Содержание CPE9000

Страница 1: ...LTE Outdoor CPE9000 October 2017 System Manual ...

Страница 2: ... shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this manual or equipment supplied with it Warranties and Disclaimers All Telrad Networks Ltd Telrad Networks products purchased from Telrad Networks or through any of Telrad Networks authorized resellers are subject to the following warranty and produc...

Страница 3: ...D FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT WITH RESPECT TO THE SOFTWARE UNITS OF PRODUCT INCLUDING ALL THE SOFTWARE DELIVERED TO PURCHASER HEREUNDER ARE NOT FAULT TOLERANT AND ARE NOT DESIGNED MANUFACTURED OR INTENDED FOR USE OR RESALE IN APPLICATIONS WHERE THE FAILURE MALFUNCTION OR INACCURACY OF PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE PHYSICAL OR ENVIRONMENTAL DA...

Страница 4: ...OT BE LIABLE TO THE PURCHASER OR TO ANY THIRD PARTY FOR ANY LOSS OF PROFITS LOSS OF USE INTERRUPTION OF BUSINESS OR FOR ANY INDIRECT SPECIAL INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND WHETHER ARISING UNDER BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES b TO ...

Страница 5: ...ual LTE LTE Status Basic LTE Status PDN LTE Cell Selection LTE PIN LTE Default PDN LTE Multiple PDN LTE PLMN Selection LTE Advanced LTE Cell Lock Network Network Status Network WAN Setting NAT Mode Network WAN Setting Tunnel Mode Network WAN Setting Bridge Mode Network WAN Setting Router Mode Network LAN Setting Network QoS Available in NAT Tunnel Router Mode Network Routing Available in Tunnel Ro...

Страница 6: ... Filter Firewall L3 DATA Filter Firewall L2 Filter Firewall Access Restriction Management Management Account Management Language Management Device Setting Management Restore Default Management Device Log Management Software Management RM Settings Monitoring Monitoring Status Monitoring Iperf Monitoring Diagnostic Tools About About Status ...

Страница 7: ...ty and product liability terms and conditions Exclusive Warranty a Telrad Networks warrants that the Product hardware it supplies and the tangible media on which any software is installed under normal use and conditions will be free from significant defects in materials and workmanship for a period of fourteen 14 months from the date of shipment of a given Product to Purchaser the Warranty Period ...

Страница 8: ...AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION NON INFRINGEMENT AND ACCURACY OF INFORMATION GENERATED ALL OF WHICH ARE EXPRESSLY...

Страница 9: ...e is not authorized to transmit without a grant and ships with TX disabled It is the responsibility of the CPI to populate the CPI database and obtain a grant before the Device is permitted to Transmit Location will be recorded by the professional installer and reported to the CPI database along with the other parameters listed in the above table FCC Radiation Exposure Statement This equipment com...

Страница 10: ...ssembly and should understand related local building codes Network administrators should have a solid understanding of software installation procedures for network operating system and troubleshooting knowledge LTE CPE has a web GUI which supports http https protocol it could be used to configure the CPE settings through the web browser by user s PC Please refer to the following pages for more det...

Страница 11: ...PE9000 Product Highlights TD LTE 3GPP Release 10 UE Category 6 Supports wired LAN port High gain 15dBi embedded Antenna Device Management Web TR69 SNMP IP67 environmental rating fully ruggedized suitable for the harshest outdoor deployment scenarios ...

Страница 12: ... MCS28 QPSK 16QAM 64QAM UL MCS1 MCS28 QPSK 16QAM 64QAM Uplink 64QAM with Telrad eNodeB L1 MIMO TM1 TM2 TM3 TM4 TM8 L2 L3 Multiple APN PLMN and Cell Selection Authentication USIM and SIM function QoS Non GBR GBR MTU Size Layer 2 1 600 bytes Layer 3 1 500 bytes Outdoor CPE 9000 Electrical Physical Specifications Dimensions HxWxD 260 x 250 x 80 mm Weight 1 2 Kg 2 6 lbs Physical Interface LAN 1x100M 1...

Страница 13: ...5 C 40 to 131 F Humidity 5 to 95 non condensing ESD Rating 15KV Power Consumption 6 7W Regulatory Compliance 2 X GHz CE 2 3 2 4 GHz and 2 5 2 7 GHz FCC 2 5 2 7 GHz 3 X GHz CE 3 4 3 8 GHz FCC 3 55 3 7 GHz requires domain proxy only B48 supported IC 3 475 3 7 GHz PoE Adapter Specification Power Source 100 240VAC Output Power PoE 56V 0 45A User Interfaces Data only 1xLAN RJ45 Maximum cable length 100...

Страница 14: ...g Kit 1 If any item of mentioned above is missing or damaged please contact our customer support immediately Connectors The Outdoor LTE CPE CPE9000 has following connectors from left to right 1 One RJ 45 connector for connecting to the PoE adaptor 2 LED indicator inside and SIM card slot for inserting SIM card 3 A grounding screw on the rear panel ...

Страница 15: ...15 LED Indicators LED name Location Color LED Behavior Status Indication LED List MAIN power Blue ON Power On OFF Power Off Ethernet status Yellow Steady ON Detect Ethernet Device Connected Blinking Detect IAD OFF No Ethernet action ...

Страница 16: ...tion LTE Outdoor CPE should be pole mounted outdoors and aligned so its antenna faces the nearest LTE eNodeB When selecting a suitable location for the unit consider these guidelines Place LTE Outdoor CPE as high as possible to achieve the best possible linkquality Place the LTE Outdoor CPE away from power and telephone lines Avoid placing LTE Outdoor CPE too close to any metallic reflective surfa...

Страница 17: ...ory Using the clamp 1 Thread the M10 100mm bolt through a spring washer flat washer and the bracket holes 2 With the connector facing downward attaché LTE Outdoor CPE to a 1 4 pole 3 Attach the bracket to the other side of the pole 4 Thread the M10 100mm bolts through both holes on either side and tighten the nuts Connecting the Cables ...

Страница 18: ...for RJ 45 connectors to prepare the wires Insert them into the appropriate pins and use the tool to crimp the connector Make sure to do the following Remove as small a length as possible of the external jacket Verify that the external jacket is well inside the sealing cover when connected to the unit to ensure good sealing Pull back the shield drain wire before inserting the cable into the RJ 45 c...

Страница 19: ...e gland plug from the gland nut Open the sealing gland nut and remove it Don not disassembles the gland base from the bracket Insert the cable into the sealing gland base and connect it to the RJ 45 connector at the bottom of the CPE Make sure the connector is completely inserted and tightened Insert the rubber bushing on the cable into the gland base ...

Страница 20: ...o air bubbles Slide the cold shrink sleeve on top of the connector Make sure that the sleeve covers both cable connector and unit connector Pull the cord slowly to shrink the sleeve Indoor Connection 1 It is assumed that the RJ 45 cables are already connected to the LTE outdoor CPE Assemble an RJ 45 connector with a protective cover on the other end of the LTE outdoor CPE cable 2 Connect the other...

Страница 21: ...ied with the ODU Otherwise LTE Outdoor CPE may be damaged 4 Plug in PoE into power line The device will start the booting process Please wait for a minute to let the booting process complete 5 Select Local Area Connection Status from Windows task bar and click Properties ...

Страница 22: ...er Manual P 22 Local Area Connection Status 6 Double click on the Internet Protocol TCP IP Local Area Connection Properties 7 Select Obtain an IP address automatically Obtain DNS server address automatically and click OK ...

Страница 23: ...LTE Outdoor CPE User Manual P 23 Internet Protocol TCP IP Properties 8 By now the device should have got IP address from your DHCP server ...

Страница 24: ...w to verify CPE has a successful connection to the LTE eNodeB This can be verified by observing the signal strength LEDs Please refer LED Indications section in Introduction chapter of this manual to find the location of these LEDs on the ...

Страница 25: ...tion Now you can start browsing the Internet Web Interface Login to Web GUI Users devices are assumed in CPE LAN side Please follow the steps below to configure your device through the web interface Step1 Open the Web browser Ex Internet Explorer Firefox or Chrome and enter the default IP address of CPE which is http 192 168 254 251 Web browser ...

Страница 26: ...ks and each block contains its own feature A concise description is presented in the block Users can click on it to enter Detailed Configuration Page to see the complete settings or tweak the configuration Detailed information about this page will be stated below Brief Summary Page Brief Summary Page After you ve opened up GUI page the first page you see is Brief Summary Page This window shows all...

Страница 27: ... about all functions of LTE CPE each block is a link to Detailed Configuration Page Ex Click Network you can go to Network main menu with sub menu like DHCP or Port Forwarding and other settings about Network Detailed information for each block is in the below table GUI Interface ...

Страница 28: ...peruser or Enduser Button of REBOOT Button of LOGOUT this logo is an example It can be customized if needed Mode LTE Operator Either APN Name LTE mode Signal More bar means better signal Disconnect no signal Signal Only an example the real signal depends on local connection environment ...

Страница 29: ...ce Name Telrad_2C3263 is just an example In general it looks like XXXXX_YYYYYY XXXXX Service Provider YYYYYY Last six words of WAN MAC Device Up Time The uptime from the bootup of LTE CPE Uplink Downlink Data Rate Uplink Downlink Rate of the LTE CPE Service Provider The service provider of this LTE CPE Generic is just an example Firmware Version Firmware Version of this LTE CPE ...

Страница 30: ...ration Page Main Menu Show the current main menu Sub Menu Clickable can jump to another Sub Menu under the same Main Menu Quick Panel Each icon in Quick Panel represents a Main Menu when users click it a list of Sub Menu will be popped up By using Quick Panel users can quickly jump to the desired Sub Menu under other Main Menu For example if the user wants to do Restore Default Click Management Ic...

Страница 31: ... LTE Signal bar more bar means better signal means no signal or disconnection When CPE cannot Detect SIM card the ICON will appear Login identity could be Superuser or Enduser Button of REBOOT Button of LOGOUT Button to go Back to brief information Page Pop up Sub Menu in Quick Panel ...

Страница 32: ...he menu structure given below LTE Status Cell Selection PIN Default PDN Multiple PDN PLMN Selection Advanced Cell Lock Network Status WAN Setting LAN Setting QoS Port Management DSCP MGMT Service Firewall Basic L3 MGMT Filter L3 DATA filter L2 Filter Access Restriction Management Account Language Device Setting Restore Default Device Log Software RM Settings Monitoring Status Iperf Diagnostic Tool...

Страница 33: ...nk downlink status All the setting about LTE placed here such as LTE Earfcn and PIN code PDN multiple PDN PLMN search and Cell Lock Display in Brief Summary Page Display in Quick Panel of Detailed Configuration Page Menu Structure LTE Status Cell Selection PIN Default PDN Multiple PDN PLMN Selection Advanced Cell Lock ...

Страница 34: ...mation LTE Status State Possible states are connecting and connected Network Operator It shows APN name Technology LTE Connection Time the accumulated time after the state is connected LTE Information RRC State Device Init Detect LTE module SIM Detecting As titled ...

Страница 35: ...signal receive quality CINR0 The quality of the signal of path0 CINR1 The quality of the signal of path1 SINR0 Signal to interference plus noise ratio of path0 SINR1 Signal to interference plus noise ratio of path1 TX Power Transmission power PCI Physical cell identity Cell ID Cell Identity a part of cell global identification eNodeB ID Identity of connected eNodeB UpLink Status Data Rate The uplo...

Страница 36: ...ket data network PDN Type The connection type of each packet data network Authentication Type The Authentication type of each packet data network Connected The Connection status of each packet data network IP Address The IP address of each packet data network The first Cid of PDN should be considered as default The Cid sequence would be started from 2 ...

Страница 37: ...ng full band would take much longer time than Dedicated Earfcn Band 48 Type DL Earfcn or Dl Frequency Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded LTE Band 48 and Earfcn Frequency Range are just an example Real number is determined by the user s requirement ...

Страница 38: ...ge PIN Enable PIN Enable Disable PIN code protection Change PIN Change the PIN code Remaining Attempts remaining times to try PIN code Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 39: ...e than three times maximum numbers of attempts allowed your SIM card will become PUK locked status Please contact your service provider for further unlock instruction Remaining Attempts is just an example Real number is determined by user s SIM card If users want to change the PIN code of SIM card they need to enable Enable PIN code check function in advance ...

Страница 40: ...need to specify an APN Name Authentication Type There are None PAP and CHAP to choose from If choosing PAP or CHAP users need to specify the username and password PDN Type Only support IPv4 right now Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 41: ... Type There are None PAP Password authentication protocol or CHAP Challenge Handshake Authentication Protocol to choose from If choosing PAP or CHAP users need to specify the username and password Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded APN name can t be empty The type of the authentication i...

Страница 42: ...echnique to keep connecting to ISP for CPE If CPE search PLMNs it will be recorded in the table below Survey button to scan all the PLMN around the CPE Index Number of PLMN PLMN ID Identification of PLMN and depends on eNodeB e g 00101 Operator Name of ISP Technology e g LTE ...

Страница 43: ...ontent only to interested receivers MFBI is Multi Frequency Band Indicator Allow CPE connect to another Band with overlap frequency For Example CPE set Band 38 can connect to eNodeB with Band 41 TM8 TDD is support dual layer beamforming Enable eMBMS User can enable this service via check this box MFBI Support User can enable this service via check this box TM8 TDD support User can enable this serv...

Страница 44: ...define in the list The list contains up to 10 in priority to others cells Detected Cell Survey button to scan all surrounding coverage cell Index Number of Cell DL Earfcn Downlink EUTRA Absolute radio frequency channel number PCI Physical cell identity RSRP dBm Reference signal receiving power RSRQ dB Reference signal receive quality Lock Specific Cell ...

Страница 45: ... the list DL Earfcn Downlink EUTRA Absolute radio frequency channel number PCI Physical cell identity Delete Remove specific cell lock Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded While use Cell Lock please do survey for scanning surrounding eNodeB coverage cell by click survey button ...

Страница 46: ...onfigure network function such as WAN setting LAN Setting QOS Port Management DSCP and MGMT Service Display in Brief Summary Page Display in Quick Panel of Detailed Configuration Page Menu Structure Network Status WAN Setting LAN Setting QoS Port Management DSCP MGMT Service ...

Страница 47: ...MAC Gateway DNS Server Time Server of LTE CPE and statistics of TX and RX Bytes and Packets of WAN interface These values may differ from Single PDN to Multiple PDN in NAT Mode with Multiple PDN enable and Separate WAN MGMT and Data Interface will get two WAN IP one for MGMT Management packets to CPE one for Data Date transfer to LANside ...

Страница 48: ...n Lease Status Table This section shows all clients who get IP from DHCP server in LTE CPE Network Status Lease Status Table Refresh button Click the Refresh button to trigger refresh manually Auto button This button will update the status information periodically ...

Страница 49: ...E Outdoor CPE User Manual P 49 The period can be set from GUI Refresh Time in page Management Device Setting The address and TX RX bytes are all examples here Real values depend on the local ISP provider ...

Страница 50: ... Bridge and Router Mode The following pages will show how to configure NAT mode Changing the Operation Mode needs reboot to take effect A pop up window will ask users to Reboot or Continue If you select Reboot CPE would reboot right away If you select Continue CPE would not reboot automatically you need to reboot it manually ...

Страница 51: ...Host Name currently no function Host Name Telrad_2C3263 Just an example here in general it will be like XXXXX_YYYYYY XXXXX Service Provider YYYYYY Last six words of WAN MAC WAN MGMT and DATA Interface Users can choose Separate to use different Interface for MGMT and Data traffic or just use Combine which means using same interface for MGMT and Data Separate only works in LTE mode Below are two sim...

Страница 52: ...ne is selected in WAN MGMT and Data Interface data and management traffic share the same interface If Separate is selected another WAN IP address subnet mask and gateway address to configure data traffic will be shown Two WAN IP one for MGMT other for DATA WAN MTU This value is Maximum Transmission Unit The size of a single packet can only be as large as MTU If the size of the packet exceeds MTU t...

Страница 53: ...AN MGMT and DATA Interface users need to choose from 2 8 for WAN DATA connection Please make sure this PDN is configured beforehand in page Mobile Network Technology LTE Multiple PDN NTP1 2 Users can specify two NTP servers in IP or Domain name format For example 45 79 167 181 or 0 us pool ntp org Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to ...

Страница 54: ...ludes NAT Tunnel Bridge and Router Mode The following pages will show how to configure Tunnel mode Changing the Operation Mode needs reboot to take effect A pop up window will ask users to Reboot or Continue If you select Reboot CPE would reboot right away If you select Continue CPE would not reboot automatically you need to reboot it manually ...

Страница 55: ...lly acquire configuration information from a DHCP server If Static mode is selected users have to manually enter the required information in below fields Host Name Currently no function WAN IP Address Subnet Mask Gateway Address These values are un editable when users select DHCP in Connection Mode WAN MTU This value is Maximum Transmission Unit It is the largest size of a single packet DNS1 2 Dom...

Страница 56: ... SUPPORTED BY TELRAD Network WAN Setting Operation Mode users have NAT Tunnel Bridge and Router Mode to choose from The following pages show how to configure Bridge mode Changing the Operation Mode needs reboot to take effect A pop up window will ask users to Reboot or Continue If you select Reboot CPE would reboot right away If you select Continue CPE would not reboot automatically you need to re...

Страница 57: ...sk Gateway Address These values are un editable when Connection Mode is DHCP and editable when Connection Mode is Static WAN MTU This value is Maximum Transmission Unit It is the largest size of a single packet DNS1 2 Domain Name Server It is editable when users select Static in Connection Mode Otherwise these values will be given by DHCP server MultiPDN connection for Data Only in Bridge Mode If ...

Страница 58: ...format For example 45 79 167 181or 0 us pool ntp Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded Network WAN Setting Router Mode Operation Mode users have NAT Tunnel Bridge and Router mode to choose from The following pages will show how to configure Router mode ...

Страница 59: ...e is selected users have to manually enter the required information in below fields Host Name Currently no function Host Name Telrad_2C3263 Just an example here in general it will be like XXXXX_YYYYYY XXXXX Service Provider YYYYYY Last six words of WAN MAC WAN IP Address Subnet Mask Gateway Address These values are un editable when Connection mode is DHCP and editable when Connection mode is Stati...

Страница 60: ...ify two NTP servers in IP or Domain name format For example 45 79 167 181 or 0 us pool ntp org Changing the Operation Mode needs reboot to take effect A pop up window will ask users to Reboot or Continue If you select Reboot CPE would reboot right away If you select Continue CPE would not reboot automatically you need to reboot it manually Pop up windows for reboot confirm Cancel button Reset fiel...

Страница 61: ... Operation Mode this IP only means a back up IP address When users cannot link to CPE web GUI due to the dynamic IP address users can use the back up IP address to link to CPE web GUI instead If users choose other tunnel mode this IP means LAN side domain and Web GUI IP address This IP will change IP prefix in DHCP Server Port Forwarding and Port Trigger DHCP Server Available in NAT Tunnel RouterM...

Страница 62: ...s assigned by DHCP server DHCP Ending IP Address The ending IP address assigned by DHCP server Notice that Ethernet share the same DHCP server the range of IP addresses should not be narrow Otherwise clients cannot get LAN IP addresses From ISP When the checkbox is ticked clients set CPE as DNS server but CPE will only act as a DNS relay The following picture is captured from a PC in LAN DNS Serve...

Страница 63: ...mary secondary and tertiary DNS Network DHCP Server not From ISP 1 1 1 1 2 2 2 2 and 3 3 3 3 are examples DHCP Lease Time The life time of the IP assigned by DHCP server range 2 minutes 365days Lease Reservation Table This table records the mapping of MAC and IP addresses Clients with the specific MAC address in the table would get the corresponding IP address Click Add button to add a new mapping...

Страница 64: ...r Manual P 64 Example 11 22 33 44 55 66 192 168 254 222 are examples here Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 65: ...on to add a new rule clicking Delete icon to delete the rule Enable QoS Enable disable QoS Enable VoIP QoS Set generic rules for VoIP service like UDP and TCP port 5060 11720 Name Name of the rule Priority Priority of each rule 1 is the highest priority 255 is the lowestpriority Enable Enable Disable the rule Interface The interface that the rule is applied to Min Rate The guaranteed sending rate ...

Страница 66: ... satisfy 60 kbps requirement 3 If 200 kbps is needed the traffic will only get 100 kbps due to max rate constraint Mode Only protocol QoS Protocol TCP UDP ICMP and ANY ANY includes TCP UDP and ICMP Source Destination PortRange and Source Destination IP Range The port and IP range of the traffic that needs QoS Source Destination Port and Source Destination IP can be an empty value which means DON T...

Страница 67: ...ing Click Add button to add a new rule clicking Delete icon to delete therule Name Name of the rule Enable Enable Disable the rule Interface The interface that the rule is applied to Gateway The gateway of the routing rule Metric The metric of the routing rule It s the distance related to the route Destination IP The destination IP or a subnet Netmask The subnet mask of the rule ...

Страница 68: ...s with the port number in these ranges packets will be forwarded to the designated LAN IP and LAN Port This function is very useful when a server is set up in LAN side like FTPserver Click Add button to add a new rule clicking Delete icon to delete therule Protocol TCP or UDP WAN Port The range of WAN port LAN Port The range of LAN port LAN IP Enter the IP which desires to receive forwarded packet...

Страница 69: ...03 are reserved for management use The priority of port forwarding rules is higher than DMZ Users can set DMZ and it will not influence port forwarding Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 70: ... forwarded to the host which uses trigger port Port P does not open if port triggering is not activated Click Add button to add a new rule clicking Delete icon to delete the rule Application Name Name of the port trigger rule Triggered Range Traffic passing through the port in the triggered range would automatically open the forwarded port in the forwarded range The ports in the triggered range ar...

