ELECTRICAL
4Ć9
5300T MM382 (10–94)
TO REPLACE BATTERY VOLTAGE METER
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
FOR SAFETY: Disconnect the battery
connections before working on the machine.
1. Disconnect wires 9 and 17 from the positve
terminal, and wires 3, 28, 34, and 38 from
the negative terminal on the back of the
gauge using a 5/16 inch wrench.
2. Remove the two nuts that secure the
gauges mounting bracket against the panel,
using a 5/16 inch wrench.
3. When installing the replacement gauge,
position the gauge properly into its location
on the panel and connect wires 9 and 17 to
the positve terminal, and wires 3, 28, 34,
and 38 to the negative terminal on the back
of the gauge using a 5/16 inch wrench.
DO NOT over tighten the wire connections
or damage may occur to the gauge.
4. With the gauge properly positioned, install
the mounting bracket to the back of the
gauge and snug down the two nuts that hold
the gauge in place.
TO REPLACE MAIN POWER OR SOLUTION
ROCKER SWITCH
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
FOR SAFETY: Disconnect the battery
connections before working on the machine.
NOTE: When replacing a switch it is necessary to
also replace the splash guard.
1. Disconnect the harness plug to the switch
terminals. Note the switch terminal locations
in the harness plug before disconnecting.
Содержание 5300T
Страница 1: ...5300T MM382 Rev 00 10 94 Service Manual ...
Страница 4: ...GENERAL INFORMATION 5300T MM382 10 94 1 2 ...
Страница 16: ...CHASSIS 5300T MM382 10 94 2 2 ...
Страница 22: ...CHASSIS 5300T MM382 10 94 2Ć8 ...
Страница 24: ...SCRUBBING 5300T MM382 10 94 3Ć2 ...
Страница 54: ...SCRUBBING 5300T MM382 10 94 3Ć32 ...
Страница 56: ...ELECTRICAL 5300T MM382 10 94 4Ć2 ...