4.4.
Operating mode 2
Description
Mode 2 is used for applications such as counting moving objects/people, and monitoring
object height. A single background threshold is used to set a trigger zone. The sensor is
activated as soon as an object leaves the programmed trigger zone in the light beam.
Setup
Figure 11. Mode 2 setup phases
Step 1 - Set background threshold
●
Make sure that an object is fully covering the sensors Field of View at the preferred
background distance, then hold the PROG button for 1 second.
●
The LED indicators, Th1 and Th2 (both GREEN), will now go from ON to OFF status to
confirm entering programming mode.
●
Once the programming mode is completed, the sensor enters the “time delay for
operation mode” for 2 seconds by default (see
to configure this
parameter).
●
After that, LED indicators, Th1 and Th2, will turn ON and stay fixed (GREEN) to verify
a properly stored background threshold.
Step 2 - Sensor ready
●
The background is now taught in and the sensor is in operation mode.