LLS SENSOR
LLS sensor series liquid level sensors are solid-state capacitive devices with no moving
parts. The sensors use capacitive technology to produce accurate liquid level measurements of
standard factory grade DIESEL OIL and PURE GASOLINE (BENZINE) carbon fuels.
The LLS sensor liquid level sensors are strictly prohibited to use in any liquids which are not
the factory grade carbon fuels or contain: BIOFUEL, METHANOL, ETHANOL, UREA and similar
aggressive components in pure form or as additives for factory grade carbon fuels for use in
INTERNAL COMBUSTION ENGINES. Operating media – Diesel fuel (oil), pure gasoline (benzene).
IMPORTANT!
The power supply is 10-50 VDC stabilized. The wrong polarity (-) or (+)
connection of power supply will damage or destroy the device. Prohibited for
test or use in water and any other liquids, which are not factory grade carbon
fuels. Fit the plastic insulation cap on the end of the central rod after
installation accordingly to installation guide. To be installed, calibrated, tested
only by qualified authorized person (installer, technician, mechatronic).
21.1
Specifications
Supply voltage, DC V
10...50*
Current consumption, mA (for 12/24 V)
25/50
Operation temperature, Celsius degrees
-40...+85
Working mode
continuous
Weight, kg
< 2.0
Working pressure
atmospheric
21.2
Hardware
Operation principle: capacitive.
Output: RS-232.
Standard probe lengths: 700, 1000, 1500 mm.
Optocoupler isolation on both power and signal circuits.
21.3
Connecting LLS to FMB630
In order to use LLS fuel counter the newest firmware version is needed which can be
obtained from Teltonika or a representative. Firmware is updated over GPRS or using cable
update method (see chapter 4 for more information).
The LLS fuel sensor must be connected to the FMB630 device. The FMB630 -LLS fuel
sensor schemes are shown below Figure 122.