35
Figure 23 System Settings Configuration
When Vehicle Generator is working supply voltage is usually 2V – 4V volts higher than when it is
not. While generator is working, it is too late block engine. Ignition is 1, when power voltage is
within high and low levels
Example:
High Level: 15000
Low Level: 13000
If External Voltage 14V, then ignition is ON.
If External Voltage 12V, then ignition is OFF.
If External Voltage 16V, then ignition is OFF.
6.3.3.2
GSM Settings
6.3.3.2.1
GPRS
‘GPRS’ defines main parameters for FM6320: destination server Domain (can be entered
either IP or domain name) and port. Also both TCP and UDP protocols are supported. Server
Response Time defines the time how long device will wait for response from server before device
denies the connection between FM6320 and server.
Figure 24 GSM->GPRS Settings Configuration