Страница 71: ...User Manual P 71 Enable Enable Disable the rule Delete Delete the rule Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 72: ...t specifies a simple scalable and coarse grained mechanism for classifying and managing network traffic and providing quality of service QoS on modern IP networks DSCP value range is between 0 63 Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 73: ...P in WAN If DDNS is enabled clients can connect to CPE through DDNS Host Name Enable DDNS Enable Disable DDNS When DDNS is enabled select the DDNS service provider you registered from the drop down list and configure the following parameters DDNS Service Provider DDNS User Name DDNS Password and DDNS Host Name Cancel button Reset fields to the last saved values Apply button Commit the changes made...

Страница 74: ...n the LAN can link to CPE HTTPs service Users can set the port used by HTTPs service Clients in the WAN side are able to link to CPE HTTPs service when HTTPs service is on and allow HTTPs login from WAN in firewall section is on Please note that the clients in LAN and WAN may use different ports to link to CPE HTTPs service Import WEB Certificate The certificate is used by HTTPs service users can ...

Страница 75: ...ge is only for LAN if users want to login to GUI from WAN it needs to enable Allow Https login from WAN in Firewall Basic Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 76: ...ll page allows user to configure firewall to block and grant some network access Display in Brief Summary Page Display in Quick Panel of Detailed Configuration Page Menu structure Firewall Basic L3 MGMT Filter L3 DATA filter L2 Filter Access Restriction ...

Страница 77: ...twork MGMT Service HTTPs Login Port from WAN As titled DMZ IP Address All network traffic from WAN is forwarded to this IP address in LAN Redirect ICMP to the host The function will be activated if DMZ is enabled Tick the checkbox to have CPE pass ICMP messages to hosts or un tick the checkbox to let the CPE reply ICMP messages Multicast Filter If the checkbox is ticked multicast packets would be ...

Страница 78: ... Manual P 78 they pass through Enable UPnP IGD Active UPnP function on CPE Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 79: ...or Deny to allow the access or reject the traffic Interface Select which interface users want to block allow the traffic from Available options are WAN LAN or BOTH Log Select Log to have log records or No Log to disable it users would not see it log is printed in the console Protocol Protocol to filter Available options are TCP UDP ICMP or ANY Port The port number to filter Src IP The source IP to...

Страница 80: ...IP to form a subnet Enable Enable Disable the rule Delete Delete the rule You need to press the apply button to take effect Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 81: ...te therule Name The name of the rule Action Permit or Deny to allow or to reject the traffic Interface Select which interface users want to block allow the traffic from Available options are WAN LAN or BOTH Log Select Log to have log records or No Log to disable it users will not see it the log is printed in the console Protocol Protocol to filter Available options are TCP UDP ICMP or ANY Port The...

Страница 82: ... It would be used with Src IP to form a subnet Dst Mask It would be used with Dst IP to form a subnet Enable Enable Disable the rule Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 83: ... Log to have log records or No Log to disable it Users will not see it the log is printed in the console Ether Type EtherType is a two octet field in an Ethernet frame which is used to indicate which protocol is encapsulated in the payload of an Ethernet frame Enter the Ether Type code Range 0600 FFFF according to the protocol you use VLAN ID IEEE 802 1Q is the networking standard that supports Vi...

Страница 84: ...Src Mask The source Mask to filter Dst Mask The destination Mask to filter Enable Enable Disable the rule Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded The format of MAC address should be XX XX XX XX XX XX ...

Страница 85: ...y all the traffic from 10 00 to 12 00 Second users can deny devices with certain MAC address accessing the network Third users can deny clients accessing certain URL Click Add button to add a new rule clicking Delete icon to delete therule After pressing Apply button the access restriction rule is graphically presented in the following manner Click to edit and click to fixit Firewall Access Restri...

Страница 86: ...ork Blocked Device Block the device with specified MAC address or block packets with specified IP range Blocked Reason 1 block all traffic 2 block packets with specified keyword Cancel button Reset fields to the last saved values Apply button Commit the changes made and save to the CPE device some services will be reloaded ...

Страница 87: ... to configure the main system parameters such as password language device time name etc Display in Brief Summary Page Display in Quick Panel of Detailed Configuration Page Menu structure Management Account Language Device Setting Restore Default Device Log Software RM Settings ...

Страница 88: ...change the default username and password for Superuser and Enduser There should be at least 9 characters for the password Click Apply to save this change Tick the checkbox Enable to enable the account Apply button Commit the changes made and save them to the CPE device Cancel button Reset fields to the last saved values ...

