background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

VACUGUARD USER’S GUIDE  

 

 

PORTABLE VACUUM MEASUREMENT 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

TELEVAC 

A DIVISION OF THE FREDERICKS COMPANY 

2400 PHILMONT AVENUE, 

HUNTINGDONVALLEY, PA  19006 

SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

Содержание VacuGuard series

Страница 1: ...ISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVENUE HUNTINGDONVALLEY PA 19006 SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com ...

Страница 2: ...ION 07 TROUBLESHOOTING 08 SPECIFICATIONS 09 UNPACKING INSPECTION 10 WARRANTY INFORMATION PLEASE READ THIS MANUAL THOROUGHLY BEFORE USING THIS INSTRUMENT REPORT ANY PROBLEMS IMMEDIATELY SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com ...

Страница 3: ...rectly in torr or millitorr Overall size is 4 x2 5 x5 5 Instrument weight is 23 oz FEATURES Wireless Portability A replaceable D cell eliminates 110VAC extension cords and their associated safety hazards Rugged Construction Powder coated extruded aluminum enclosure and an available hands free carrying case will go the distance for years of productive service Large Digital Display Bright red LED di...

Страница 4: ...ed in strict accordance with these safety instructions These safety precautions must be observed during all phases of operation installation and service of this product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the instrument Televac disclaims all liability for the customer s failu...

Страница 5: ... are qualified to do so To reduce risk of fire or electric shock do not expose this product to rain or moisture Objects and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Be careful not to spill liquid of any kind onto the products Do not substitute parts or m...

Страница 6: ... compartment Turn the instrument to a vertical orientation and allow the cover to fall into your hand Insert the battery into the compartment with the positive terminal facing toward the rear of the instrument The negative contact plate inside the compartment is spring loaded allowing for battery travel of as much as 0 75 Align the battery compartment cover over the end of the battery so that the ...

Страница 7: ...ll fit the right hand port Note that while the modular plugs are of different sizes the modular plug of the 2A cable will fit either port but will only work properly in the correct right hand port The DV4 DV modular plug will only fit the left hand port If you are planning to use both sensor types be sure to install only one cable at a time Install a cable now SUNSTAR传感与控制 http www sensor ic com T...

Страница 8: ... you are using The reference standard will allow you to verify the correct operation of the VacuGuard Instrument A list of recommended spares and options are noted on Chapter 8 of the User s Guide 0 1000 MICRONS 1 MICRON 34 35 36 998 999 1000 1000 2000 MICRONS 100 MICRONS 1000 1100 1200 1999 2000 2 TORR 2000 MICRONS 20 TORR 0 1 TORR 2 1 2 2 2 3 19 8 19 9 20 0 If the display has a decimal point TOR...

Страница 9: ...hat extends from atmospheric pressure to a region known as very ultrahigh vacuum 1x10 14 torr This total spectrum of measurable vacuum contains about 18 decades of pressure For example The TELEVAC 2A series sensor measure from 20 torr to 1 millitorr Five decades The DV 6 DV 6R sensors measure from 1 torr to 1 millitorr Four decades The DV 4 measures from 20 torr to 0 1 torr Two decades Please real...

Страница 10: ...mation on our family of Miniature 2A sensors It is usually useful to have a known reference to periodically check the instrument and or sensor performance Refer to the information the next page about our expensive reference standards Contacting us Our main telephone number 215 938 4444 and normal hours are 8 00 am to 5 00 pm eastern time Our Fax number 215 947 7464 Our main email address vacuum te...

Страница 11: ...ition Move to correct position see chapter 5 Thermocouple sensor may be defective Test a known good thermocouple sensor or reference standard Entire display or a single decimal point is flashing Indication of low battery power Replace with a new or freshly recharged cell SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic co...

Страница 12: ... battery 23 oz The rate of battery drain is a function of which brand thermocouple sensor is being measured Recommended Options Spares Televac 2A reference standard 0 millitorr P n 2 2100 237 Televac 2A sensor cable P n 2 9800 081 Televac 2A miniature sensor cable NASA type P n 2 9800 082 DV4 DV6 sensor cable P n 1 2400 036 Rechargeable NiCad battery pack of 2 cells P n 1 5400 025 Battery charger ...

Страница 13: ...s to TELEVAC Damage In the unlikely event that the shipping container was damaged in transit carefully inspect the contents for damage If the MV2A Instrument or any of its accessories were damaged in transit contact the freight carrier and tell them you wish to make a damage claim Contact TELEVAC for further instructions on replacement of damaged materials Should any of the above problems be encou...

Страница 14: ...epaid and which our examination should disclose to our satisfaction to have been defective Those portions specifically exempt from this guarantee are gauge tubes batteries as well as meters which have been dissembled or physically damaged The Fredericks Company does not assume any other obligation than that stated in this warranty nor does it authorize any person to assume for them any liability i...