background image

 

________________________________________________________________________________________________________________________________

 

TensioMed®

 

TensioDay

 

Plus™

 

1.

 

Introduction

 

 

Thank

 

you

 

for

 

choosing

 

TensioMed®

 

TensioDay

 

Plus™.

 

The

 

TensioMed®

 

TensioDay

 

Plus™,

 

ambulatory

 

blood

 

pressure

 

monitor

 

is

 

a

 

professional

 

device,

 

for

 

clinical

 

and

 

ambulatory

 

requirements,

 

validated

 

according

 

to

 

the

 

British

 

Hypertension

 

Society

 

and

 

the

 

Association

 

for

 

the

 

Advancement

 

of

 

Medical

 

Instrumentation

 

standards.

 

The

 

device

 

uses

 

oscillometric

 

method

 

for

 

blood

 

pressure

 

determination.

 

It

 

can

 

also

 

be

 

used

 

for

 

conventional

 

home

 

measurements,

 

executed

 

by

 

the

 

patients,

 

offering

 

a

 

high

 

level

 

measuring

 

quality

 

and

 

additional

 

features.

 

TensioMed®

 

TensioDay

 

Plus™

 

device

 

is

 

controlled

 

by

 

the

 

TensioMed®

 

TensioWin™

 

software.

 

The

 

measurement

 

schedule

 

and

 

the

 

blood

 

pressure

 

readings

 

are

 

loaded

 

via

 

bluetooth

 

communication

 

from

 

and

 

to

 

the

 

physician's

 

PC,

 

respectively.

  

Automatic

 

measurements

 

can

 

be

 

set

 

for

 

up

 

to

 

48

 

hours,

 

with

 

frequencies

 

ranging

 

from

 

10

 

to

 

90

 

minutes.

 

Separate

 

measurement

 

frequencies

 

can

 

be

 

set

 

for

 

the

 

“active”

 

daytime,

 

“passive”

 

night

time,

 

and

 

for

 

a

 

third

 

“special”

 

period.

 

The

 

measured

 

data,

 

namely

 

the

 

systolic

 

and

 

diastolic

 

BP

 

value,

 

the

 

pulse

 

rate,

 

the

 

date

 

and

 

time

 

of

 

the

 

measurement

 

will

 

be

 

stored

 

in

 

the

 

EEPROM

 

of

 

the

 

device.

   

  

Apart

 

from

 

the

 

programmed

 

measurements,

 

the

 

patient

 

may

 

start

 

a

 

manual

 

measurement

 

(e.g.:

 

he

 

shows

 

symptoms

 

or

 

feels

 

sick).

 

This

 

can

 

be

 

done

 

by

 

a

 

simple

 

push

 

button

 

operation.

 

All

 

manually

 

initiated

 

measurements

 

are

 

stored

 

and

 

displayed

 

on

 

the

 

software

 

report.

 

The

 

TensioMed®

 

TensioDay

 

Plus™

 

can

 

be

 

used

 

without

 

the

 

software

 

program,

 

for

 

conventional,

 

manually

 

started

 

BP

 

home

 

monitoring.

 

The

 

high

 

accuracy

 

of

 

the

 

measurements

 

and

 

the

 

storage

 

of

 

the

 

measured

 

data

 

offer

 

greater

 

flexibility.

 

The

 

storage

 

capacity

 

of

 

the

 

device

 

is

 

1000

 

measurements.

 

 

Содержание tensioday plus

Страница 1: ...blood pressure monitor featuring central blood pressure measurement With wireless communication Bluetooth Please read the user s manual carefully before the first use TensioMed TensioDay Plus 5 02 v2...

Страница 2: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 2...

Страница 3: ...s device 8 2 1 Explanation of symbols 8 2 2 Accessories 10 2 3 Installing the Device 10 2 4 Operations Instructions 11 2 4 1 Functions of the button on the device 12 2 4 1 1 One short push of the butt...

Страница 4: ...lood pressure readings are loaded via bluetooth communication from and to the physician s PC respectively Automatic measurements can be set for up to 48 hours with frequencies ranging from 10 to 90 mi...

Страница 5: ...company and product names mentioned herein may be trademarks of their respective companies 1 1 Contents of the manual This manual helps you in setting up and starting to use the TensioMed TensioDay Pl...

Страница 6: ...1182 Hungary Phone 36 1 433 1700 433 1701 Fax 36 1 433 1709 Web www tensiomed com E mail info tensiomed com 1 4 General Information warnings and precautions We strongly suggest that you carefully stud...

Страница 7: ...unit with special care Children should not use the device on their own Do not remove the outer cover of the device The TensioMed TensioDay Plus 24 hour BPM device is sophisticated multipurpose softwar...

Страница 8: ...flation continues above this value or the pressurization lasts too long unplug the pneumatic connector of the cuff from the device and remove the cuff from the subject Do not use the device on an arm...

Страница 9: ...anual 12 Certification mark guaranteeing that the apparatus complies with the prescriptions and requirements of the European Union 13 Serial number 14 Operating ambient temperature range 15 Year of th...

Страница 10: ...ircumference range Cuff S 20 8 cm 41 5 10 cm 20 24 cm Cuff M 23 11 5 cm 57 14 cm 24 32 cm Cuff L 28 x 11 5 cm 64 x 14 cm 32 38 cm The manufacturer of the cuffs ERKA Kallmeyer Medizintechnik GmbH Co KG...

Страница 11: ...ay The batteries and charging appliances have their own Instructions for use we suggest you study them and follow manufacturers guidelines In case you do not have a Bluetooth communication adapter or...

Страница 12: ...Day Plus is ready for operation D 09 39 2 4 1 1 One short push of the button starts a manual measurement During the ambulatory measuring mode there might be a need for manual measurements for example...

Страница 13: ...s ready for measurement for manual and programmed mode OFF 2 4 1 2 Two short pushes on the button Pill allows the patient to keep his electronic diary concerning taking his antihypertensive medication...

Страница 14: ...nloads all the stored data to the physician s PC via Bluetooth communication The information loaded consists of the systolic and diastolic blood pressure values mmHg the pulse rate per minute the dist...

Страница 15: ...the patient s blood pressure within the measuring time 3 The measurement was interrupted due to the weakness of the battery 31 The cuff is not connected to the device 32 The cuff tube is broken or so...

Страница 16: ...ree ambulation to avoid skin irritation a thin shirt might be used below the cuff the tube of the cuff should be inserted into the air connector of the device see figure 1 Attention Please take care o...

Страница 17: ...asurement method Oscillometric Data Storage Max 1000 measurements Blood Pressure measurements range 30 280 mmHg Static accuracy 3 mmHg or 2 of the measured value Measuring accuracy Systolic 94 out of...

Страница 18: ...ice is intended for use in the electromagnetic environment specified below The customer or the user of the TensioMed TensioDay Plus TD3 device should assure that it is used in such an environment Immu...

Страница 19: ...the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the TensioMed TensioDay Plus TD...

Страница 20: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 20...

Страница 21: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 21...

Страница 22: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 22...

Страница 23: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 23...

Страница 24: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 24...

Отзывы: