Technical specifications
Downstream signal path ( all values with the diplex filters)
Frequency range
47 / 54 / 70 / 85 / 108..1006 MHz
Return loss
18 dB
Gain
40.0 dB
Input attenuator control range
0...15 dB @ 1 dB
Input equaliser control range
0...20 dB @ 2 dB
Cable simulator
0 / -8 dB
Mid-stage slope
0 dB / 8 dB
Mid-stage gain selection
40.0 dB / 32.0 dB
Flatness
± 0.5 dB
Noise figure
7.0 dB
Output level, CTB CENELEC 42 ch
112.0
dBμV
Output level, CSO CENELEC 42 ch
114
.0 dBμV
Output level, XMOD CENELEC 42 ch
111.0
dBμV
Upstream signal path (return module and diplex filters are installed into the CXE202)
Frequency range
5...30 / 42 / 50 / 65 / 85 MHzMHz
Return loss
18 dB
Gain
28.0 dB
Gain control range (output)
0... -15 dB @ 1 dB
Gain control range (input)
0 / -10 dB
Slope control range
0...15 dB @ 1 dB
Flatness
± 0.75 dB
Noise figure
5.0 dB
Output level, DIN 45004B
114
.0 dBμV
General
Power consumption
14 W
Supply voltage
26
...65 V AC,
180
…255 V AC
Maximum current feed through
3.0 A / port
Input / Output connectors
PG11 (several adaptors available)
Test point connectors
F female (20 dB)
Dimensions (h x w x d)
140 (148) mm x 182 (210) mm x 84 mm
Weight
1.5 kg
Operating temperature
-40...+55 °C
Class of enclosure
IP54
EMC
EN 60728-2
Additional EMC tests for RF ports
ESD 4
kV / Surge
4
kV
All specifications are subject to change without notice