Tenda BCKP-0029 Скачать руководство пользователя страница 1

13 Altalef St. 

Yehud, Israel 56216 

Tel:  972 (3) 632-0533 
Fax: 972 (3) 632-0458 

 

www.tenta.com

 

919 Kifer Road 

Sunnyvale, CA 94086 USA 

Tel: (408) 328-1370 

Fax: (408) 328-1371 

 

 
 
 
 
 
 

PWRS-0026 

BCKP-0029 

 

6U CompactPCI 

Power Supply with UPS 

 

 
 
 
 
 
 

Содержание BCKP-0029

Страница 1: ...alef St Yehud Israel 56216 Tel 972 3 632 0533 Fax 972 3 632 0458 www tenta com 919 Kifer Road Sunnyvale CA 94086 USA Tel 408 328 1370 Fax 408 328 1371 PWRS 0026 BCKP 0029 6U CompactPCI Power Supply wi...

Страница 2: ...19 Document Revisions Rev Comment BY Date E0 Release Preliminary DG 11 25 00 E0 1 Additions and corrections DG 12 07 00 E1 0 Release Windows utility added UPS time defaults changed DG 04 16 01 E2 0 Up...

Страница 3: ...pecifications 8 C Front Panel Indicators 8 D Power Specification 8 E On Board Fuses 9 IV Power Supply Card 10 A Power Supply Block Diagram 10 B UPS Option 11 C Functionality 11 V Logic Board 12 A LOGI...

Страница 4: ...4 of 19 I Ordering Information Part Number Description AS00026 01 Power supply card 130 watts 6U M type connector AS00030 01 UPS logic board 6U AS00043 01 Power supply with UPS logic board AS00029 01...

Страница 5: ...I Power Distribution board with UPS The power supply board provides power signals through M type connector to the CompactPCI back plane It may be used stand alone or with the optional UPS logic and ba...

Страница 6: ...The power supply can be used stand alone or combined with items 2 3 for a full UPS system 1 PS Power conversion AC DC 90 132 180 264 VAC 15V DC DC conversion of 15V to 5V 3 3V 12V 2 LOGIC Charger for...

Страница 7: ...rid female connector for J1 cPCI BUS and J5 signal distribution on logic board Front Panel 262mm Height X 50mm Width x 2mm Thickness with power and status indication LED s Weight 900g BACKUP PCB Dimen...

Страница 8: ...s Label Function 12V 12 VDC supply green 12V 12 VDC supply green 15V 15 VDC supply green 5V 5 VDC supply green 3 3V 3 3 VDC supply green NT SHT DWN NT in shutdown state green blinking PWR FAIL Loss of...

Страница 9: ...PWRS 0026 User Manual Page 9 of 19 E On Board Fuses Fuse Voltage Value F1 12V 3A F2 12V 0 375A F3 3 3V 5A F4 5V 10A F5 5V 10A...

Страница 10: ...h no additional PCB modifications Three DC DC converters provide conversion of the 15V AC DC output to all required DC levels one for 5V one for 3 3V and one for 12V A Power Supply Block Diagram AC DC...

Страница 11: ...l for power sequence between HOST and UPS control when in serial handshake mode BACKUP is a cPCI card which is inserted from the back side of the cage behind the second slot and contains the battery a...

Страница 12: ...nd handshake with NT via serial bus or CPCI bus for power shut down sequence 3 Routing power signals from the BACKUP board to PS during power failure The power failure detection circuit is responsible...

Страница 13: ...UPS control system PCI to LOCAL Bridge Serial Interface J5 PCI Connector J1 PCI Connector PCI Interface signals Battery related signals Transition connector power fault staus indication LED s Staus si...

Страница 14: ...nals with a selected COM port The battery pack is capable of powering a 130 watt system for a minimium of 5 minutes The 12 VDC battery pack consists of 10 1 2 VDC cells in series and can supply 10 8 a...

Страница 15: ...ram Battery Pack CPCI J5 connector Switch on off circuit Serial port control signals battery on off battery power battery power NT UPS derial interface Serial Handshake Signal Connector Ref Signal nam...

Страница 16: ...and activated through the Control Panel utility the UPS is enabled and begins charging CHRG COMP will be orange Upon being fully charged CHRG COMP will turn green The system continuously checks for a...

Страница 17: ...POWER_OK 0 FAIL_MODE 1 if POWER_OK 0 for more than FAIL_TIME If FAIL_MODE and UPS_ENABLE 1 provide UPS battery power until time UPS_TIME or REMOTE_UPS_SHUTDOWN is received On standard NT shut down UP...

Страница 18: ...supply power for shutdown Offset 0x4 Size 32bit Values 10000ms to 300000ms Scale Factor 127ms Default 120000ms Updated by NT program Name FAIL_TIME Description Acceptable duration of power loss before...

Страница 19: ...itable installation environment and for the purposes it was designed Any damages caused by natural disasters such as fire flood wind and lightning are not covered For more information please contact T...

Отзывы: