DC Power Consumption - SL871L-S
State & Constellation
Typ
Max
Units
Acquisition
GPS Only
61
76
mW
Navigation/Tracking
GPS Only
54
69
mW
Vbatt
25
66
μ
W
Operating temperature is 25°C.
Supply voltages were nominal 3.3 VDC.
Table 23: SL871L-S Power Consumption
Digital Interface Signals
I/O Signal Levels
Warning: Note that I/O voltage ranges are different from supply
voltages VCC and VBATT.
Warning: Several different logic levels are utilized by the digital
signal interfaces of the module as shown in the tables below.
9.3.1.1.
Logic Levels - Inputs
RX, RX1, Reset-N, ANT-SC-N, and ANT_OC
Signal
Symbol
Min
Typ
Max
Units
Input Voltage (L)
Vil
0
0.5
V
Input Voltage (H)
Vih
1.9
3.4
V
Note: These inputs have an internal pullup of 40 k
Ω
to 190 k
Ω
.
Do not drive the Reset-N line high.
Table 24: Input Logic Levels: RX and Reset-N, & Ant Sense
Force-On (SL871 and SL871L only)
Signal
Symbol
Min
Typ
Max
Units
Input Voltage (L)
Vil
0
0.25
V