Blizzard Enclosure User Manual
page 24
Important – RDM and RDM Integration
DEC3.2’s RDM implementation allows system integrators to set up remote control and status
monitoring of all attributes and sensors, including:
•
Relative Humidity
•
Air Temperature
•
PCB Temperature
•
Lamp Current
•
Elapsed Lamp Hours
•
Lamp Relay Status
•
Fan Relay Status
•
Heater Relay Status
•
DMX Status
•
DMX Start Address
•
DMX Personality (RDM Mode)
•
Device Type
•
Device Label
•
Software Version
RDM is an effective and powerful tool for commissioning and monitoring an
installation, particularly in large systems. For further guidance, we
recommend you consult a qualified RDM system integrator. If you don’t
have one in your neighborhood, go to www.tempestlighting.com, and click on the RDM and RDM
Integration bug on the FAQ page for some useful contacts. Tempest Lighting warrants DEC3.2 to
be compliant with the RDM standard, but is not an RDM systems integrator, and can offer only
basic guidance on RDM utilization.