background image

 

13-280137  Rev. C 

June 2013 

Teo Technologies, Inc.

 

11609 49

th

 Place West 

Mukilteo, WA 98275-4255 

(800) 524-0024  (425) 349-1000 

Fax (425) 349-1010 

www.teotech.com 

 

 

U

U

C

C

 

 

P

P

r

r

o

o

 

 

S

S

e

e

r

r

v

v

e

e

r

r

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

I

I

n

n

s

s

t

t

r

r

u

u

c

c

t

t

i

i

o

o

n

n

s

s

 

 

Содержание UC Pro

Страница 1: ...Technologies Inc 11609 49 th Place West Mukilteo WA 98275 4255 800 524 0024 425 349 1000 Fax 425 349 1010 www teotech com U UC C P Pr ro o S Se er rv ve er r I In ns st ta al ll la at ti io on n I In ns st tr ru uc ct ti io on ns s ...

Страница 2: ...Teo UC Pro Server Installation Instructions Page 2 13 280137 Rev C 2013 Teo Technologies Inc All rights reserved ...

Страница 3: ... 17 Ethernet Network Connection 18 Telephony Connections 19 Configuration and Administration 27 Joining the Local Domain 27 Configuring System Options 27 User Configuration Options 29 Specifications 31 Service and Warranty 33 Service 33 Teo Product Warranty 33 Safety and Regulatory Requirements 35 Cautions 35 FCC Part 15 35 National Electrical Code 35 C C Co o on n nt t te e en n nt t ts s s ...

Страница 4: ...Teo UC Pro Server Installation Instructions Page 4 13 280137 Rev C ...

Страница 5: ...ll routing Fax Server E911 LDAP Active Directory integration Mass provisioning of users Mass provisioning of devices Centralized administration of all system functions U Us si in ng g t th hi is s M Ma an nu ua al l This manual covers the hardware installation and initial configuration of the UC Pro Server Connectors switches and indicators on the front and back panels are described in this chapte...

Страница 6: ... the UC Pro Server front panel Remove the front bezel to access the reset button power button hard drive bays USB and serial ports and a DVD drive F Fr ro on nt t B Be ez ze el l R Re em mo ov va al l Press the red lever left to unlatch the front bezel and then pull the bezel forward to remove The bezel may be locked using the included key to prevent removal ...

Страница 7: ... fan failure Continuously on not flashing indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm NIC 2 flashing indicates network activity on Ethernet interface 2 WAN NIC 1 flashing indicates network activity on Ethernet interface 1 LAN HDD flashing indicates hard drive and or DVD ROM drive activity Power i...

Страница 8: ...80137 Rev C B Ba ac ck k P Pa an ne el l The back panel has connectors for Power supplies Ethernet ports PRI ports Analog ports Other computer connectors typically used for troubleshooting only o Keyboard o Mouse o VGA video o RS232 serial port o USB ports ...

Страница 9: ...the following steps to install the UC Pro Server 1 Mount the UC Pro Server in the rack 2 Connect the UC Pro Server to the LAN 3 Connect the Telco ISDN PRI port s to the UC Pro Server 4 Connect AC power 5 Connect optional analog lines and analog devices to the UC Pro Server 6 Configure the UC Pro Server to join the network domain I I In n ns s st t ta a al l ll l la a at t ti i io o on n n ...

Страница 10: ...nstall telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Do not attach or staple the AC power cord to any building surface CAUTION To reduce the risk of fire use only No 26 AWG...

Страница 11: ...outer rails 2 Rack short rear outer rails 1 Front bezel key 1 Installation Instructions this manual L Lo oc ca at ti io on n R Re eq qu ui ir re em me en nt ts s The UC Pro Server installation requires a clean secure room on the customer premises The room must have adequate ventilation and room for front and rear panel access The UC Pro Server must be installed per articles 115 15 110 17 and 110 1...

Страница 12: ...ent in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up Always keep the rack s front door and all panels and components on the servers closed when not servicing to maintain proper cooling Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Equipment should b...

Страница 13: ...of f t th he e R Ra ac ck k R Ra ai il ls s Two rack rail assemblies are included in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself S Se ep pa ar ra at ti in ng g t th he e I In nn ne er r a an nd d O Ou ut te er r R Ra ai il ls s 1 Locate the ...

Страница 14: ... inner rails are pre attached The inner rail extension is attached to the inner rail to mount the chassis in the rack 1 Place the inner rack extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure that the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis w...

Страница 15: ...ace The outer rails extend between 30 inches and 33 inches 1 Secure the back end of the outer rail to the rack using the screws provided 2 Press the button where the two outer rails are joined to retract the smaller outer rail 3 Hang the hooks of the rails onto the rack holes and if desired use screws to 3 secure the front of the outer rail onto the rack 4 Repeat steps 1 3 for the remaining outer ...

Страница 16: ...d the outer rails as illustrated below 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be used to secure the front of the server to the rack ...

Страница 17: ...ds If multiple circuits are available at the equipment site connect each power cord to a separate power circuit to ensure that the server will continue to operate if one circuit fails Your system is configured in the computer BIOS to automatically start when power is connected This setting ensures that the UC Pro Server will restart in the event of a temporary loss of power To manually turn the UC...

