Technical parameters 

 

Supply voltage, VDC 

12 ± 2 

Maximum current ( with all relays ON), mA 

370 

Weight, g 

205 

Dimensions, mm 

115 x 90 x 40 

Operating temperature, °C 

 0 to +40 

Maximum humidity in 0 to 31°C range, %RH 

 80 

Maximum humidity at 40°C (linear slope between 31-40°C), %RH 

 50 

Minimum high level input voltage for digital inputs, VDC 

+2.5 

Maximum low level input voltage for digital inputs, VDC 

+0.8 

Maximum input voltage for digital inputs, VDC 

+5.5 

Maximum switchable current for relay contacts, А  

3  

Maximum switchable voltage for relay contacts, VAC/VDC 

30/24 

 
4.

 

Connectors 

The location of the connectors and LED’s are shown below: 
 

Connector 1  

Pin 1/2/3 

- NO/COM/NC of Relay5

 

Pin 4/5/6 

- NO/COM/NC of Relay6 

Pin 7/8/9 

- NO/COM/NC of Relay7 

Pin 10/11/12  - NO/COM/NC of Relay8 

Connector 2 

Pin 1/2/3 

- NC/COM/NO of Relay4

 

Pin 4/5/6 

- NC/COM/NO of Relay3 

Pin 7/8/9 

- NC/COM/NO of Relay2 

Pin 10/11/12  - NC/COM/NO of Relay1 

Connector 3 

Pin 1   

- Digital input (

DI

)*

 

Pin 2   

- Ground 

Pin 3   

- +12VDC 

Connector 4 

Power, Ø2mm, central positive

 

Connector 5 

- Ethernet – RJ45 

 

 

* O

perating mode is selected by jumper DI on PCB - closed for “dry contact” and open for 

“logic level”. By default jumper is closed. 
 

5.

 

LED indicators 

The following indicators show the status of the controller: 

 

Relay 1 to 8 status

 (green) - turns ON when the corresponding relay is activated; 

 

Sts

 (red) – flashes when the main program of controller is executed; 

 

Log

 (yellow) – turns ON when someone is logged to the controller via WEB interface; 

 

Link

 (green) – located on the Ethernet connector, turns ON when the device is 

connected to the LAN; 

 

Act

 (yellow) – located on the Ethernet connector, flashes when activity on the LAN is 

detected. 
 

Содержание TCW181B-CM

Страница 1: ...ut is suitable for solving specific problems in various fields such as remote control process automation home automation and others 2 Features 10 Mb Ethernet connectivity Password protected web based configuration and control 1 digital input with logic level and dry contact modes 8 relays with NO and NC contacts SNMP v 1 support Sending SNMP Traps messages under certain conditions Sending E mail m...

Страница 2: ...NO COM NC of Relay7 Pin 10 11 12 NO COM NC of Relay8 Connector 2 Pin 1 2 3 NC COM NO of Relay4 Pin 4 5 6 NC COM NO of Relay3 Pin 7 8 9 NC COM NO of Relay2 Pin 10 11 12 NC COM NO of Relay1 Connector 3 Pin 1 Digital input DI Pin 2 Ground Pin 3 12VDC Connector 4 Power Ø2mm central positive Connector 5 Ethernet RJ45 Operating mode is selected by jumper DI on PCB closed for dry contact and open for log...

Страница 3: ...ler if recommended free spaces to adjacent devices are not ensured Joint part with external component shall have space for attachment removal of the cable after installation Teracom does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications To ensure that the device works correctly follow the steps below ensure that the...

Страница 4: ...for mechanical details Maintain spacing from adjacent equipment Allow 50 mm of space on all sides as shown on fig 2 in Appendix A This provides ventilation and electrical isolation 11 Configuration Please follow the steps below for proper installation 1 Mount the controller in a dry and ventilated place 2 Connect the Ethernet port to a 10 100MB Ethernet network For direct connection to a PC use a ...

Страница 5: ... to login the following message appears Someone s logged in The active session will be terminated automatically if the current user stays inactive for 2 minutes 11 2 Monitoring page After successful authorization the Monitoring page appears The Monitoring page provides information about the state of the relays and digital input ...

Страница 6: ...P address is static DNS these fields is mandatory if domain names are used instead of IP addresses By default DNS has the same Ip address as Default gateway Time Server and Time Zone these fields are not mandatory they are used when e mail must be sent Host Name up to 16 symbols it appears as a Subject in sent e mails MAC device MAC address The good practice is to change the default IP address of ...

Страница 7: ...ings for SNMP section are SNMP Configuration enable disable SNMP Read Write community performs client authentication Read Only community performs client authentication SNMP Traps enable disable SNMP trap messages IP address IP address of the receiving host Community string performs client authentication Trap Interval time interval in seconds for SNMP trap messages Max Traps number maximum number o...

Страница 8: ...put can mange e mail sending Following parameters must be set Mail to e mail address of recipient Subject e mail subject Message e mail body Important It is necessary to set SMTP server settings on Network Setup page to successfully send e mail messages In the example above if an event occurs closing contact the controller will send e mail message to info teracom cc with subject input alarm and bo...

Страница 9: ...Network Management Protocol This could be done using every SNMPv 1 compatible program Parameters that can be changed are grouped according to their functions in the tables below To obtain a valid OID number it is necessary to replace the x symbol with the 1 3 6 1 4 1 38783 To save the changes configurationSaved OID x 6 0 should be set to 1 13 1 Product OID Name Access Description Syntax x 1 1 0 na...

Страница 10: ...7 pulse state INTEGER 0 255 x 3 17 0 Pulse8 read write Relay 8 pulse state INTEGER 0 255 x 3 18 0 allOn read write Set all relays On INTEGER 0 255 x 3 19 0 allOff read write Set all relays Off INTEGER 0 255 x 3 20 0 allPulse read write Pulse all relays INTEGER 0 255 13 4 Network OID Name Access Description Syntax x 4 1 0 deviceIPAddress read write Device IP address IpAddress x 4 2 0 subnetMask rea...

Страница 11: ...SIZE 0 22 x 6 0 configurationSaved read write Configuration save status SAVED UNSAVED INTEGER SAVED 1 UNSAVED 0 x 7 0 restartDevice read write Restart Device INTEGER RESTART 1 CANCEL 0 14 XML and HTTP API commands XML is often preferred choice when it comes to M2M communication and system integration The monitored values are transmitted in status xml file that can be easily processed by software a...

Страница 12: ... Name Admin admin Password Admin admin IP Address 192 168 1 2 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 SNMPConfiguration disabled readCommunity public writeCommunity private 16 Firmware update TCW181B CM supports remote firmware update To update the device follow the steps below Download the TCW1XX_Update_Tool program from www teracom cc Download the latest firmware version file cod f...

Страница 13: ...TCW181B CM_R1 Page 13 Appendix A Fig 1 Fig 2 ...

Отзывы: