Televes avant 7 Скачать руководство пользователя страница 1

Programmable head-end amplifier

EN

User instructions

w w w . t e l e v e s . c o m

Ref. 532840
Ref. 532940
Ref. 532970

Содержание avant 7

Страница 1: ...Programmable head end amplifier EN User instructions w w w t e l e v e s c o m Ref 532840 Ref 532940 Ref 532970 ...

Страница 2: ......

Страница 3: ...ut level configuration 8 IF configuration 8 VHF configuration 9 FM configuration 9 Using the menus Extended menu 10 Status 10 Language selection 10 CDC address 10 Default configuration 11 Unit locking PIN 11 Saving and Adjustment process 11 Configuration Cloning 12 Copy settings Unit Programmer 13 Loading settings Programmer Unit 13 Deleting of settings 14 Error message 14 Using reset button 14 Te...

Страница 4: ... object falls inside the equipment please contact a specialized technician Todisconnecttheequipmentfromthemains pullfromtheconnector and never pull from the cable Do not connect the equipment to the mains until all the other connections have been made The mains socket that is going to be used to connect the equipment should be located nearby and should be easily accessible Description of the elect...

Страница 5: ...s which the user can scroll through by pressing the button and which allow the following functions Configuration of the system s UHF inputs number of filters per input Switching off of the VHF and or FM inputs Select the channels for each filter max 5 consecutive channels per filter Set the UHF output level it determines the VHF and FM levels Set the UHF equalisation slope Set the IF configuration...

Страница 6: ...Menu 1 Input configuration 2 Filter 1 3 Filter 2 4 Filter 3 5 Filter 4 6 Filter 5 7 Filter 6 8 Filter 7 9 Filter 8 10 Filter 9 11 Filter 10 12 Output level configuration 13 IF configuration 2 14 VHF configuration 15 FM configuration 1 There is also an extended menu option which can be accessed from any submenu of the main menu by pressing the button for more than three seconds Once in the extended...

Страница 7: ...ck to the previous value Once the channels of the first filter have been programmed press the button to enter the next filter If you wish to program channels in this filter proceed as we have just seen for the first filter Repeat this step to program all the filters in the Avant If you do not wish to program more channels in the filters you have left to program press the button repetitively until ...

Страница 8: ...esofthemenusuchasAttenuation Equalisation or LNB configuration short press Places the cursor on attenuation Equalisation or LNB configuration long press Enters the extended menu short press Changes to the VHF Configuration menu long press Saving and adjustment Procedure Press the button to activate blinks the option IF Attenuation Use buttons to select the desired value between the possible values...

Страница 9: ... the FM input In Manual Adjustment allows to increase or decrease the level of the filter one dB per press once the filter has already been adjusted automatically short press Places the cursor on the position of the FM filter or on the manual adjustment of the FM filter Offset long press Enters the extended menu short press Changes to the Input Configuration menu long press Saving and adjustment P...

Страница 10: ...ustment Procedure Use buttons to select the desired language of the menus of the display Example Menus selected in English CDC address menu The next menu is CDC Address Allow to increase or decrease each of the three digits of the address between 0 9 The value of the address must be between 001 and 254 short press Places the cursor on the digits to be modified long press Enters the main menu short...

Страница 11: ...u following the same procedure enter code and then confirm with a long press of the button and the unit will be unlocked PASSWORD 0 0 0 0 PASSWORD 0 0 0 0 PASSWORD 6 0 0 0 PASSWORD 6 0 0 0 CONFIG FI Aten 7dB EQ 3dB LNB 13V ON PASSWORD 0 0 0 0 PASSWORD 0 0 0 0 PASSWORD 6 0 0 0 PASSWORD 6 0 0 0 CONFIG FI Aten 7dB EQ 3dB LNB 13V ON PASSWORD 0 0 0 0 PASSWORD 0 0 0 0 PASSWORD 6 0 0 0 PASSWORD 6 0 0 0 P...

Страница 12: ...manual and shown on display Save Mode 11 MODE exit 11 MODE Hotel Plaza save 11 MODE Hotel exit Leaving save mode 11 MODE Avant HD Hotel Plaza exit Operating Mode Device indicator Command Configuration index Configuration Description COPY SETTINGS Unit Programmer LOAD SETTINGS Programmer Unit DELETE SETTINGS ...

Страница 13: ...es Note The language in which the messages and menu are displayed will be the same as that of the connected device If said device does not accept languages they will appear by default in English Loading settings Programmer Unit This menu allows you to load the settings saved in the Universal Programmer to a connected device The keyboard correspondence in this menu is as follows To increase or decr...

Страница 14: ...ered The copy load operation has been aborted The name of the unit can not be recovered The copy operation has not been completed successfully Using Reset button The Avant unit can be programmed before the installation is carried out and without an input signal and the levels can be adjusted later without the use of the programmer by using the reset button located to the left of the programmer s c...

Страница 15: ... 120 120 120 123 Output level regulation dBμV 96 111 86 101 91 106 91 106 96 111 Noise figure dB 9 10 10 9 Rejection dB 20 16 MHz 20 16 MHz 20 16 MHz 40 at 862 MHz Input powering 1 automatic I max V mA 24 13 17 22 KHz 60 300 Mains voltage frequency V Hz 196 264 50 60 Maximum current mA 255 Max power consumption W 26 Max working temperature ºC 45 Weight gr 2 800 Dimensions mm 320 x 258 x 60 Protect...

Страница 16: ...signal levels introduced in the FM 2 BIII input and finally with the verification of the programmed filters The indication that the FM 2 or BIII level is low when we do not apply the signal in these inputs will not affect the rest of the selected channels We must remember that the level indications in the FM 2 BIII inputs and filters shown on the programmer s display are a reference for the adjust...

Страница 17: ...F channels and between 70 74 dBµV for UHF channels thus these channels are adjusted to the same level as the selected filters 196 264V 50 60 Hz 196 264V 50 60 Hz 1 532970 BI FM 2 Available in ref 532840 Ref 4061 Ref 4061 Ref 4061 Ref 543603 Adjust 532840 Ref 5363 UHF1 UHF2 UHF3 FM 1 FI 1 2 BIII DAB 196 264V 50 60 Hz 70 74dBμV UHF FI 2 MATV FI 2 MATV FI 1 2 MATV 7 x QPSK PAL Ref 5537xx 7 x DVB S2 C...

Страница 18: ... force at the time of purchase is applied Keep the purchase invoice to determine this date During the guarantee period Televés S A complies with the guarantee by repairing or substituting the faulty equipment The harm produced by improper usage wear and tear manipulation by a third party catastrophes or any other cause beyond the control of Televés S A is not included in the guarantee ...

Страница 19: ...19 ...

Страница 20: ...532840_532940_532970_000_EN ...