Blizzard Enclosure User Manual
page 22
RDM Connections
RDM refers to ANSI E1.20, a control protocol in the entertainment industry gaining popularity and
essentially an “extension” of DMX512. The use of RDM is optional, and uses the same RS485 cable
connection as DMX512, so no additional wiring is required.
It is the responsibility of the user to ensure that any DMX splitters or other routing devices used
are rated for RDM as well as DMX use.
Power Connections
IMPORTANT Tempest enclosures are supplied for either 120VAC 50/60Hz, or 208-
240VAC, 50/60Hz operation. Tempest Lighting is not liable for damage or
failure to operate correctly due to connection to an inappropriate electrical
supply.
ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A QUALIFIED
ELECTRICIAN, IN COMPLIANCE WITH LOCAL NORMS AND STANDARDS.
Note: wire colors may differ depending on applicable electrical standards. European wire colors are shown here.
MAKE SURE THAT TERMINAL SCREWS ARE FULLY BACKED OUT BEFORE INSERTING WIRES
Projector Supply
(split mode)
Enclosure Supply
(100-250VAC 50/60Hz)
Fan 1
Fan 2
Heater(s)
Projector
receptacle
Cut here for split
supply operation