ENC-400-HDMI
™ H.264 Encoder
User Guide V 2.1
70
4.3.3
TCP configuration: DEC-
200™ is the Server
Please make the following steps, to create a TCP connection at which the DEC-
300™ is the server:
Please open the ENC-
300™ webpage, go to the
ENCODER > DESTINATION
webpage and
select in the
‘Transport Protocol’
drop-down field the variable
‘TCP/CLIENT’
.
Remain at the
ENCODER > DESTINATION
webpage of the ENC-
300™ and enter in the
‘IP
address’
field the IP-address of the DEC-
300™ (e. g. 172.16.20.200). Note: TCP supports only
unicast.
At the
ENCODER > DESTINATION
webpage of the ENC-
300™, please enter in
‘Port’
field a
port number, which is not used in the network and which is not blocked (e. g. 1234).
Remain at the
ENCODER > DESTINATION
webpage of the ENC-
300™ and enter a number in
the
‘Send Buffer Size’
field (e.g. 250000). The ’Send Buffer Size’ specifies how much TCP data
are maximal stored at the sender side (at the encoder side). The higher the value, the more
network problems can be absorbed, but the higher is the delay at the decoder in error case.
After an error case, the delay decreases again. The delay increases only, if an error occurs in
the network. That means: If no network problems occur, the delay does not increase, even
though a high value is set in the ’Send Buffer Size’ field.
Remain at the
ENCODER > DESTINATION
webpage of the ENC-
300™ and enter in
‘Stop
Interval’
field the time interval in sec. for reconnecting in error case. This field is active when
‘TCP/CLIENT’ or ‘UDP’ is used as ‘Transport Protocol’ in the ENC-300™.
Please open the
DEC-
200™
webpage, go to the
DECODER > SOURCE
webpage and select
in the
‘Transport Protocol’
drop-down field the variable
‘TCP/SERVER’
.
Remain at the
DECODER > SOURCE
webpage of the DEC-
200™ and enter in the
‘Port
number’
field the same port number, which you have entered in the ENC-
300™ (e.g. 1234).
Now the ENC-
300™ and the DEC-200™ are configured for a TCP-connection.