MODE 5 LIMIT VALUE
This parameter defines the size of the detection zone for operating mode 5 only. The
detection area is created using object di/- the limit value. Default distance is 10cm
for each distance limit.
Slave ID
: 1 to 247
Address location
: 16
Value
: 50 to 1000 (in millimeters, default 100)
NO/NC ON TIME (applicable to mode 2, 4 and 5)
This parameter defines the amount of time the NO/NC switching output will remain
triggered. Default value is 250ms.
Slave ID
: 1 to 247
Address location
: 18
Value
: 50 to 1000 (in milliseconds, default 250)
Note:
Not applicable for operating modes 1 and 3. In these modes the NO/NC is triggered as long
as there is a detection within the selected trigger zone.
FLY ZONE SELECT
Selects the NO/NC trigger zone for special case 2. A value of 0 sets the fly zone to the closer
zone, while a value of 1 sets it to the far zone
Slave ID
: 1 to 247
Address location
: 20
Value
: 0 or 1 (default 0)
NPN/PNP SELECTED
This parameter defines whether the switching output is sourcing (PNP) or sinking power
(NPN). An example of NPN/PNP connection is available in
.
The default setting
value is 1 (NPN).
Slave ID
: 1 to 247
Address location
: 24
Value
: 1 or 2 (value 1 for NPN and 2 for PNP select, default 1)
Note: Requires sensor restart.