background image

  

 

TCW122B-WD_R2            ( Firmware version 2.xx ) 

Page 3 

 

 

Link

 (green) – located on the Ethernet connector, indicates that the device is connected to 

the network; 

 

Act

 (yellow) – located on the Ethernet connector, flashes when activity is detected on the 

network. 

6.

 

Powering 

TCW122B-WD

 is designed to be supplied by adapter SYS1421-0612-W2E or similar, intended for 

use in the conditions of overvoltage category II, and priorly assessed for compliance with safety 
requirements. The power supply equipment shall be resistant to short circuit and overload in secondary 
circuit. 

When in use do not position the equipment so that it is difficult to operate the disconnecting 

device. 

 

7.

 

Environment information  

This equipment is intended for use in a Pollution Degree 2 environment, at altitudes up to 2000 

meters. 

When the controller is a part of a system, the other elements of the system shall comply with the 

EMC requirements and shall be intended for use in the same ambient conditions. 

 

8.

 

Safety 

This device must not be used for medical, life saving purposes or for any purpose where its failure 

could cause serious injury or the loss of life. 

To reduce the risk of fire, only flexible stranded wire, with cross section 0.5mm² or larger for 

wiring of digital and analog inputs and relay output of the device should be used.  

To avoid electric shock and fire hazard, do not expose this product to liquids, rain, or moisture. 

Objects filled with liquids, such as vases, should not be placed on this device. 

There is a risk of overheating (damage) of controller, if recommended free spaces to adjacent 

devices are not ensured. Joint part with external component shall have space for attachment/removal of 
the cable after installation. 

Teracom does not guarantee successful operation of the product if the product was used under 

conditions deviating from the product specifications. 

To ensure that the device works correctly follow the steps below: 

 

ensure that the device is installed correctly, refer this user manual; 

 

log in to the devices via browser program; 

 

make proper set up; 

 

set up the digital inputs to work in “dry contact” mode; 

 

short the “Din1” and “GND”; 

 

install sensor TSH1XX or TST1XX on 1-Wire bus; 

 

go to “Monitoring page” of WEB interface – proper parameters value should be displayed in 
the same time flashing “STS” led should indicate the proper operation. 

If the equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired. 

In no event will Teracom Ltd. be responsible or liable for indirect or consequential damages 

resulting from the use or application of this equipment. 

 
 
 
 

Содержание TCW122B-WD

Страница 1: ...programs TCW122B WD is suitable for IP watchdog monitoring environmental monitoring of server rooms as well for building automation remote control alarm systems etc 2 Features 10 Mb Ethernet connecti...

Страница 2: ...locations are shown below Connector 1 Power central positive Connector 2 Pin1 Digital input 1 Din1 Connector 2 Pin2 Digital input 2 Din2 Connector 2 Pin3 Ground Connector 2 Pin4 Analog input 1 Ain1 C...

Страница 3: ...or larger for wiring of digital and analog inputs and relay output of the device should be used To avoid electric shock and fire hazard do not expose this product to liquids rain or moisture Objects f...

Страница 4: ...ent equipment Allow 50 mm of space on all sides as shown on fig 2 in Appendix A this provides ventilation and electrical isolation 11 Configuration Please follow the steps below for proper installatio...

Страница 5: ...itoring page After successful authorization the Monitoring page appears The Monitoring page provides information about the state of the relays and digital inputs values of analog voltages applied on a...

Страница 6: ...is considered when the parameter goes higher than MIN HISTERESYS or lower than MAX HISTERESYS For watchdog function following parameters can be set Mode outgoing echo request or incoming echo replay m...

Страница 7: ...ateway these fields are active if IP address is static DNS these fields is mandatory if domain names are used instead of IP addresses By default DNS has the same IP address as Default gateway Host Nam...

Страница 8: ...ite Read community performs client authentication SNMP Traps enable disable SNMP trap messages IP address IP address of the receiving host Community string performs client authentication Trap Interval...

Страница 9: ...diagrams 12 1 Watchdog TCW122B WD device is set to send periodic ping to AP Local network and remote server Internet If there is no answer in Ping time out for restart the corresponding relay is activ...

Страница 10: ...ead only Device name String x 1 2 0 version read only Firmware version String x 1 3 0 date read only Release date String 14 2 Setup network OID Name Access Description Syntax x 2 1 1 0 deviceIPAddress...

Страница 11: ...ntax x 2 6 1 1 0 temperature2Min read write Temperature2 range min value INTEGER 400 1250 x 2 6 1 2 0 temperature2Max read write Temperature2 range max value INTEGER 400 1250 x 2 6 1 3 0 temperature2H...

Страница 12: ...ss IpAddress x 2 11 5 0 wdg2NumberOfRestarts read write Watchdog 2 Max Number of restarts INTEGER 1 253 14 15 Monitor and control OID Name Access Description Syntax x 3 1 0 digitalInput1State read onl...

Страница 13: ...55 255 0 Default Gateway 192 168 1 1 SNMP Configuration disabled Read Community public Write Community private 16 Firmware update TCW122B WD supports remote firmware update To update the device follow...

Страница 14: ...TCW122B WD_R2 Firmware version 2 xx Page 14 Appendix A Fig 1 Fig 2...

Страница 15: ...TCW122B WD_R2 Firmware version 2 xx Page 15...

Страница 16: ...TCW122B WD_R2 Firmware version 2 xx Page 16...

Отзывы: