ELECTRICAL
4Ć8
5300T MM382 (10–94)
TO REPLACE MAIN CIRCUIT BREAKERS
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
FOR SAFETY: Disconnect the battery
connections before working on the machine.
1. Disconnect the wires from the circuit
breaker.
2. Carefully pry the retaining clip off the
backside of the breaker using a straight
screwdriver.
3. With the replacement breaker properly
positioned into its location on the panel, side
the new retaining clip securely into position.
4. Reconnect the wires to the circuit breaker.
See schematic in this section.
TO REPLACE BRUSH PRESSURE AND AMP
GAUGE
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
FOR SAFETY: Disconnect the battery
connections before working on the machine.
1. Disconnect wires 8 and 10 from the two
terminal studs on the back of the gauge
using a 5/16 inch wrench.
2. Remove the two nuts that secure the
gauges mounting bracket against the panel,
using a 5/16 inch wrench.
3. When installing the replacement gauge,
position the gauge properly into its location
on the panel and connect wire 8 and 10 to
the two terminal studs. DO NOT over
tighten the wire connections or damage may
occur to the gauge.
4. With the gauge properly positioned, install
the mounting bracket to the back of the
gauge and snug down the two nuts that hold
the gauge in place.
Содержание 5300T
Страница 1: ...5300T MM382 Rev 00 10 94 Service Manual ...
Страница 4: ...GENERAL INFORMATION 5300T MM382 10 94 1 2 ...
Страница 16: ...CHASSIS 5300T MM382 10 94 2 2 ...
Страница 22: ...CHASSIS 5300T MM382 10 94 2Ć8 ...
Страница 24: ...SCRUBBING 5300T MM382 10 94 3Ć2 ...
Страница 54: ...SCRUBBING 5300T MM382 10 94 3Ć32 ...
Страница 56: ...ELECTRICAL 5300T MM382 10 94 4Ć2 ...