Operating manual

VS 5500 plus
Heating controller

Содержание VS 5500 plus

Страница 1: ...C Dok Nr 111045 33 2007 entwurf Operating manual VS 5500 plus Heating controller ...

Страница 2: ...tting the clock time 12 2 3 Check temperatures and operating mode 13 2 4 Temporarily deactivation of room temperature influence 13 2 5 Setting the weekly clock programme 14 2 6 Setting the clock programme exception day 15 2 7 Setting the room temperature 16 2 8 Setting the automatic holiday programme 17 3 Settings in the service level 18 3 1 CLEAR function reload factory settings 18 3 2 Setting le...

Страница 3: ...ide measured temperatures of Roomtemperature heating mode adoption with the right rotary knob Daytime Domestic hot water production on off Time bar The selected heating program is shown Comfort modus Normal modus Reduced modus b1 Time bloc 1 b3 Time bloc 3 Clapet closed Claped open Tendency mixing valve OPEN CLOSE Heating circuit pump desired room temperature b2 Time bloc 2 Display und operating e...

Страница 4: ...4 Notes Display und Bedienelemente ...

Страница 5: ...rried out continuously according to the set value Reduced heating No clock programme Reduced heating is carried out according to the set value No warm water heating Holiday Heating Warm water heating OFF Frost room protection function active Heating OFF Summer operation Heating is OFF Warm water heating is active according to the weekly clock programme Frost room protection function active Manual ...

Страница 6: ...witched on during the re duction phase the party symbol blinks If the party function is activated during heating the party symbol appears When switching to reduced heating the party symbol blinks until the end of the reduced heating period The duration of the party function is set in setting 3 09 The party function can be stopped at any time by pushing the button again Operating lock The active op...

Страница 7: ... settings 3 10 1 5 Temporary interruption of the holiday programme Cover closed The holiday programme can be interrupted in two ways 1 Activate party function see 1 3 Party function operating lock page 6 2 Select the operating mode Weekly clock programme or Clock programme exception day At the next change to reduced hea ting within the automatic holiday pro gramme the controller returns automatica...

Страница 8: ... time period setting 5 67 factory setting 60 mins 1 7 Heating limit Cover closed 1 2 1 As soon as the outside temperature is higher than the set Heating limit for heating Setting 3 04 the controller switches to Heating OFF Summer operation The pump runs delayed to the value in the setting 7 03 When the temperature drops 2 K below the Heating limit for heating heating operation is switched on again...

Страница 9: ... a switch In this way the SR 5811 is disconnected from the electricity supply 2 Communication between the SR 5811 and the VS 5511 plus is interrupted After around 60 secs the VS 5511 plus starts to function in Manual emergency operation The heat generator temperature is controlled by the boiler thermostat The heating circuit pump is continu ally active The warm water heating function is continuall...

Страница 10: ...me so that the data can be reloaded CLEAR By pushing the CLEAR button the set tings and the clock programme can be reset back to the factory settings See chapter 2 5 page 14 and Chapter 3 1 page 18 Functions on the left hand side All settings are valid for both heating circuits mixed and direct at the same time Date and time Query data Weekly clock programme Clock programme exception day normal co...

Страница 11: ...elect the function The right hand arrow is already at 2 Push the button the date blinks 3 The date can now be set by turning the right rotary knob 4 The new date must be confirmed by pushing the button Rapid turning of the knob makes the setting go faster 3 4 Year Month Day ...

Страница 12: ...ry knob 2 Select the function Time with the right rotary knob 3 Press the push button the time dis play blinks 4 The time can now be set using the right rotary knob 5 Confirm the new time with the push button Rapid turning of the knob makes the setting go faster 3 4 5 Year Month Day Daytime ...

Страница 13: ...ressed for five seconds until the arrow jumps to the lowest symbol 2 Switch on room temperature influence Hold the push button pressed again for five seconds until the right hand arrow has returned to the originally selected function or at the next change to reduced hea ting the arrow jumps automatically back to the original function If the room temperature has been reached and the function Room i...

Страница 14: ...should be set to the same start and finishing time and confir med using the push button Programme other days or daily periods as per points 2 to 5 The programme is only saved memorised after all time periods b1 b2 b3 have been set and confirmed with the push button The newly programmed time bars are then shown 5 6 Resetting of factory values for the weekly clock programme 6 Using a fine point pres...

Страница 15: ...ds b2 and b3 Unused time periods should be set to the same start and finishing time and confir med using the push button The programme is only saved memorised after all time periods b1 b2 b3 have been set and confirmed with the push button The newly programmed time bars are then shown 5 Reloading of factory values for the clock programme exception day 5 Using a fine point press the CLEAR button un...

Страница 16: ... 2 Using the right rotary knob select the room temperature or to be changed 3 Activate the setting with the push button The temperature display blinks 4 Set the required room temperature using the right rotary knob 5 Confirm this setting with the push button 3 4 5 Room temperature normal comfort reduced ...

Страница 17: ...iday period Confirm the setting with the push button The holiday programme is saved To interrupt the holiday programme see 1 5 Temporary interruption of the holiday programme page 7 Check the holiday programme 1 Select the function 2 Using the right rotary knob start of the holiday period end of the holiday period and the time for the end of the holiday period can be checked Delete the holiday pro...

Страница 18: ...emperature 3 04 Heating limit when heating 3 05 Heating limit when reduced 3 06 Pre heating time optimised 3 07 Room temp influence 3 08 Heating limit as per flow temperature set value 5 02 5 67 Warm water temp set value Warm water pre heating time 3 1 CLEAR function reload factory settings WARNING Unintentional use of the CLEAR but ton deletes plant specific settings which can lead to malfunction...

Страница 19: ...ure at an outside temperature of 20 C is set here base point The heating curve 3 02 Steepness of heating curve 0 0 5 0 1 2 The heating curve shows the relationship between the heating flow and the outside temperature 3 03 Maximum flow temperature 30 90 75 C The flow temperature should not be higher than the set value This is not a safety function When safety functions are required e g with floor h...

Страница 20: ...influence 0 20 4 K K If the measured room temperature deviates from the set value e g due to other heat sources such as sunshine the con troller corrects the flow temperature by a corresponding value The set value indicates the number of Kelvin flow temperature correction with a room temperature deviation of 1 K Higher room temperature reduced flow temperature Lower room temperature increased flow...

Страница 21: ...o control the pump switch must also be installed 3 04 Heating limit during heating 0 40 20 C If the outside temperature exceeds the set value for heating the heating circuit switches to summer operation The pump runs at a reduced rate according to the value set in 7 03 When the temperature drops to 2K below the set value heating is started again 3 05 Heating limit reduced operation 10 20 10 C Only...

Страница 22: ...e when the difference between the calculated flow temperature and the room temperature is lower then the set value The pump is reduced by the value given at setting 7 03 If the difference increases to 2 K above the switch off value heating is started again 10 OFF 2 function active recommended for control strategies and 3 4 Setting level 5 Domestic hot water supply Set ting Function Setting range F...

Страница 23: ...1 5 03 5 04 5 05 5 07 6 00 6 04 6 05 7 00 7 03 7 13 Duration party function Room protection temperature Room temperature controller adjustment time Room temperature controller hold back time Room temperature actual value correction Follow up time warm water supply Legionella protection temp Day selection legionella protection Warm water supply parallel or with priority over heating Minimum heat ge...

Страница 24: ...ion and allows a future deviation to be corrected at an early stage Recommended settings Floor heating 6 radiator heating 3 3 81 Room temperature actual value correction 5 0 5 0 0 K This setting allows the measured room temperature shown in the display to be changed e g for adjustment to measured values of another temperature measuring device 4 2 Setting level 5 Domestic hot water supply Set ting ...

Страница 25: ...Proportional mixer range 10 60 30 K The P range dictates via which set actual value deviation the OPEN and CLOSE commands are continually given not pulsating A small set value creates a larger change in the mixture with increasing deviation The mixing circuit reacts quickly For actuators with long running times A large set value creates a smaller change in mixture with increasing deviation The mix...

Страница 26: ...e to flow temperature set value 5 K The set value for the heat generator is higher than the required flow temperature set value by this value during heating operations 5 3 Frost protection function Function Factory setting Unit Frost protection function 2 C The frost protection function is active in the chosen operating mode Heating OFF If the outside temperature drops below 2 C the heating circul...

Страница 27: ...direct heating circuit 1 warm water supply 1 heat generator with a one stage burner Operation is carried out only via the SR 5811 6 3 Hydraulic Application alternatives 1 Without heat generator Do not attach the boiler sensor 2 Without warm water supply Do not attach the warm water sensor 3 Direct heating circuit without mixer Do not attach the flow sensor Set the setting 3 01 lower by 5 K Outside...

Страница 28: ... and protec tion must be carried out and must confirm to local regulations The VS 5511 plus must have a conti nual electricity supply in order to ensure functioning at all times Peripheral switches must be limited to emergency or main switches which are usually continually switched on Before start up it should be checked that all components are connected correctly to the electricity supply If stro...

Страница 29: ...connection of the SR 5811 Make sure that all cables are disconnected from the electricity supply before you begin work on the wiring The controller must be dis connected before installing or remo ved the operating unit Never touch the wires printed back or connec tions of the operating unit Connecting cables should be fed through the cable ducts provided avoid coiling and twisting of cables Juncti...

Страница 30: ...itched on 1 Open the cover 2 Press the RESET button bottom left next to the party button The SR 5811 will now be initialised The following can be seen on the display 1 The software number e g 510 000 2 This is followed by the software ver sion e g SW 0 1 3 All segments of the display will then be shown If the controller then returns to the nor mal display the internal function test was successful ...

Страница 31: ...ntroller not switched on External switch is set to manual emergency operation Check the fuses switch the controller on Change the switch for manual emergency operation SR 5811 deactivate Push the RESET button If necessary carry out a plausibility test with a second controller Error display Communication to VS 5511plus is interrupted Check connecting cable Has the controller been installed properly...

Страница 32: ...0 C Running reserve 24 h after 3 operating days 9 2 Technical data VS 5511 plus Supply voltage 230 VAC 10 50 60 Hz Performance take up 2 VA Sensor circuit voltage 12 V insulation strength 4 KV Ambient temperature 0 C 55 C Sensor cable length cross section max 100 m 0 75 mm2 Bus interface OpenTherm 2 cable bus twisted interchangeable Output switching capability Mech ports right 1 7 250 VAC 6 2 A 50...

Страница 33: ... 9 4 Explanation of terms and abbreviations b1 b2 b3 Time periods which can be set for the clock programme h Hours Actual value Temperature measured K Kelvin difference in temperature min Minutes Net Mains electrical supply 230V VAC OpenTherm 2 cable data bus for heating technology Set point value Temperature set by the operator or calculated by the controller which controls the actual value set b...

Страница 34: ...34 Notes ...

Страница 35: ...11 eco 28 L left rotary knob 10 M Manual emergency operation 9 P Party function operating lock 6 R RESET 10 right rotary knob 10 Room temperature setting 16 Room temperature adjust temporarily 6 Room temperature influence switch off temporarily 13 Room temperature adjustment direct heating circuit 21 Room temperature adjustment mixed heating circuit 19 S Select operating mode 5 Sensor resistance v...

Страница 36: ...Manufacture or distribution ...