Страница 18: ...v C E Et th he er rn ne et t N Ne et tw wo or rk k C Co on nn ne ec ct ti io on n Use a Category 5 or better network cable Connect the ETH0 port on the UC Pro Server to your LAN The local SIP telephone devices are on this LAN DO NOT connect anything to the ETH1 port ...

Страница 19: ...sition connector surrounded by a metal shield connects to an ISDN Primary Rate Interface PRI trunk A An na al lo og g P Po or rt ts s To determine analog port configuration apply power to the server before connecting any analog trunks or station devices this will illuminate the installed ports The color and size of the connector indicates the port configuration Analog Station Device FXS Port Four ...

Страница 20: ...wo o o or r F Fo ou ur r P PR RI I P Po or rt ts s F Fo ou ur r F FX XS S F FX XO O P Po or rt ts s This card can be configured with 4 FXS 4 FXO or 2 FXS 2 FXO ports O On ne e F FX XS S F Fo ou ur r F FX XO O P Po or rt ts s Each FXO connector on this card has two ports Line splitter cords are supplied with this card option O On ne e P PR RI I O On ne e F FX XS S F Fo ou ur r F FX XO O P Po or rt ...

Страница 21: ... each card are numbered 1 4 with port 1 on the bottom Note The connector arrangement and number of connectors per card may differ depending on the server configuration Connect each PRI port to an ISDN PRI trunk using standard Ethernet cables Note Some installations may require a PRI swap cable or swap adapter to reverse the transmit and receive pairs I IS SD DN N P PR RI I T Tr ru un nk k P Po or ...

Страница 22: ...ver ports are used when connecting analog trunks or station devices Multiple cards with analog ports may be installed some cards may also include PRI ports When facing the back of the server card 1 is on the left as shown below Ports on each card are numbered 1 4 with port 1 on the bottom Note The connector arrangement and number of connectors per card may differ depending on the server configurat...

Страница 23: ...ns below Note The connector orientation may be reversed rotated 180 on some cards 4 4 P Po os si it ti io on n C Co on nn ne ec ct to or r Use the supplied yellow crossover cord Connect the 4 position plug to the server and connect the 6 position plug to the analog trunk jack 6 6 P Po os si it ti io on n C Co on nn ne ec ct to or r Use the supplied line splitter cord as shown to connect to two ind...

Страница 24: ... C Co on nn ne ec ct to or r P Pi in no ou ut ts s Server Pin Number 4 Position Plug Analog Trunk Pin Number 6 Position Plug Signal 1 5 2 4 Tip 3 3 Ring 4 2 Server Pin Number 6 Position Plug Analog Trunk 1 Pin Number 6 Position Plug Analog Trunk 2 Pin Number 6 Position Plug Signal 1 2 4 Tip 2 3 4 Tip 1 4 3 Ring 1 5 3 Ring 2 6 ...

Страница 25: ... some cards 4 4 P Po os si it ti io on n C Co on nn ne ec ct to or r Use the supplied yellow crossover cord Connect the 4 position plug to the server and connect the 6 position plug to the analog device 6 6 P Po os si it ti io on n C Co on nn ne ec ct to or r Use a standard telephone line cord to connect to the analog device A An na al lo og g D De ev vi ic ce e F FX XS S P Po or rt t C Co on nn n...

Страница 26: ...Teo UC Pro Server Installation Instructions Page 26 13 280137 Rev C ...

Страница 27: ... options are set via a web based remote administration session 2 Open a web browser on any computer that has access to the LAN A widescreen display of at least 1680 x 1050 resolution is recommended Adobe Flash Player is required 3 Browse to the address of the UC Pro Server 4 When the login screen appears log in to the UC Pro Server using the administration username and password that was supplied b...

Страница 28: ...e menus at the top of the screen to access the configuration options Online help is available for most configuration options Click the icon to view help in a new browser tab or window When finished with the administration session click LOGOUT at the upper right of the screen ...

Страница 29: ...or must set up an account name and password for each user The user needs to browse to the login page UC Pro Server address A display resolution of 1024 x 768 is sufficient for the User Portal interface Adobe Flash Player is required After logging in the user can access their call history and configuration options Online help is available for most configuration options by clicking the icon ...

Страница 30: ...Teo UC Pro Server Installation Instructions Page 30 13 280137 Rev C ...

Страница 31: ...t 2 required P Ph hy ys si ic ca al l Dimensions 3 5 H x 19 W x 27 D including mounting brackets Weight 40 lbs E En nv vi ir ro on nm me en nt ta al l Operating Temperature 32 to 104 F 0 to 40 C Storage Temperature 4 to 185 F 20 to 85 C Humidity 0 to 95 non condensing S S Sp p pe e ec c ci i if f fi i ic c ca a at t ti i io o on n ns s s ...

Страница 32: ...Teo UC Pro Server Installation Instructions Page 32 13 280137 Rev C ...

Страница 33: ...not been misused damaged or improperly installed Repair or replacement under this warranty will be performed at Teo s factory Authorization must be obtained from Teo prior to returning a product for repair Freight must be prepaid for all units returned to Teo Units repaired under warranty will be shipped UPS Ground or equivalent freight prepaid by Teo Products that are older than the warranty peri...

Страница 34: ...Teo UC Pro Server Installation Instructions Page 34 13 280137 Rev C ...

Страница 35: ...ference when the equipment is operated in a commercial environment This unit generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct t...

Страница 36: ...Teo UC Pro Server Installation Instructions Page 36 13 280137 Rev C ...

Отзывы: