PTM-01 / PTM-02

DIGITAL POTENTIOMETER

         Attention       

        High Voltage,

 Double / Reinforced            NOT

            CE Mark

    Risk of Danger,   

             Risk of         

          Insulation

         Litter

         Warning         

       Electric Shock

TECHNICAL SPECIFICATION

Dimensions

: 35x77mm

Panel Cut-out

: 29x71mm

Display

: 4 Digits 7 Segment

Analog Output

: 0-10V or 4-20mA (Should be specified while ordering)

0-10V Load Imped.

:  

>5K

4-20mA max. Voltage 

:  <10V

Resolution

: 2mV (0-10V), 4µA (4-20mA)

Accuracy

: ± % 1 ; (Over full scale)

User Control

: Via Up/Down Front Panel Keys or Up/Down Digital Inputs

Digital Inputs

: Dry contact input only

Supply Voltage

: 100..240VAC, 50-60Hz or 24VDC/AC.

Power Consumption

: < 6VA

Humidity

: 80% up to 30

o

C, then linearly decreases to 50% at 50

o

C (non-condensing)

Altitude

: < 2000 m

EMC

: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)

Safety

: EN 61010-1; Pollution degree 1, measurement category 

I

, (Only light industrial

  environment, double/reinforced isolated, non-conductive pollution environment)

Protection Class

: IP20; according to EN 60529

Operation Temp.

: 0 .. 50 

o

C

Storage Temperature

: -10

o

C .. 60

o

C (no icing)

Weight

: < 0.5 kg

Keys

: Micro switch

Torque for screwing

: Max. 0.5 N.m

ERROR MESSAGES:

E.FLS / Err:

 Hardware failure, do NOT use device 

E.CAL / Err:

 Hardware failure, do NOT use device

E.EPr / Err:

 Memory failure, do NOT use device

WARNINGS:

Analog output of this device may generate undesirable signal level (i.e. out of scale and/or range)
for a short while after power on.

Analog output of this device may generate undesirable signal level (i.e. out of scale and/or range) if
a hardware failure happens or if supply voltage is out of range.

Analog output of this device may generate undesirable signal level (i.e. out of scale and/or range) if
an error message is displayed on the LED display.

For such reasons, do not directly use the analog output of this device to control a task. In your
applications, always use separate and independent mechanical / electromechanical / electronic
devices/apparatus to support this device. For example, if you use the analog output of this device to
control the speed of a motor driver, use an external forward/backward switch and/or an emergency
switch to enable the motor driver while you monitore the correct operation of the motor driver. For
example, do not enable motor driver via the external forward/backward switch and/or the
emergency switch if you read an error message on the LED display of this device.