INSTALLATION DIAGRAM
Configuration With Plixus Engine Only
PORT 1
PORT 2
PORT 3
PORT 4
CONFERENCE NETWORK (CN)
48 V / 2A OUT (4x)
Plixus Engine
Room Equipment
televic
POWER
48vDC
Plixus Power Supply
FLOOR
MICROPHONE
MUTE
!
"
#
$
%
&
'
FLOOR
MICROPHONE
MUTE
!
"
#
$
%
&
'
FLOOR
MICROPHONE
MUTE
!
"
#
$
%
&
'
Figure 1-24
Example of Plixus network with engine only
For a setup where you only need an engine, connect the units directly to the conference ports of the Plixus
engine. Daisy chain the different units in the branch. If your system contains uniCOS units, you need an
external power supply.
Only mix compatible units in one branch. For more information on which units you can combine see "Plixus
component properties" on page 50. In this table you can also see the power consumption, which you need
to know how many units you can have in one branch. Use the power calculator tool to validate your
configuration ("Power supply design" on page 61).
Configuration With Network Extender
DAISY-CHAIN NETWORK EXTENDERS
When you daisy-chain network extenders, you can have a maximum of 32 network extenders ( eight per
branch and this for the four Plixus conference ports).
INSTAL L ATIO N DIAG R AM
5 5
Содержание Plixus AE-R
Страница 1: ...conference PLIXUS INSTALLATION GUIDE...
Страница 85: ...Figure 1 46 How to attach the uniCOS T MM10 to a fixed surface ATTACH UNICOS T MM10 TO A FIXED SURFACE 85...
Страница 88: ...10 Remove UniCOS F MM 7 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 88...
Страница 90: ...6 7 POWER 2x RJ 8 9 click click 10 INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 90...
Страница 91: ...Remove UniCOS F MM 10 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 91...
Страница 99: ...Figure 1 57 How to detach the nameplate from the mounting bracket and bottom plate MOUNT THE NAMEPLATE 99...
Страница 162: ...TELEVIC CONFERENCE Leo Bekaertlaan 1 8870 Izegem Belgium 32 51 30 30 45 GET IN TOUCH...