SL871 Family Product User Guide
1VV0301170 Rev. 9
Page 24 of 89
2021-07-15
Not Subject to NDA
Power Management - Command Summary
$PMTK Cmd
Type
State
Full Power
To Exit (wake) from a commanded low-power state
225
0
Full
Perpetual Backup
To wake:Force_ON Signal (MT3333 only)
225
4
Backup
Standby
To wake:Character to Rx
161
0
Stop
161
1
Backup
Periodic (MT3333 only)
223
-
Specify Extended Parameters
225
1
Backup
225
2
Standby
Always Locate (MT3333 and old MT3337 only, Not on new MT3337E)
223
-
Specify Extended Parameters
225
8
Standby
225
9
Backup
GLP (MT3333 only)
262
0
Disable
262
3
Enable
Table 4: Power Management - Command Summary
Full Power Continuous Mode
The module starts in full power continuous mode when powered up. This mode uses the
acquisition engine to search for all possible satellites at full performance, resulting in
the highest sensitivity and the shortest possible TTFF.
The receiver then switches to the tracking engine to lower the power consumption when:
•
A valid GPS/GNSS position is obtained
•
The ephemeris for each satellite in view is valid
To return to Full Power mode from a low power mode, send a $PMTK225,0*2B
command just after the module wakes up from its previous sleep cycle.
If power is removed from Vbatt, then Time, Ephemeris, Almanac, EASY, EPO data, and
PMTK configuration data will be lost. If Vbatt is present, no data will be lost.
Backup Mode (Perpetual) (SL871 and SL871L only)
In the backup mode, the internal Power Management Unit is turned off, leaving only
BBRAM and the RTC powered up. This reduces power consumption to the minimum
required that still provides data retention to enable hot and warm starts.