Страница 89: ...nagement Language The language page allows user to switch the language used in the web Select the language you want from the drop down list and then click Apply button to apply the changes Apply button Commit the changes made and save them to the CPE device ...

Страница 90: ...C button to synchronize the time of CPE with PC Time Zone as titled Auto Adjust for Daylight Saving Time Enable this option if your location observes Daylight Savings Time Timeout Refresh Setting Management Session Timeout Automatic logout after the period Range 0 10 Minutes 0 means never expired GUI Refresh Time When users press auto button in any page the page refresh ...

Страница 91: ...to CPE from any device in the internal network by entering the device name on the address bar Current Device Name Display the current device name New Device Name A field to update your current device name Apply button Commit the changes made and save them to the CPE device Cancel button Reset fields to the last saved values ...

Страница 92: ...elect Management Restore Default to go back to the factory default settings Restore Default Click Restore button to clear all users configuration and restore to factory default settings Restore to default settings Window Last Good Configuration Save Last Good Save the current configuration ...

Страница 93: ...se the storage device is broken The green check indicates the investigation is passed Integrity Check Window Rollback Settings CPE saves two firmware with possible different versions in CPE CPE would choose one of them Users can press rollback to switch to use another firmware A Rollback confirming window pops up and then starts rebooting to have change taken effect Rollback confirmation window Re...

Страница 94: ...utput to Remote server And CPE also defines different Severity Level of output data it can help engineer to get the specific logging data they want Syslog Target User can choose the output target to Web or Remote syslog server IP Only available at Remote Status User can determine the Remote syslog server IP via this Severity User can log seven severity level of sys log for engineer to debug Save b...

Страница 95: ... Manual P 95 Refresh button Click the Refresh button to trigger refresh manually Auto button This button will update the syslog information periodically Apply button Commit the changes made and save them to the CPE device ...

Страница 96: ...t process will be started to let the change taken effect The ipkg file you have uploaded will be shown in the table below the device software version Management Software Upgrading Window After pressing the Upgrade button it will automatically reboot the CPE and upgrade the firmware with the specified file You will be prompted to re login to the CPE after the upgrade is complete Configuration Backu...

Страница 97: ...usly saved configuration file and then click Restore button to restore the system to the previous settings Management Software Upgrading Window A window will be popped up to let users to key in the passphrase when users save restore the configuration Please note that the entered passphrases need to be consistent when users do save restore process Enter Passphrase Window ...

Страница 98: ...door CPE User Manual P 98 Press the Restore button CPE will automatically reboot and adjust the configuration with the uploaded file Users will be prompted to re login to the CPE after the process is complete ...

Страница 99: ...ual P 99 Management RM Settings Management RM Settings Disable In this page users can set up the remote management RM Type Disable Select Disable to disable the remote management RM Type SNMP Simple Network Management Protocol ...

Страница 100: ...mmunity string is correct the server responds with the requested information SNMP Read Write Community SNMPv2 only The SNMP Community string is like a user id or password that allows access to a router s or other device s statistics If the community string is correct the server responds with the requested information SNMP Trap SNMPv2 only A way for an agent to send a asynchronous notification to t...

Страница 101: ...Requirement A remainder to let users know that CPE needs to reboot to have something taken effect SNMP Access from LAN Enable Disable SNMP Access Domain Enable Disable SNMP Access Domain IP Address The IP address of the accessdomain SNMP Access Domain Netmask The subnet mask for the accessdomain SNMP Engine ID SNMPv3 only A unique identifier for the agent SNMP Engine Boots SNMPv3 only A count of t...

Страница 102: ...LTE Outdoor CPE User Manual P 102 SNMP Engine Table SNMPv3 only ...

Страница 103: ...g the word ACS stands for Auto Configuration Server ACS URL The URL or IP address of the ACS ACS UserName The username for authentication when CPE connects to ACS 20 alphanumeric characters allowed ACS UserPassword The password for authentication when CPE connects to ACS 20 alphanumeric characters allowed Enable Periodic Inform Enable Disable CPE to ask ACS periodically for configuration update Pe...

Страница 104: ...ername which matches this field 20 alphanumeric characters allowed Connection Request Password When ACS connects to CPE CPE also needs to challenge ACS for authentication ACS has to send the password which matches this field 20 alphanumeric characters allowed If ACS does provisioning there is no need for users to set connection request username password because ACS would send that to users ...

