GENERAL INSTALLATION GUIDELINES
The following installation design rule apply for one branch / loop powered only by the Plixus engine (internal
48 Vdc power supply) or an external Plixus Power Supply:
A maximum of 100 W
A specific maximum of devices per product family per branch / loop
A maximum cable length between two units of 100 m
Units Per Branch / Loop
Depending on the type of unit we advise to add a maximum amount of devices per branch. This is to ensure
that the last device in the branch receives enough power (only for devices powered over Ethernet) and limit
delay data transmission.
In the table below you can see the maximum allowed devices per branch.
Device type
Max. number per branch
Confidea T/F
20
Confidea FLEX
20
Confidea F channel selector
30
uniCOS F/MM (externally powered)
30
uniCOS F/MM7 (powered over cable)
6
uniCOS F/MM10 (powered over cable)
5
Lingua Interpreter Desk
8
uniBOX (externally powered)
30
uniBOX (powered over cable)
6
Video IN / OUT
8
Plixus NEXT
8
Confidea G3 WCAP
8
Confidea F-DIV-C
8
Plixus Nameplate
8
G ENER AL INSTAL L ATIO N G UIDEL INES
5 3
Содержание Plixus AE-R
Страница 1: ...conference PLIXUS INSTALLATION GUIDE...
Страница 85: ...Figure 1 46 How to attach the uniCOS T MM10 to a fixed surface ATTACH UNICOS T MM10 TO A FIXED SURFACE 85...
Страница 88: ...10 Remove UniCOS F MM 7 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 88...
Страница 90: ...6 7 POWER 2x RJ 8 9 click click 10 INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 90...
Страница 91: ...Remove UniCOS F MM 10 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 91...
Страница 99: ...Figure 1 57 How to detach the nameplate from the mounting bracket and bottom plate MOUNT THE NAMEPLATE 99...
Страница 162: ...TELEVIC CONFERENCE Leo Bekaertlaan 1 8870 Izegem Belgium 32 51 30 30 45 GET IN TOUCH...