Input
impedance:
about
10M
Ω
.
Results
might
be
unstable
at
mV
range
when
no
load
is
connected.
The
value
becomes
stable
once
the
load
is
connected.
Least
significant
digit
≤
±3
Max
input
voltage:
±600V,
when
the
voltage
≥
600V,
"OL”
symbol
appears
and
the
buzzer
goes
off.”
2.
AC
voltage
Range
Resolution
Accuracy
60.00mV
0.01mV
±(1.0%+3)
600.0mV
0.1mV
6.000V
0.001V
±(0.8%+3)
60.00V
0.01V
600.0V
0.1V
600V
1V
±(1.0%+3)
VFC
200.0V~600V
0.1/1V
±(4.0%+3)
Input
impedance:
about
10M
Ω
Display
true
RMS.
Frequency
response:
45Hz
~1KHz
(LPF
45~400Hz)
Accuracy
guarantee
range:
5
‐
100%
of
the
range,
shorted
circuit
allows
least
significant
digit
≤
10
Crest
factor
at
Max
range=3.0
(excluding
600V
range,
crest
factor=1.5)
Max
input
voltage:
600Vrms
3.
Resistance
measurement.
Range
Resolution
Accuracy
600.0
Ω
0.1
Ω
±(1.0%+2)
6.000k
Ω
0.001k
Ω
±(0.8%+2)
60.00k
Ω
0.01k
Ω
600.0k
Ω
0.1k
Ω
6.000M
Ω
0.001M
Ω
±(1.2%+3)
60.00M
Ω
0.01M
Ω
±(1.5%+5)
Measurement
result
=
reading
of
resistor
–
reading
of
shorted
test
leads
Open
circuit
voltage=1V
(Current=0.4mA)
Overload
protection:
600V
‐
PTC
4.
Continuity,
Diode
Position
Resolution
Remark
0.1
Ω
Set
Value:
Open
circuit:
resistance
≥
150
Ω
,
no
beep.
Well
‐
connected
circuit:
resistance
≤
10
Ω
,
continuous
beeps.
0.001V
Open
circuit
voltage
:3.2V
Silicon
PN
junction
voltage:
0.5
~
0.8V.
Overload
protection:
600V
‐
PTC