4. Technical parameters
Supply voltage, VDC
8 - 32
Maximum current consumption (with both relays ON), mA
Weight, g
130
Dimensions, mm
107 x 72 x 32
Operating temperature, °C
0 to +40
Maximum humidity in 0 to 31°C range, %RH
80
Maximum humidity at 40°C (linear slope between 31-40°C), %RH
50
Quad band connectivity, MHz
850/900/1800/1900
GPRS Multi-slot Class
12, 1~12 configurable
GPRS Mobile Station
Class B
Compliant to GSM Phase 2/2+
Class 4
(2W@850/ 900MHz)
Class 1
(1W@1800/1900MHz)
Minimum high level input voltage for digital inputs, VDC
+2.5
Maximum low level input voltage for digital inputs, VDC
+0.8
Maximum input voltage for digital inputs, VDC
+5.5
Supply voltage for 1-wire bus (
VDD
), VDC
5.0 ± 0.2
Maximum output current for 1-wire bus (
VDD
), A
0.2
Analog inputs range, VDC
0 to +60
Maximum switchable current for relay contacts, А
3
Maximum switchable voltage for relay contacts, VAC/VDC
30/24
5. LED indicators
The following indicators show the status of the controller:
REL1-REL2
(green) – these LEDs are illuminated whenever the corresponding relay is
activated (the NO contact is closed and the NC contact is open);
SIG
(red) – this LED is used to indicate the GSM network signal level;
STA
(yellow) – indicates the working state of
TCG120
controller and system messages.
The controller states and system messages are shown in
Appendix A
.