 

X: Measurement 
direction 

Z: Measurement point 

Y: Measurement 
direction

Z: Measurement 
point

X: Measurement 
direction

X, Y: Measurement point
(VKN-e/VKP-e)

Z: Measurement direction
(VKN-e/VKP-e)

VKN-e 

VKP-e 

Содержание VKN-e Series

Страница 1: ...Model VKN e VKP e Coolant Pump Coolant Pump Instruction Manual Original Instructions...

Страница 2: ...warranty period 3 Failures and breakage caused by disasters or force majeure such as fire acts of God or earthquakes 4 Failures and breakage resulting from repairs or modifications made without the co...

Страница 3: ...tion labels 1 3 2 Configuration and overview of the pump 2 1 2 1 Part names and functions 2 1 2 2 Naming rule of the model codes 2 1 2 3 Standard specifications 2 2 2 4 Information indicated on the na...

Страница 4: ...product in any explosive atmosphere Otherwise it may lead to an injury or fire Warning Properly move the unit according to hoisting instructions Otherwise the unit may fall thus leading to an injury o...

Страница 5: ...Otherwise it may lead to an electric shock fire leakage failure or other problems Do not use the unit at an incorrect power voltage An incorrect voltage may damage the motor Do not use a single pump...

Страница 6: ...the pump until it does Otherwise the main shaft may be subjected to an excessive load which makes the service life of the pump shorter When you hoist the product pay attention to its center of gravity...

Страница 7: ...t specifications in such a case Caution Do not use this product under any conditions other than those provided in the specifications Otherwise it may lead to an electric shock fire leakage or failure...

Страница 8: ...d the limit specified in the following table the service life of the motor may become shorter and the motor may burn out Be sure to use a liquid with a dynamic viscosity below the limit specified in t...

Страница 9: ...plate to verify that the delivered product is exactly what you ordered Be sure to confirm the model motor output frequency and voltage If there is anything different from what you ordered contact the...

Страница 10: ...le current value indicated on the pump nameplate is the recommended preset current value of the protective device Model VKP e Model Specifications VKP115A e Output W 750 Rated voltage V 200 200 220 Fr...

Страница 11: ...Rotation direction Mounting hole Suction Discharge View from P P Rotation direction plate Drain hole Ground terminal Discharge Suction Rotation direction Mounting hole View from P P Bottom of the tank...

Страница 12: ...ece Phosphor bronze 9 O ring NBR 10 Terminal box SPCC 11 Motor main shaft S45C 12 Motor VKP115A e No Part name Material 1 Spiral box FC150 2 Pump leg FC150 200 3 Impeller CAC407 4 Key S45C 5 Pressing...

Страница 13: ...tly incline depending on its center of gravity Warning Before transporting or moving the product confirm the weight of each unit by referring to the catalog dimensional outline drawing and other docum...

Страница 14: ...urface with sand paper or the like and then coat it which improves the adhesion properties of the coating film Be sure to check the overcoatability of the paint 7 Do not install the product in a place...

Страница 15: ...nk as possible with its suction height as low and its suction pipe length as short as possible In addition do not install the pump at a position lower than the liquid level at a slanted posture or wit...

Страница 16: ...ipes to rest on the pump Otherwise the main shaft may be displaced from the center thus leading to equipment damage vibration or noise 3 Do not forcibly screw a pipe into the pump Otherwise it may bre...

Страница 17: ...amount of liquid released from the relief pipe is too much the liquid temperature easily rises in the tank oil tank 11 On completion of the piping work be sure to clean the tank oil tank Pay attentio...

Страница 18: ...d preset current refer to the rated current shown in 2 5 Specification table page 2 4 9 Take adequate dust proofing and drip proofing measures using a connector gland or other means to prevent any cut...

Страница 19: ...selecting the inverter If the pump and motor produce resonance during normal operation do not run them in the range of the rotation speed Caution Do not run the pump at a frequency exceeding 60 Hz Ot...

Страница 20: ...the shaft sealing device Note that if the length H in the right figure from the feed port of priming liquid to the pump discharge port is shorter than the length L of the suction pipe below the liqui...

Страница 21: ...ure to attach the cover of the terminal box of the motor Otherwise it may lead to an electric shock Warning Do not operate the pump if any abnormal condition is observed or if there is anything wrong...

Страница 22: ...ease the liquid temperature in the pump Therefore allow a small amount of liquid to flow at least 3L min or if you no longer use the liquid stop the pump Too hot liquid may reduce the service life of...

Страница 23: ...Total amplitude m V Vibration velocity mm s n Equipment rotation speed min 1 13 Do not allow a large amount of cutting powder from entering the pump Otherwise it may clog the pump strainer damage the...

Страница 24: ...if the temperature difference between the motor surface and the atmosphere does not exceed 40 C Because prelubricated shielded bearings are used there is hardly any need for maintenance of the bearin...

Страница 25: ...mp shaft Carefully handle the seal to ensure the proper operation of the pump 2 The mechanical seals are consumables They wear at a different rate depending on the properties of circulating liquid the...

Страница 26: ...emble and inspect No abnormal condition When worn out Main shaft and its surrounding area Smooth rotation Rotate by hand Rotation is smooth and uniform 4 1 Bearing motor 2 Heat Touch Not unusually hot...

Страница 27: ...ct the power company User The stator winding is broken shorted or grounded Contact the vendor because disassembly and inspection are required Vendor The stator and rotor are in contact due to wear of...

Страница 28: ...matter thus leading to imbalanced load Disassemble and check Contact the vendor because disassembly and inspection are required Vendor Cavitation has occurred Contact the manufacturer and vendor User...

Страница 29: ...efer to Section 0 Troubleshooting page 6 1 For disassembly inspection or repair ask the vendor from which you purchased the product or ask Teral Refer to the end of this document Never repair the pump...

Страница 30: ...e wiring and piping For the layout in the terminal box refer to Section 3 5 Precautions for wiring work page 3 5 4 Remove the pump mounting bolts and then hoist the pump Refer to Section 3 3 Precautio...