8.3 Install 15A, 25A and 5A safety devices, control panel indicator will light.
8.4 Set type of a pomp established on your heater (point 6.1.3). Set heater operating
time (point 6.1.4). If operating time isn't established, the heater will work 40 min.
8.5 To perform the pre-heater operation test press the middle button. The pre-heater
shall start combustion; the information will be on the indicator. Further on the pre-heater
operates automatically. Upon termination of established operating time, the heater will be
switched off automatically. To stop the work of the pre-heater is possible at any time
pressing the middle knob on the control panel.
8.6 While performing the pre-heater operation test it is necessary to check if the
heater fan switches on. Normally the fan is activated when the cooling liquid reaches
40°C.
8.7 If the pre-heater demonstrates faulty operation during its switching on or in the
process of operation, malfunction code will be on the indicator.
8.8 The productivity of the fuel pump is not big, that’s why when the fuel line is
empty, and it is filled slowly. The pre-heater performs 2 tries of ignition and if there’s no
fuel yet stops the activity with malfunction code 13- «No more tries to start the pre-heater
are left». There’s need to switch on the pre-heater until the fuel fills the fuel pipe line.
Movement of fuel into a transparent tube of pipeline can be observed visually. Besides,
filling of working volume of the pump with fuel is supervised aurally: at existence of the
fuel into the fuel pump the sound accompanying movement of a plunzher is considerably
muffled, without the fuel into fuel pump ringing clicks are audible.
8.9 Start the pre-heater with the vehicle engine on and verify its operation.
Attention!
1.
Note that cooling fluid temperature readings displayed on the vehicle instrument
panel and control panel may vary, as temperature is measured in different parts of the
fluid system of the vehicle.
2
After check of operability of a heater it is necessary to check once again tightness
of connections of pipelines with a pump, the heater and the engine, if necessary to tighten
clamps.
9
Recommendations.
9.1
If the pre-heater won’t start after switching on, check the fuel in the tank, the
battery charged, connectors and fuse 25A are in order.
9.2
If control panel won’t work (indicator is not lighting) check fuse 5A
9.3
If vehicle heater fan won’t start automatically when the temperature of cooling
liquid over 40°C, check fuse 15A and relay.
9.4
If the pre-heater won’t switch on and switch off or after purging of the
combustion chamber the fan motor will rotate, it is a sign of system failure. For
elimination of this failure it is necessary take off fuses 5A, 25A on 10 second and then
install them again in sequence first 25A, then 5A.
9.5
All the rest malfunctions are identified automatically and are shown on the
control panel indicator.
9.6
See the list of malfunctions and troubleshooting in the table 6.1 of the present
manual.
33
Содержание Binar-5B-Compact
Страница 19: ...Рис 6 25 Схема управления пультом ...
Страница 46: ...Modem GSM TERMINAL car alarm system harness Harness Controlpanel 1 1 i 11 i CD lAtr intake with silencer ...
Страница 56: ...Figure 6 25 The scheme of navigation o n the control panel ...
Страница 74: ...ENG Binar 5B 5D Compact Заметки Notes 36 ...