Electrostatic Meter
TM-291
User’s Manual
HB2TM2910000
Страница 1: ...Electrostatic Meter TM 291 User s Manual HB2TM2910000 ...
Страница 2: ......
Страница 3: ... Instrument Description 2 5 Operation 3 5 1 Disable Auto Power Off Mode 4 5 2 Zeroing 4 5 3 Manual record mode 4 5 4 Display logs mode 5 5 5 Backlight Mode 5 5 6 Setting mode 5 6 Specifications 7 7 Maintenance or Repair 8 8 Battery Replacement 8 9 Product Disposal 8 ...
Страница 4: ...ecaution Caution Please refer to this manual Improper use may damage the meter and its components Complies with European Directive Do not operate in environments with flammable gas or humid environments Operating altitude up to 2000M Operating environment Indoor use Pollution degree 2 Clean with soft cloth when dirty such as glasses cloth Do not clean with chemicals and other solvents EMC EN61326 ...
Страница 5: ...peak value min value 5 Zero setting button 6 Power button 7 Function Setting button 8 Record readings up button 9 Display logs down button 10 Data hold 11 Backlight button 12 Grounding socket 13 Tripod nut 14 battery cover 15 Grounding wire 16 Crocodile clip 17 Protection cap ...
Страница 6: ... the anti static wrist strap Note that the anti static wrist strap is not an accessory and shall be prepared by yourself During the measuring for static voltage please fasten ceramic spacers on the fix threads besides the sensor Keep the sensor from the area under test for 1 inch 2 54 cm Click the Power button Make sure the meter is grounded before operating Aim the sensor point to the area under ...
Страница 7: ...button again to cancel 5 1 Disable Auto Power Off Mode The meter will automatically power off after powering on for about 15 minutes The LCD displays symbol at the mode If to disable the function press and hold the button for more than 2 seconds 5 2 Zeroing Prior to measuring the static voltage click the button for more than 2 seconds to clear the reading if an old reading survived on the LCD Note...
Страница 8: ... During measuring click button to turn on the backlight of LCD for 15 seconds and then turn off automatically 5 6 Setting mode Press button repeatedly and enter the settings of Step 1 to 4 sequentially Step 1 Set HI alarm 1 While the LCD displays SET1 HI symbol Press or to move digits press or button to change the settings 2 Quickly press button again and enter Step 2 Step 2 Set LO alarm 1 While t...
Страница 9: ... or button to change as or OFF 2 Quickly press button again and enter Step 4 Step 4 Clear memory 1 While the LCD displays SET4 dEL symbol press or button to change as or As is chosen press button to get memory cleared 2 Quickly press button to quit the settings status PS If to quit the settings status press button in any step ...
Страница 10: ...ration temperature and humidity 5 to 40o C 41 to 104o F 80 RH Storage temperature and humidity 10ºC to 60ºC 14 to 140 o F 70 RH Weight Approximately 210g Dimension 148 L x65 W x37 5 H mm Professional and precise static voltmeter with resolution of 0 001kV Function including Data lock HOLD Max value PEAK lock Min value PEAK lock Record REC the displayed value Display the logged data R M Zeroing ZER...
Страница 11: ...ery if not used for a long period of time in order to prevent battery leakage and causing damages to internal components 4 When the instrument failure only by the authorized service provider or return the original repair 8 Battery Replacement 1 Turn off the power 2 Open the battery cover at the back of the meter remove the batteries 3 Please insert six new 9V batteries according to the polarities ...
Страница 12: ...TENMARS ELECTRONICS CO LTD 6F NO 586 Ruiguang Rd Neihu Dist Taipei City Taiwan E mail service tenmars com http www tenmars com ...