5 DATA RETENTION
The receiver is capable of retaining data elements under the various initialization types.
If Vcc is maintained, no data will be lost.
If Vcc is removed, the battery will maintain power until it is exhausted. If the battery is exhausted
Vcc may need an additional power cycle to properly boot.
The following table shows which data elements are saved under each type of initialization.
To erase EPO data, use the
$PMTK127
command.
Data Retention (1)
Initialization Almanac Ephemeris EPO Host EPO EASY Position Time
Power Cycle
Y
Full Cold
Start
Y
(3)
Cold Start
Y
Y
Y
Y (3)
Warm Start
Y
Y
Y
Y
Y
Y
Hot Start
Y
Y
Y
Y
Y
Y
Y
Reacquisition
Y
Y
Y
Y
Y
Y
Y
Note 1: Commanded parameters (e.g. UART speed, feature enables, etc.) are not
preserved over a power cycle.
Note 3: The standard definition of “Cold Start” does not allow time to be preserved.
Use “Full Cold Start” to compare with other vendor’s products’ “Cold Start”.
Table 5-1 Data Retention