Страница 105: ...andard for activation of terminals in OMA Open Mobile Alliance it is designed for management of small mobile devices such as mobile phones PDAs and palm top computers Global Settings Enable OMA Debug Message Enable it and then the debug message is printed in the console Provisioned Configuration of the CPE enabling and disabling features Model ID Defined Select customize or read from system Model ...

Страница 106: ...f the CPE It is used for DM server to connect to CPE Client Password The password of the CPE It is used for DM server to connect to CPE Client Nonce The CPE and OMA DM server use nonce to authenticate each other if user selects MD5 as an authentication algorithm in Client Auth Type field 20 alphanumeric characters allowed Client Authorized Type Select the encryption algorithm used by DM server to ...

Страница 107: ...ted Session Client Initial Session If you press this button the client would ask the server for tasks to do immediately DRMD Authorized Msg Server URL Assign a hyperlink for server site Apply button Click this button to reset the device settings to factory default Cancel button Reset fields to the last saved values ...

Страница 108: ... device status such as CPU loading and memory usage and provides the interface to use the tools such as Iperf ping and traceroute Display in Brief Summary Page Display in Quick Panel of Detailed Configuration Page Menu structure Monitoring Status Iperf Diagnostic Tools ...

Страница 109: ...ta is used to compute the CPU memory and network statistics Reset button Reset CPU Memory utilization and Uplink Downlink data rate CPU Utilization CPU Current Usage CPU Max Usage CPU Min Usage Memory Utilization Memory Current Usage Memory Max Usage Memory Min Usage Uplink Data Rate Current Data rate Max Data rate Min Data rate Downlink Data Rate ...

Страница 110: ...a rate Max Data rate Min Data rate System Information Firewall The status of firewall It is either ON or OFF Device Uptime The accumulated time after the device is powered on Restart Reason Device auto User Forced Operator Forced Software Upgrade ...

Страница 111: ...nt Settings Status Enable Disable Iperf Last Measurement Date Time As titled Server Address As titled Server Port As titled Management Port To do bi directional transmission CPE opens management port to let the server transmit data to itself Management Time The time to do Iperf recording Protocol Type TCP or UDP TCP Client Number Protocol Type TCP The number of simultaneous TCP connection to the s...

Страница 112: ...LTE Outdoor CPE User Manual P 111 Result Uplink Latency only UDP Downlink Latency only UDP Uplink Speed Downlink Speed ...

Страница 113: ...sult of ping and traceroute will be presented in DiagnosticResult Settings Status Enable Disable the tool Diagnostic Type ping or traceroute IP Address Domain The IP address or domain name for CPE to connect Ping Count Diagnostic Type Ping Stop after sending Ping Count packets Packet Size Diagnostic Type Ping As titled Ping Timeout Diagnostic Type Ping Time to wait for the response packet back to ...

Страница 114: ...on such as Service Provider Product Name Model ID Serial ID IMEI IMSI Firmware version Firmware Creation Date Bootrom Version Bootrom Creation Date and LTE Support Band Display in Brief Summary Page Display in Quick Panel of Detailed Configuration Page Menu structure About Status ...

Страница 115: ...ovided by CPE Model ID The ID used by the manufacturer Serial ID The ID used by the operator IMEI International mobile equipment identity IMSI international mobile subscriber identity Firmware Version The version of the firmware Firmware Creation Date As titled Bootrom Version The version of the bootloader Bootrom Creation Date As titled LTE Support Band The supported LTE band ...

Страница 116: ...908 1 V7 1 1 EN 301 908 13 V6 2 1 EN 62311 2008 EN 301 489 1 V1 9 2 EN 301 489 24 V1 5 1 EN60950 1 2006 A11 2009 A1 2010 A12 2011 EN60950 22 2006 In Italy the end user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links and or for supplying public access to telecommunications and or network services T...

Страница 117: ...akohastele sätetele English Hereby name of manufacturer declares that this type of equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Español Spanish Por medio de la presente nombre del fabricante declara que el clase de equipo cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva ...

Страница 118: ... Alulírott gyártó neve nyilatkozom hogy a típus megfelel a vonatkozó alapvetõ követelményeknek és az 1999 5 EC irányelv egyéb elõírásainak Polski Polish Niniejszym nazwa producenta oświadcza że nazwa wyrobu jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999 5 EC Português Portuguese Nome do fabricante declara que este tipo de equipamento está conforme co...

Страница 119: ...LTE Outdoor CPE User Manual P 118 ...