12
TENNANT V-WD-24P
EN
TROUBLESHOOTING
Problem
Cause
Solution
Machine does not run
ON/OFF switch is off
Machine not plugged to wall outlet
Faulty on/off switch
Faulty power cord
Faulty vacuum motor
Faulty pump
Turn switch to on
Plug power cord to wall outlet
Contact service center
Contact service center
Contact service center
Contact service center
Machine has little or no
suction
Hose is clogged
Holes in hose
Intake is clogged
Head is not securely latched
Worn gasket which is leaking air
Tank or bag are full
Drain hose cap is loose
Clear hose
Replace hose
Remove hose and clear
obstruction
Latch both hooks down securely
Inspect all gaskets, replace if
necessary
Empty tank or bag.
Tighten cap
TECHNICAL SPECIFICATIONS
V-WD-24P
Voltage/Frquency
120 V, 60 Hz
Current
8.5 A + 5.9 A receptacle
Max Airflow
200 m
3
/h; 117,72 cfm
Max Water lift
2530 mm H
2
O; 99.6” H
2
O
Tank Capacity
90 L; 23,78 Gal
Power cord length
0.4+12 m; 1.3+39.4 ft
Net Weight
58.43 lb / 26,5 kg
Sound pressure level [dBA]
70,0 dBA
Protection
IPX4
Pump Discharge elevation
Flow Rate
0 m / 0 ft
181,7 l/min / 48 GPM
1,52 m / 5 ft
166,6 l/min / 44 GPM
3,05 m / 10 ft
151,4 l/min / 40 GPM
4,57 m / 15 ft
136,3 l/min / 36 GPM
6,10 m / 20 ft
87,06 l/min / 23 GPM
7,62 m / 25 ft (MAX)
60,57 l/min / 16 GPM
Pump flow rate at listed discharge height: