Troubleshooting Outgoing Calls
NET-PATHm does not go off-hook.
Possible Cause:
•
Incorrect database. Event is not programmed, is not programmed correctly, cur-
rent time is not in the Action window, or event duration is too long.
•
No App loaded.
Incoming calls are not received at the Polling and Analysis Center.
Possible Cause:
•
Bad database. Incorrect telephone number.
•
Modem at the receiving end is not set for auto-answer.
•
Restricted telephone line. Contact your local telephone representative.
Call was received at the Polling and Analysis Center, but did not have a carrier.
Possible Cause:
•
Non-compatible or defective modem at the Polling and Analysis Center.
•
The modem at Polling and Analysis Center is not in data mode.
•
You selected an incorrect database option.
Call received at Polling and Analysis Center, modem connected, but message not
received.
Possible Cause:
•
Bad database. Incorrect protocol flag.
•
Bad telephone line. Contact your local telephone representative.
•
Incorrect receiving option (parity, speed, stop bits, data bits)