background image

 

 

24

 H

O

U

R

 Z

O

N

E

 (N

.C

.)

TE

LC

O

 D

IA

LE

R

T

R

1 2 3

5 6

1 2

SIM

1
2
3
4
5
6
7
8

Power LED

EARTH
GROUND

LED Mode

Toggle Button

4

L

E

D

s

 2

-5

Signal (dBm)

NO

SVC

< -110

> -110

> -100

> -90

> -80

> -70

> -60

RSSI (bars)

NONE

1

2

3

System Status LEDs (RSSI Mode)

OFF

BLINKING

ON

System Status 

LEDs

Alarm Panel

Battery 

Connector

Acceptable RSSI Range

BATTERY

Battery wire 

should be at 

least ¼ inch 

apart from 

AC wires

Not Used

Not Used

1 2

1

3

2

4

1

2

1

2

3

4

5

6

1

2

1

2

3

AC

+

-

OPTIONAL

BATTERY

STC2

(N.C)

STC1

(N.O.)

GND IN

TRIP

2

3

4

5

6

6

7

G

R

E

E

N

R

8

8

1

T

R

E

D

INCOMING

TELCO

RJ31X

24

 H

O

U

R

 Z

O

N

E

 (N

.O

.)

TELGUARD

Digital TG-4

GND DC

1 FLASH = ACFC LOW/MISSING AC
                   LPF LOW DC INPUT
2 FLASH = LBC LOW BATTERY
3 FLASH = LFC LINE FAULT
4 FLASH = NSC NO SERVICE
5 FLASH = RFC RADIO FAILURE
6 FLASH = DTF DIAL TONE FAIL
7 FLASH = PPF PNL PRES FAIL

L

E

D

 1

OFF

NOT ACTIVATED

ACTIVATED

ON

System Status LEDs (Normal Mode)

ACTIVATION DENIED (DISABLED)

FLASHING

ACTIVATION

L

E

D

 2

OFF

FLASHING

SYSTEM 
TROUBLE

NO TROUBLE

TROUBLE:

L

E

D

 3

OFF

ON

PANEL COMM

PANEL ON-HOOK (PRIMARY)

PANEL ON-HOOK (BACKUP)

L

E

D

 4

OFF

IDLE

WAITING FOR RESPONSE FROM 
TCC

ON

ACTIVATION DENIED

FLASHING

TMC COMM

L

E

D

 5

OFF

IDLE

RADIO INITIALIZING

ON

RADIO COMMUNICATING

FLASHING

RADIO STATUS

PANEL OFF-HOOK

FLASHING

L

E

D

 6

L

E

D

 7

L

E

D

 8

OFF

NOT USED

OFF

NOT USED

NOT USED

NOT USED

AC NOT CONNECTED

UNIT MAY BE RECEIVING 
POWER FROM DC/BATTERY

OFF

POWER LED

FLASHING

STANDARD LINE SECURITY ENABLED

(2 FLASHES EVERY 5 SECONDS)

AC

(12V 800MA)

AC CONNECTED TO UNIT

ON

 

 
 

Telguard Model TG-4 

QUICK INSTALLATION GUIDE 

Installation Summary 

There are seven steps in installing Telguard properly.  

IF YOU DO NOT 

PROCEED IN THE ORDER AND MANNER PRESCRIBED, YOU MAY 
NOT COMPLETE THE INSTALLATION IN THE TIME ALLOCATED.

   

S

TEP 

1:

 

R

EGISTER FOR 

C

ELLULAR 

S

ERVICE

 

Register the unit online through 

www.telguardonline.com

, by 

completing the Online Registration Form at 

www.Telguard.com

.  Telular 

requires this information to activate the unit. 

S

TEP 

2:

 

L

OCATE 

U

NIT AND 

M

EASURE 

S

IGNAL 

S

TRENGTH 

(RSSI) 

First, you will be confirming that Telguard has adequate cellular signal strength. Press the LED 
Mode Toggle button, LEDs will now indicate signal strength. Minimum recommended is 2 

½ 

(2 

on solid and the third flashing).

 

). The LED Mode will reset to normal automatically after 10 

minutes or after pressing the LED Mode Toggle button again. 

S

TEP 

3:

 

T

RANSMIT 

P

ANEL 

A

LARMS OVER THE 

T

ELCO 

C

ONNECTION

 

Next, you will verify that the alarm panel is programmed properly.  This step is important to 
verify that the alarm panel is programmed with valid account code and central station 
information before transmitting signals through the cellular network. 

S

TEP 

4:

 

P

ROGRAM

,

 

A

CTIVATE 

&

 

T

RANSMIT 

P

ANEL 

A

LARMS OVER 

THE 

C

ELLULAR 

R

ADIO 

N

ETWORK 

 

Next, you will be connecting the alarm panel's digital dialer output to Telguard and verifying that 
alarm signals can be reliably sent through Telguard over cellular to the central station digital 
receiver.  The incoming Telco line is not connected to Telguard during this step. A minimum of 
two alarm signals must be transmitted. Activation is confirmed when LED 1 is illuminated. 

(NOTE:

 THE FIRST ALARM WILL ACTIVATE THE UNIT AT THE 

T

ELULAR 

C

OMMUNICATION 

C

ENTER

,

 IT WILL NOT GO TO THE 

C

ENTRAL STATION

,

 ALL SIGNALS AFTER THE FIRST ARE 

SENT TO THE 

C

ENTRAL 

S

TATION

S

TEP 

5:

 

C

ONNECT 

S

UPERVISORY 

T

RIP 

O

UTPUTS

 

Next, you will wire Telguard's supervisory trip outputs to the alarm panel and then test. 

S

TEP 

6:

 

C

ONNECT 

T

RIP 

I

NPUT 

(

OPTIONAL

Optionally, you can wire an external relay input to the trip input lead and ground, and test. 

S

TEP 

7:

 

C

OMPLETE THE 

I

NSTALLATION

 

Your last step will be to attach earth ground, and permanently mount the unit.  

 

 

 

 

 

 

 

 

 

 

 

 

            