105
Sidekick
®
Plus Test Set
Saving Test Results
To save a modem connection result:
1. Press the
9 (Save)
key after the connection is
successful. The menu bar will change to display the
following features:
•
F1 Save
saves the current connection result.
•
F2 Recall
displays a previously saved connection
result.
•
F3 Delete
deletes a previously saved connection
result.
•
F4 Exit
returns to the previous menu.
2. Press
F1 Save
. Enter a name for the result with the
keypad.
3. Press
F4 Done
when complete.
Notes:
• The saved record only contains the link level results.
Results from the Upper Layer tests are not saved.
• Saving results for bonded VDSL circuits can take up
to 30 seconds.
Displaying Saved Results
To display a saved modem connection result:
1. Press the
9 (Save)
key to enter the Save/Recall
menu. The menu bar will change to display the
following features:
•
F1 Save
saves the current connection result.
•
F2 Recall
displays a previously saved connection
result.
•
F3 Delete
deletes a previously saved connection
result.
•
F4 Exit
returns to the previous menu.
2. Press
F2 Recall
. The unit will provide a list of saved
results.
3. Select the correct result using the up (
2
) and down
(
8
) keys.
4. Press
F4 Select
when complete. The previously
saved result will be displayed on the screen.
5. The up (
2
) and down (
8
) keys step to the next and
previous result pages.
6. When finished examining the data, press the
F3
Show Live Data
key to return to live data.