Teltonika FMB120 Скачать руководство пользователя страница 13

 

13 

FMB120 | 

Wiki

 

Electrical characteristics 

Table 6 Electrical characteristics 

CHARACTERISTIC DESCRIPTION  

VALUE 

MIN.   TYP.   MAX.  

UNIT  

SUPPLY VOLTAGE

 

Supply Voltage (Recommended Operating 
Conditions)  

+10    

+30  

V  

DIGITAL OUTPUT (OPEN  DRAIN  GRADE)

 

Drain current (Digital Output OFF)  

 

 

120  

µA  

Drain current (Digital Output ON, 
Recommended Operating Conditions)  

 

0.1  

0.5  

A  

Static Drain-Source resistance (Digital Output 
ON)  

 

400   600  

mΩ 

 

DIGITAL INPUT

 

Input resistance (DIN1)  

47  

 

 

kΩ 

 

Input resistance (DIN2)  

51.7   

 

kΩ 

 

Input resistance (DIN3)  

150 

 

 

kΩ 

 

Input voltage (Recommended Operating 
Conditions)  

0  

 

Supply 
voltage  

V  

Input Voltage threshold (DIN1)  

 

7.5  

 

V  

Input Voltage threshold (DIN2)  

 

2.5  

 

V  

Input Voltage threshold (DIN3)  

 

2.5  

 

V  

 

 

 

 

 

ANALOG  INPUT

 

Input voltage (Recommended Operating 

Conditions), Range 1  

0  

 

+10  

V  

Input resistance, Range 1  

 

38.45   

kΩ 

 

Measurement error on 12V, Range 1  

 

0.9  

 

 %  

Additional error on 12 V, Range 1  

 

108    

mV  

Measurement error on 30 V, Range 1  

 

0.33    

 %  

Additional error on 30 V, Range 1  

 

88  

 

mV  

Input Voltage (Recommended Operating 

Conditions), Range 2  

0  

 

+30  

V  

Input resistance, Range 2  

 

150    

kΩ 

 

Measurement error on 12 V, Range 2  

 

0.9  

 

 %  

Additional error on 12 V, Range 2  

 

108    

mV  

Measurement error on 30 V, Range 2  

 

0.33    

 %  

Additional error on 30 V, Range 2  

 

88  

 

mV  

OUTPUT SUPPLY VOLTAGE  1-WIRE

 

Supply voltage  

+4.5    

+4.7  

V  

Output inner resistance  

 

7  

 

Ω 

 

Output current (U

out

 > 3.0 V)  

 

30  

 

mA  

Short circuit current (U

out

 = 0)  

 

75  

 

mA  

Содержание FMB120

Страница 1: ...Quick Manual v1 6 GPRS GNSS tracker with Bluetooth FMB120...

Страница 2: ...t the battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic c...

Страница 3: ...3 FMB120 Wiki Know your device Figure 1 FMB120 device view...

Страница 4: ...0 V DC Digital input channel 3 4 DIN 2 Digital input channel 2 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 DOUT 1 Digital output channel 1 Open collector ou...

Страница 5: ...5 FMB120 Wiki Figure 3 FMB120 Wiring scheme Wiring scheme 1 Automotive relay 1...

Страница 6: ...r Wiki how to enter it later in Teltonika Configurator Make sure that Micro SIM card cut off corner is pointing forward to slot 3 Connect battery as shown to device Position the battery in place where...

Страница 7: ...r installation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Con...

Страница 8: ...y 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update f...

Страница 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Страница 10: ...on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable...

Страница 11: ...Blinking every two seconds Sleep mode Blinking fast for a short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characterist...

Страница 12: ...thout battery 40 C to 85 C Storage temperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery disc...

Страница 13: ...V Input Voltage threshold DIN1 7 5 V Input Voltage threshold DIN2 2 5 V Input Voltage threshold DIN3 2 5 V ANALOG INPUT Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance R...

Страница 14: ...ess which is inaccessible to the operator All related devices must meet the requirements of EN 62368 1 standard The device FMB120 is not designed as a navigational device for boats Do not disassemble...

Страница 15: ...is necessary to read the User s Manual before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equip...

Страница 16: ...product Replaced with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODU...

Отзывы: